standard air conditioner modification (1 outdoor 2 indoor)

Поделиться
HTML-код
  • Опубликовано: 10 сен 2024
  • AC (Air Conditioner) air cooler
    Because the electric power in the house is lacking and the rooms need more power, the idea was sparked to modify the air conditioner, for those who imitate and have problems with the air conditioner, please bear your own risk
    overcoming power shortages
    reduce electricity consumption
    #sharp, LG, samsung, panasonic, media
    daikin, polytron
    #cold room without ac
    #how to cool the room
    #new discoveries in air conditioner
    #makes the air conditioner cooler
    #how to make a two head air conditioner
    #one outdoor uses for two rooms
    1ac uses 2 rooms
    #how to modify ac
    an easy way to change the air conditioner into two indoor
    AC 2 indoor 1 outdoor
    Make the evaporator corrosion resistant
    let it not hit the salt water

Комментарии • 120

  • @ariffira5129
    @ariffira5129 7 месяцев назад +1

    D seri y ,harusnya d paralel d kasih selenoid valve ,biar kalau hidup 1 yg 1 lg walaupun kondisi mati itu ga beku evapnya ,

  • @TiaOktaviani-hg7xm
    @TiaOktaviani-hg7xm Год назад +1

    Pake selenoid.. Biar ac a di matikan ac b berpungai dwngan baik

  • @taufiqfirmansyah3744
    @taufiqfirmansyah3744 Год назад +2

    Mantap, sudah di coba pake Ac di rumah pakean sendiri. Alhamdulillah sudah bertahan 1 th lebih aman. Terimakasih

    • @sanjayamei8529
      @sanjayamei8529 6 месяцев назад

      Tekanan manipol brp mas.. Klo r32

    • @Acmataram
      @Acmataram  6 месяцев назад

      Freon apapun jenisnya tinggal di cek di evaporator apa sudah rata dinginnya dan tidak boleh lebih dari ampere outdoor yang di pake

    • @jaguarchannel2576
      @jaguarchannel2576 6 месяцев назад

      Mas mau tanya sala satu indoor yg di hidupkan indor 1 nya evaporator tetap dingin ya

    • @Acmataram
      @Acmataram  6 месяцев назад

      @@jaguarchannel2576 tetap tapi tidak bunga es

    • @adetandra4027
      @adetandra4027 4 месяца назад

      ​@@Acmataramizin om. Penyambungan kabel power a sama b paral biasa. Untuk kabel ke outdoor sama pararel biasa. Jika dua2nya sama2 mengirim strum ke outdoor apa gk jadi masalah ya om? Masih kurang paham di sini. Makaaih om. Moga dijawab

  • @hendrahananta5310
    @hendrahananta5310 2 года назад +3

    mau tanya pak.prinsip dasar ac kan karena perubahan tekanan zat freon dari tekanan high presure menjadi low pressure,trus yg keluar dari ac A berapa psi? dan apakah kompresor nggak jebol,klu dikasih 120 psi trus high pressure apa nggak di 400an psi pak.

    • @Acmataram
      @Acmataram  Год назад

      Ac menjadi di luar standart pabrikan, biar setandart di ikuti petunjuk pemasangan dari masing2 merk saja

  • @Tontontonan
    @Tontontonan 8 месяцев назад +1

    Pak, itu indoor A pipa besar masuk ke indoor B pipa kecil yah.

  • @ahmadsolihin1975
    @ahmadsolihin1975 Год назад +1

    Untuk ac 3/4 dengan menggunakan freon R32 apakah bisa dirangkai seperti ini...

  • @Ellasarah_24
    @Ellasarah_24 10 месяцев назад

    Mantap bang hasil nya

  • @nazacom2152
    @nazacom2152 2 месяца назад

    Woww mantul bang, boleh ditiru nih... Itu pipa indoor ke indoor hanya satu dari pipa kecil ke pipa besar ya.
    Freon 120psi bener R22 atao R32 bang. Dan ampere jadi brp ya.. Trimakasih.. 👍🙏

    • @Acmataram
      @Acmataram  2 месяца назад

      Sesuaikan aja dengan ampere outdoor freon pake aslinya di nempled outdoor aja

  • @erisrestiawan9818
    @erisrestiawan9818 Год назад +2

    maaf mau tnya,klo seandai nya yg hidup 1 indoor aja,apakah yg indoor 1 nya LG nggak ngeblock mas??

    • @Acmataram
      @Acmataram  Год назад +2

      Enggak kan sudah di salurkan dinginnya di indoor sebelah

  • @rahmatmetaldetektorpalopo
    @rahmatmetaldetektorpalopo 2 года назад +1

    Mantapp👍

  • @ahdiatmargana1053
    @ahdiatmargana1053 2 месяца назад

    Panjang pipa itu berapa??total sememua...jadi lebih pendek ya?

  • @suparhan121
    @suparhan121 2 года назад

    Buat vidio yang lebih jelas lagi om. Trutama di rangkaian klistrikannya.

    • @Acmataram
      @Acmataram  2 года назад +1

      Terimakasih sarannya

  • @user-wd7my6hh2f
    @user-wd7my6hh2f 8 месяцев назад

    Mau nanya pak saya tukang ac belum pernah coba
    Slama ini biasa orang indoor 1 di pake buat 2 kamar.. Menurut saya kurang maksimal dingin nya
    Nah klo indoor masing 2 ac oudoor 1 apakah berasa dingin ruangan nya..
    Pertanyaan saya klo kabel di paralel begitu klo ac 1 mati apalah yg ac 2 nya jdi ikut mati.. Trus klo nyala ac 1 aja apakah ac yg ke 2 nya aman aja klo lagi enggak nyala.. Mohon maaf minta jawaban nya pak

    • @Acmataram
      @Acmataram  8 месяцев назад

      AC tidak saling mempengaruhi hidup matinya, AC yang sedang mati aman dan ada yang komen di bawah sudah nyoba pake di rumahnya dan begitu pula saya sudah mencobanya

  • @idhamsyaiful6024
    @idhamsyaiful6024 День назад

    Gan mau tanya kalau power indor ke outdornya cuma 1 ac bisa gak? Tanpa harus paralel a dan b

  • @suryaputra1411
    @suryaputra1411 10 месяцев назад

    prinsip kerjanya indor A di anggap seperti pipa pressure ya kak, sedangkan hisapnya pakai di indoor B?

  • @nikohutama1492
    @nikohutama1492 Год назад

    Mohon pencerahannya bang. Saya pasang begini. Ac B nya tak dingin . Dan pipa besar (3w tak dingin. .tpi pipa kecil (2w nya) dingin
    Sedangkan ac A dingin .

    • @Acmataram
      @Acmataram  Год назад

      Sesekali baca komen penonton. Disana banyak solusi, sesuikan amper dari unit outdor yang dipake kemungkinan besar freon kurang isi

  • @adyyanwar7123
    @adyyanwar7123 2 года назад +1

    Gan saya mau tanya,saya pasang AC seperti yg di video,tapi ko yg indoor B gak dingin ya,dan begitu yg indoor B di hidupkan,tekanan freon malah naik,di kompresor juga malah seperti ada air mengalir

    • @Acmataram
      @Acmataram  2 года назад

      Cara isi freon, hidupkan AC A dan B perhatikan Apere, isi freon sampai pipa balek dingin, kalau saya jarak antara A dan B kurang lebih 3 M dan A dan B lebih dingin A, operasikan unit A dengan kecepatan kipas rendah jangan lupa di vakum menggunakan mesin

  • @princessalika2112
    @princessalika2112 Год назад

    Apa bisa dingin ac outdoorx cm ½ pk, trus melayani indoor 2 unit...., .1 unit sj indoornya blum tentu dingin apalg buat 2 unit....

    • @Acmataram
      @Acmataram  Год назад

      Anda cek saja komentar nya Agoes Suhermanto

  • @hasyimponty38
    @hasyimponty38 Год назад

    Maaf, penyambungan kabel yg di vedeo ini, ketika AC indoor A di matikan saya rasa AC indoor B juga ikut mati, bukan begitu ya pak ?

    • @Acmataram
      @Acmataram  Год назад

      Di matikan pake rimut atau cabut cok ?

  • @meganzidan711
    @meganzidan711 Год назад +1

    Sistem kerja termistornya gimana pak

  • @tirtadamarkrisna8683
    @tirtadamarkrisna8683 2 года назад +1

    Sekema pipa gimana om... Apa unit A keadaan off freon tetep sirkulasi di unit A

    • @Acmataram
      @Acmataram  2 года назад

      Betul tetap sirkulasi, sekema pipa seri

  • @sanjayamei8529
    @sanjayamei8529 6 месяцев назад

    Untuk kompresorny gmn mas.. Aman gak..

  • @dedealunk4245
    @dedealunk4245 2 года назад +2

    Apa ga ngefreeze tuh klo indornya hanya dinyalakan 1 unit aja, misalkan indor a mati yg hidup indor b otomatis freyon melewati indor A, atau sebaliknya, kan fan salah satu mati?
    Maaf klo salah dalam penulisan dan maaf hanya bertanya soalnya ga paham AC,
    Terimakasih

  • @panjitoto2035
    @panjitoto2035 2 года назад +2

    kalo yg ini kan di seri

  • @nanangharun
    @nanangharun 3 месяца назад

    Om panjang pipa ac 1 dan 2 gimna

  • @jovanerico1251
    @jovanerico1251 Год назад

    Om tanya saya udah pasang ac seperti video ac semua dingin dan bisa di matikan masing masing indoor bisa mati.masalahnya ..ac saya indoor mati semua tapi outdoor hidup terus dak mati kira kiraasalahnya dimn ya makasih

    • @Acmataram
      @Acmataram  Год назад

      Klu sdh bener kabel di pasang angka 1 di ac a disatukan dengan 1 ac b dan 2 juga di satukan, dan masing2 power yang coklat masuk pase, ke mungkinan salah satu reley di modul indoor bermasalah

    • @jovanerico1251
      @jovanerico1251 Год назад

      Makasih nanti cek ulang

  • @unhyyanti3960
    @unhyyanti3960 Год назад

    Kira2 kompresor AC tdk cepat rusak ...
    Terus pendinginan suhu maksimal ap tdk

    • @Acmataram
      @Acmataram  Год назад

      Bisa maksimal dengan catatan harus sesui besar ruangan dengan PK/BTU yang di gunakan

  • @jokosutopo9196
    @jokosutopo9196 3 года назад

    Mau tanya kk, brrti rangkaian pipa n kabel cukup diparalel ja ya kk??
    Trs klu seumpama indor pake 1pk n kedua outdor msg2 0,5pk aman g kk

    • @Acmataram
      @Acmataram  3 года назад

      Pipa seri, kabel pararel dan masalah indoor aman

    • @jokosutopo9196
      @jokosutopo9196 3 года назад +1

      Ok mksh byk kk ilmunya

    • @panjitoto2035
      @panjitoto2035 2 года назад

      @@Acmataram om mua tanya itu di seri,
      kalo di paralel bisa juga nga om,
      kira2 dingin nga

    • @Acmataram
      @Acmataram  2 года назад +1

      @@panjitoto2035 bisa cuman harus hidup keduanya klu hidup satu dia timbul bunga es yg tidak hidup

  • @bambangtembong7457
    @bambangtembong7457 2 года назад

    Kurang Jelas..coba di gambar
    .biar jelas

  • @dewakeren118
    @dewakeren118 7 месяцев назад

    bng ac indor a kurang dingin dan pipa kurang bacah evvapnya ac b dingin evab basah dan

    • @Acmataram
      @Acmataram  7 месяцев назад

      Pada waktu pengaturan jumlah freon Berpedoman sama dingin evaf yang rata dan batas Amper di nenplate

  • @herususanto4544
    @herususanto4544 2 года назад

    Konsumsi arus outdoor berapa bang? Lihat di tekanan magnifold koq sampe 120psi

  • @oemahcinema4623
    @oemahcinema4623 2 года назад +1

    Lokasi mana pak. Bisa diwilayah sukoharjo jateng

  • @maul3391
    @maul3391 2 года назад

    Pak .tanya boleh ya.itu outdoornya ga ada yg di rubah ya atau di modif modulnya gituh.jadi cuman modal pipa sama solasi aja. Trua untuk setengah pk dengan 2 indor di isi prionya brpa yaa.

    • @Acmataram
      @Acmataram  2 года назад

      Tidak ada dirubah, sesuikan ampere aja

  • @mamaspuput8860
    @mamaspuput8860 Год назад

    dalam kondisi 1 ac yang menyala, maka ac yang lain beku dan menetes?

  • @wikafikaakbar4088
    @wikafikaakbar4088 2 года назад

    Itu kapiler apa merubah ukurannya atau ukurannya sama cuman kapiler d gandakan

  • @winataerick6645
    @winataerick6645 2 года назад +1

    Jadi sistemnya pipa besar ketemu pipa kecil gitu ya mas

  • @muhammadsuaidi4105
    @muhammadsuaidi4105 10 месяцев назад

    Pemasangan pipanya dari indor 1 ke indor 2 diseri ya?

  • @mohammadnopal1056
    @mohammadnopal1056 3 года назад

    Andaikala hanya menghidupkan indoor 1saja, apakah bisa dingin?

  • @nikohutama1492
    @nikohutama1492 3 года назад

    Tambahan bang .berarti indoor di hidupkan 1 dan satu lagi automatis hidup lah ya bang?

    • @Acmataram
      @Acmataram  3 года назад

      Tidak otomatis hidup

  • @goesochalucky7577
    @goesochalucky7577 3 года назад

    tanya pak,kisaran brp biaya utk 1 pk outdoor, 2 indoor? makasi

    • @Acmataram
      @Acmataram  3 года назад

      Tergantung daerah karna indoor yang sebelah pake indoor bekas

  • @rachmadsutrisno6773
    @rachmadsutrisno6773 Год назад

    Ada nmr WA nya kah..yg bisa dihubungi kalau mo pasang daerah cileungsi

  • @baskorobas7550
    @baskorobas7550 Год назад

    Pipa kapiler dirubah juga....??

    • @Acmataram
      @Acmataram  Год назад

      Tidak di rubah tetap aslinya

  • @putuadi3904
    @putuadi3904 2 года назад

    Klau mati satu indoor y ada masalah kan sama aoutdoor y

    • @Acmataram
      @Acmataram  Год назад

      Enggak masalah, saya pake sendiri dengan sistem ini

  • @noerachamadfauzi1570
    @noerachamadfauzi1570 Год назад

    lah..ko gk pake Celenoid Valve pak,, gmn jd'nya ?🙄

    • @Acmataram
      @Acmataram  Год назад

      Di coba aja, saya memanfaatkan dinginnya pipa penghubung

  • @adekimut9610
    @adekimut9610 2 года назад

    Jika indor satunya mati apa gk beku efaf yaaaaa

  • @hiburanaja774
    @hiburanaja774 Год назад

    Kalau R32 tekanan freon brp gan

    • @Acmataram
      @Acmataram  Год назад

      Belum pernah nyoba untuk R32, disesuaikan aja ampere nya

  • @abulqasimimbaya8342
    @abulqasimimbaya8342 Год назад

    Of you can please translate the video tutorial into English i wud be pleased sir! thanks

    • @senyastriyani1336
      @senyastriyani1336 Год назад +2

      You can use google voice for translate to your language. Voice language Indonesia

    • @Acmataram
      @Acmataram  4 месяца назад

      Sudah saya buatkan

  • @nikohutama1492
    @nikohutama1492 3 года назад

    Logika sederhana ya mantap.
    Cuman kalau gtu apakah gada masalah tu bang ? Dari kompresor nya karna dia 1 relay di outdoor .tpi indoor nya 2

    • @Acmataram
      @Acmataram  3 года назад

      Saya sudah menggunakan untuk pribadi selama 5 tahun

    • @agoessuhermanto6750
      @agoessuhermanto6750 Год назад +1

      Aman saja sya sudh memprakteknya berulang kali hasilnya mantap

    • @nikohutama1492
      @nikohutama1492 Год назад +1

      @@agoessuhermanto6750 thx infonya. Saya akan coba

    • @wawanwawan7472
      @wawanwawan7472 8 месяцев назад

      Mantaf

  • @mks240381
    @mks240381 3 года назад

    di makassar ada ngak?

  • @ridwanridae7176
    @ridwanridae7176 Год назад

    Bang 1/2pk dan 3/4pk pakai 1outdoor 3/4 bisa ya? Dan mana dulu yang jadi inlet dan outlet nya?.semoga lekas di jwb trimakasih

    • @Acmataram
      @Acmataram  Год назад

      Boleh 1/2 sampai 1 pk , inlet atau outlet boleh aja yg 1/2 atau 3/4 dibolak balek

  • @ponsbob5231
    @ponsbob5231 Год назад

    Jarak maksimal dari indoor A ke B berapa meter pak ?

    • @Acmataram
      @Acmataram  Год назад

      Saya belum pernah sampai menganalisa sampai di sana

    • @ponsbob5231
      @ponsbob5231 Год назад

      Jarak Indoor A & B 5 meter..masih dingin ga pak ?

    • @Acmataram
      @Acmataram  Год назад

      Kebetulan punyak saya 5 meter jaraknya

    • @ponsbob5231
      @ponsbob5231 Год назад

      Bisa ya pak..jarak indoor A & B 5 meter beda ruangan..masih normal pendinginannya..🙏
      Trims infonya.

    • @ponsbob5231
      @ponsbob5231 Год назад +1

      Kalau hanya 1 indoor B yg hidup, ruangan A akan dingin juga ya wlwpun kipas indoor A ndak nyala apa tidak beku yg A..pak ?

  • @panjitoto2035
    @panjitoto2035 2 года назад

    kalo di paralel gmn om bisa nga ya

  • @yatnoplenti2797
    @yatnoplenti2797 Год назад

    alamat benkel dimana pak?

  • @aboamina695
    @aboamina695 2 года назад

    سلام بالنسبة لكمية الغاز هل تزيد ام تبقى كما هي

    • @Acmataram
      @Acmataram  2 года назад +1

      Di sesuaikan aja ampere atau konsumsi listrik dari unit outdoor yang dipake

  • @panjitoto2035
    @panjitoto2035 2 года назад

    kalo outdor 1,5pk pake indor 2 unit bisa nga om