During treatment of vertical surfaces of backfilling at masonry surface, ATT should sprinkle directly on masonry before back filling or ATT should be applied on soil near masonry surface after backfilling?
Plan area ke case main kitna litre per sq meter consider kare for example if mera construction area 43 meter x 34 meter hai jo ki 1462 sq.mt ho gaya.To kitna litre "Chlorophyriphos/Lindane emusifiable concentra of 20%" required hoga? What is the formulae for this?
Dear sir , thanks for the video , i have some doubts regarding the ratio of 1:19 from which is code you have taken .... is 6313- i or 6313-ii .. kindly suggest .
Sir mesonary &concrete both case me verical face ,(top 500 in case of concrete) 7.5 ltr per m2 se dalna h but area 7.5 m2 kese nikalenge I mean 7.5 liter kitne running meter me dalenge &kese dalenge please isko samjhao
Sir opc or ppc dono ciment may ghar bnane k liye kon sa accha hai Or dono may water ciment concrete ratio same hai ya alag...alag hair plz.. btaye jarur
Please comment if you have any questions /query. Thanks
what is the name of that chemical
Sir, aapne bahut achche se ATT ke bare me bataya with IS code detail, Thank u sir 🙏
Super sebhi uper 🔥
Good detail for civil site engineer, thank you sir for providing this valuable video
What a clarification sir. I need this information .Thank you for making this video
Aapka har topic fresh rehta hoon
Thanks for appreciating
Apni sari video baht achi h, thx
Narayan Bless 🙏 You
Now my concept clear about ATT thank you sir 👌
Very good video, concentraion of chemical concept is very good.
Thanks sir
Really good explain with reference .
Mast video sir, with full detail
السلام علیکم سر جو کیمیکل اپ نے بتایا ہے کیا یہ گھر بننے کے بعد بھی استعمال کرسکتے ہیں
Good Information sir....
Nice video sir tq
Thank you so much sir
During treatment of vertical surfaces of backfilling at masonry surface, ATT should sprinkle directly on masonry before back filling or ATT should be applied on soil near masonry surface after backfilling?
Major part applied over brick wall surface
TqPlease explain about the coatacion
Sir aap jis book se reference de rhe ho uski copy mil sakti hai kya pls...
Brother?
RCC retaining wall ke baare me btayein... Anti termite ke bare mein... Yadi besment ho tab???
Thank You Sir......
Sir it is said that chemical for surface is 5liter/square meter . This chemical (5 liter) is chemical concentrate or after dillution (1:19)
سر یہ کیمیکل پانی میں مکس ہو کے پڑا رہے تو یہ ضائع ہوتا ہے یا نہیں
Tq bhai
Sir,kindly prepared a vedio on construction welding as per Is standard 9417
Plan area ke case main kitna litre per sq meter consider kare for example if mera construction area 43 meter x 34 meter hai jo ki 1462 sq.mt ho gaya.To kitna litre "Chlorophyriphos/Lindane emusifiable concentra of 20%" required hoga?
What is the formulae for this?
Dear sir , thanks for the video , i have some doubts regarding the ratio of 1:19 from which is code you have taken .... is 6313- i or 6313-ii .. kindly suggest .
Imedacloprid 30.5 %sc
210 ml chemical in 100 litter water me milate h to concentration kitne % bante h
Sir mesonary &concrete both case me verical face ,(top 500 in case of concrete) 7.5 ltr per m2 se dalna h but area 7.5 m2 kese nikalenge I mean 7.5 liter kitne running meter me dalenge &kese dalenge please isko samjhao
sir my query is for pcc ,we should at least use m 15 not m 10 ,thanking you and regards.
Sir plinth protection to poorey periphery may hogi
Sir plinth protection may7.5 l chalega aur sir periphery may apnay kaha ki 150 c/c hole hogaya yeah ni smj aya
Sir opc or ppc dono ciment may ghar bnane k liye kon sa accha hai
Or dono may water ciment concrete ratio same hai ya alag...alag hair plz.. btaye jarur
Opc 43 is best OR you can use ppc cement but curing ko proper karna, water cement ratio are same @ 20-22 litre per bag for 1:2:4 / 1 : 1.5 : 3 ratios
Sue vertical surface me area kese nikalenge
What is name of second chemical.
Post construction
SIR please reply in which IS code it is written the material and chemical and percentage of mixing as I have checked in IS 6313 PART 2 .regards
Details are according to cpwd specifications
@@FactualCivilEngineering Thanks again SIR
The latest Is imidacloprid 30.5% with mix of 2.1ml in 1 liter of water. Can anyone reply if they’ve used? If so which brand?
Paxton 30.5%sc
Bayer premise best
தமிழ்நாட்டில் இதுபோன்ற கரையான் ட்ரீட்மென்ட்டிற்கு கமெண்ட்டிற்க்கு கீழே செல் நம்பர் பதிவிடவும்.
9962251984
9962251984
Sir Ji. Apka koi contect number mil sakta h sir Ji.
Sbse bekar h terminator bhot br use Kia dimk nhi gyi