6.15 Define Load Combinations and Envelope │ Design of RCC Building by ETABS │ Akshay Thakur

Поделиться
HTML-код
  • Опубликовано: 7 окт 2024

Комментарии • 46

  • @AkshayThakur
    @AkshayThakur  4 года назад +2

    _If you complete the course, then I'd be happy If you give me the feedback of this course by just filling this google form_ _forms.gle/Q7gUW4untqbBszfs8_

    • @SAQ_records
      @SAQ_records 3 месяца назад +1

      Thanks a lot for the playlist it helps me lot. Can you please share the excel sheet.

  • @abdulqayyum5444
    @abdulqayyum5444 Год назад

    Thank you for your work it helps me enhancing in my knowledge of structure

  • @mohammadtaqiuddin0522
    @mohammadtaqiuddin0522 2 года назад

    Helpfull vedio thank you sir

  • @nehalmehta5155
    @nehalmehta5155 Год назад

    SIR, PLEASE ADD THE LOAD COMBINATION FOR THE NON-ORTHOGONAL BUILDING AS YOU DISCUSSED IN THE LAST SECOND AND OTHER CHANGES.

    • @AkshayThakur
      @AkshayThakur  Год назад

      for non-orthogonal it is 30% earthquake load of ithe4 direction to be add in primary direction of earthquake load combo...

  • @RutuPatel1999
    @RutuPatel1999 4 года назад

    If there is a different height building and shear wall is added to it, then will the same combination load be added to it or will there be some other extras?

    • @AkshayThakur
      @AkshayThakur  4 года назад +1

      same... load combinations depends on type of structure, soil type and building geometry not on structural system.... for seismic analysis.... for IS.1893.1-2016

  • @mohdanas-ey3no
    @mohdanas-ey3no 4 года назад +1

    Sir aapne wind load apply nahi kiya h kya

    • @AkshayThakur
      @AkshayThakur  4 года назад

      I have considered Wind Loads are per IS 875-3:2015
      Lecture 4.3 for Manual Wind Load Calculations
      Lecture 6.11 Application of Wind Load in ETABS

  • @ConstructionTechandVlogging
    @ConstructionTechandVlogging 4 года назад

    Is this load combination can be used for High rise building also or not?

    • @AkshayThakur
      @AkshayThakur  4 года назад

      All the things depends upon building configuration/soil/seismic zone ... for consideration of load combinations
      there are some provisions for considering load combination for seismic analysis for which we need to consider building is orthogonal or not... structure lies in which seismic zone, soil type, etc.... and by.... considering all those factors we need to consider load combinations for particular case i.e., for 30% load in other direction and 30% vertical earthquake effect in same combo as per Cl.6.3 of IS 1893.1-2016
      *also, Consider respective design standard for type of structure (concrete-456/steel-800)

  • @bb-ur2dk
    @bb-ur2dk 3 года назад

    Hi, Akshay Thakur defining 50 design load combinations and 33 service load combinations is a time taking process and there is a possibility of occurring man-made errors I mean typo. are there any other options that make the definition of loads make easier. like can I make the template with these load combinations for repeated use?

    • @AkshayThakur
      @AkshayThakur  3 года назад +1

      Method 1: you can define design load combinations by ETABS itself by Default Design Combo Option but for serviceability you need to define manually... for Indian Standards
      Method 2: copy text for load combination data from existing model by ETABS .e2k text file to your model .e2k file to save the time and within minute you can define all load combinations

  • @ezhilarasan3776
    @ezhilarasan3776 4 года назад

    Sir, is this load combination same for a type of rcc building like regular or irregular.

    • @AkshayThakur
      @AkshayThakur  4 года назад +1

      no, for non-orthogonal building structure load combinations should be as per IS 1893 (Part-1)

    • @ezhilarasan3776
      @ezhilarasan3776 4 года назад

      @@AkshayThakur sir, If i take residential project for structural design( Independent)..Shall i use this method

    • @AkshayThakur
      @AkshayThakur  4 года назад

      i have also metioned in excel sheets as discliamer that it is content is for education use only not for commercial, in real-life project there are many more things you need to consider that i have also not discussed in video lectures mostly about stuctural planning and detailing of structural elements.
      This course is just a part of what actual process that structural engineer do, but not whole ....

    • @AkshayThakur
      @AkshayThakur  4 года назад

      YES, You can use this method; but things i discussed are also not enough ...

    • @ezhilarasan3776
      @ezhilarasan3776 4 года назад

      @@AkshayThakur ok sir..Thanks for rply

  • @manirathinam7222
    @manirathinam7222 3 года назад

    Can we apply wind load and earth quake load at the same time? Doesn't it show any error? Because in STAAD pro we can't assign both the loads at the same time. Am I right? If I'm wrong could you correct me?

    • @AkshayThakur
      @AkshayThakur  3 года назад +1

      you can apply EL & WL load at same time,
      but actually your structural members are going to design for load combinations that what you define and there is no any load combination as per Indian Standard which allow EL & WL in same combination...
      so it is not about how many different loads you applied at a same time but it all depends on which load combinations you use, which actually governs the design...
      basically design is goven through design load combination, and load combination include different loads.

    • @AkshayThakur
      @AkshayThakur  3 года назад +1

      in some case of high-rise buildings wind tunnel analysis is perform and also stiffness modifiers are used as per IS 16700: 2017 to design the tall building structure and design results are compared with seismic dyanmic analysis (Response Spectrum/Time History) and final design is chosen for governing loads...

    • @manirathinam7222
      @manirathinam7222 3 года назад

      @@AkshayThakur thank you so much for the explanation brother...

    • @manirathinam7222
      @manirathinam7222 3 года назад

      How did you create those 50+30 load combinations brother? I can understand you referred it from is456... But how did you make it upto 50+30?

    • @AkshayThakur
      @AkshayThakur  3 года назад +1

      refer table 18 in IS 456:2000, & accordingly for your load cases prepare load combinations for design and serviceability respectively... kept in mind IS 1893 clauses for seismic load combinations for specific cases like building orthogonality and vertical seismic load

  • @uttambaral3515
    @uttambaral3515 3 года назад

    If there is live load greater than 3 KN and under 3 KN in same building. how can we define mass source and how can we define load combination??

    • @AkshayThakur
      @AkshayThakur  3 года назад

      then define two seperate load patterns;
      in load pattern one is for =3kN/m2 and under mass source apply respective factor and for load combination both in should be there where ever Live Load.

    • @uttambaral3515
      @uttambaral3515 3 года назад

      @@AkshayThakur meaning, for example A02: 1.5 (DL+SIDL+LL) can be written as A02: 1.5 (DL+SIDL+LL
      3)

    • @AkshayThakur
      @AkshayThakur  3 года назад

      right, make sure roof live load should be roof live as in load pattern and do not need to include in mass source but needed to include in load combination....
      here in this course i have consider roof live under normal live load pattern.

  • @maheshtelange5132
    @maheshtelange5132 4 года назад

    👌👌👌

  • @debasishghara9487
    @debasishghara9487 4 года назад

    Response spectrum k liya load combination Kaya hoga

    • @AkshayThakur
      @AkshayThakur  4 года назад

      replacement of EL static load case with its dynamic load case but as per soil and structure type all changes needed in combinations as per IS 1893.1-2016

  • @bishalshah2498
    @bishalshah2498 3 года назад

    sir why im not getting access to your excel sheets🙄

    • @AkshayThakur
      @AkshayThakur  3 года назад

      links are working properly, check again... or try to download with another web browser... on chrome i check! its working...

  • @ajazsayyed8487
    @ajazsayyed8487 4 года назад

    Sir for RCC underground water tank design the load combination. Plz tell

    • @AkshayThakur
      @AkshayThakur  4 года назад

      Load Combinations are same as per Design Standard and Provisions of Earthquake Code for respective type of Material... only the thing is for such structures appropriate loads need to be applied carefully...

    • @ajazsayyed8487
      @ajazsayyed8487 4 года назад

      @@AkshayThakur plz tell me about earth pressure and water pressure load combination in is code

    • @AkshayThakur
      @AkshayThakur  4 года назад

      go through IS 3370... for Indian Standard Provisions....

    • @ajazsayyed8487
      @ajazsayyed8487 4 года назад

      @@AkshayThakur thank you so much.

    • @AkshayThakur
      @AkshayThakur  4 года назад +1

      IS 3370 is for requirements for structural design, you need to follow IS 456 for concrete design... same for load combinations.... if you are doing analysis and design in ETABS then for soil pressure and water pressure you need to define spefic different load patterns and apply the load through this procedure....