pH 700

Поделиться
HTML-код
  • Опубликовано: 7 ноя 2024

Комментарии • 21

  • @hindilearningcenterlearnhi91
    @hindilearningcenterlearnhi91 2 года назад

    Thank you for explaining. In our case calibration point not detected. How to resolve the issue

  • @MegaAlysia
    @MegaAlysia 2 года назад

    I do not have an ATC probe. Will it work for pH tests?

  • @nidhikumari4278
    @nidhikumari4278 4 года назад

    Nicely explained. Thanks a lot.
    But what if the electrode has less efficiency i.e. slope range is less than 90%. How can we increase the slope range from let's say 85% to 98%?

    • @andylownav285
      @andylownav285  4 года назад

      Slope issues & how to overcome it
      The % obtained can tell you if the slope is good. It should between 92-102%.
      If the slope is not within expectation, User may recheck again as below:
      • Temperature probe : Is the customer using a temperature probe. Because temperature can influence the pH values. (See attachment)
      • Buffer issue: Identify which buffer mV value is not within expectation. Change a different lot/batch
      • Electrode contamination: Clean the electrode with the appropriate cleaning method. Flush and refill a new batch of fill solution in the electrode.

  • @Thehighbramhan
    @Thehighbramhan 10 месяцев назад

    Informative 👍

  • @pramodmokhade1280
    @pramodmokhade1280 2 года назад

    Very Useful video..

  • @sufiyaseen2294
    @sufiyaseen2294 3 года назад

    what to do if PH electrode is turned brownish inside

  • @instrumentationknowledge1373
    @instrumentationknowledge1373 3 года назад

    Very Very easily Calibration
    Thanks 😊 🙏 😊

  • @sunnykumar-my7gl
    @sunnykumar-my7gl Год назад

    If error occurre due to slp then

  • @krish_krish354
    @krish_krish354 Год назад

    How to change ph 9 insted of 10

  • @mongji1022
    @mongji1022 4 года назад +2

    Good video!! 👍🏻👍🏻 It helps a lot

  • @krish_krish354
    @krish_krish354 Год назад

    Well done

  • @MegaAlysia
    @MegaAlysia 7 месяцев назад

    Please provide the catalogue number for this meter.

    • @MegaAlysia
      @MegaAlysia 7 месяцев назад

      And the pH electrode order number.

  • @instrumentationknowledge1373
    @instrumentationknowledge1373 3 года назад

    My dear sir
    Please make one video on BTG consistency transmitter.
    Thanks

  • @ningningzhou5528
    @ningningzhou5528 4 года назад

    Very helpful!

  • @sekharbabu4678
    @sekharbabu4678 4 года назад

    What about slope

    • @andylownav285
      @andylownav285  4 года назад +1

      Slope issues & how to overcome it
      The % obtained can tell you if the slope is good. It should between 92-102%.
      If the slope is not within expectation,
      User may recheck again as below:
      • Temperature probe : Is the customer using a temperature probe. Because temperature can influence the pH values. (See attachment)
      • Buffer issue: Identify which buffer mV value is not within expectation. Change a different lot
      /batch
      • Electrode contamination: Clean the electrode with the appropriate cleaning method. Flush and refill a new batch of fill solution in the electrode.

    • @sekharbabu4678
      @sekharbabu4678 4 года назад

      @@andylownav285 k thank you sir, when slope is below 92% is calibration is passed or not

    • @sekharbabu4678
      @sekharbabu4678 4 года назад

      And also tell buffers acceptable ratio

  • @totalknowledge9823
    @totalknowledge9823 Год назад

    I am sure you are a female because your hand is so beautiful like a girl