THE DINING ROOM AC JUST SHUT OFF

Поделиться
HTML-код
  • Опубликовано: 28 авг 2024
  • Sometimes I have to call in other trades to help out, this was one of those times!
    HVACR VIDEOS MERCH WEBSITE - www.hvacrvideo...
    Please consider supporting my channel by
    Becoming a Patreon member - Patreon / hvacrvideos
    Becoming a RUclips channel member / @hvacrvideos
    By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total purchase (exclusions apply)
    Visiting my website and purchasing merch www.hvacrvideo...
    HVAC OVERTIME CHANNEL LINK - / hvacovertime
    Social Media
    Facebook / hvacr-videos
    Instagram / hvacrvideos
    For any inquiries please contact me at chris@hvacrvideos.com
    Mailing Address
    HVACR VIDEOS
    12523 LIMONITE AVE.
    440 - 184
    MIRA LOMA, CA. 91752

Комментарии • 185

  • @FrNMGuy
    @FrNMGuy Месяц назад +112

    That's when you don't pray, "1 2 3, please don't blow up."

  • @neonhomer
    @neonhomer Месяц назад +85

    I had to do a LOTO "check-out" at work, and when I went to turn the power back on (it was a simulated panel, no HV), without thinking I said "1, 2, 3... please don't blow up..." look on my boss & safety guy's faces....😮

  • @Riyame
    @Riyame Месяц назад +50

    2:25 This is the LockPickingLawyer and today I have a perfect example of manglements idiocy.

    • @LadyAnuB
      @LadyAnuB Месяц назад +14

      So how many channels do we viewers overlap with the LockPickingLawyer?
      Also, there was no "Nothing on 1, Nothing on 2…" 😅

    • @Riyame
      @Riyame Месяц назад +9

      @@LadyAnuB Funny part is I met him on the lock forums before he was the LPL. It has been interesting to see him go from where he started to where he is now.

    • @nrs135
      @nrs135 Месяц назад

      Beat me to it 😄

    • @tannerparson7030
      @tannerparson7030 Месяц назад +1

      Percussive persuasion tends to work with those cheaper locks

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC Месяц назад +51

    That J-box identified as a fireworks stand....and let ALL the smoke out

    • @PuddinJr1993
      @PuddinJr1993 Месяц назад +1

      Ain't no way to put the smoke back in 🤣

    • @tbelding
      @tbelding Месяц назад +1

      Gender reveal party.

  • @stevenmilburn6795
    @stevenmilburn6795 Месяц назад +36

    Cya rewire the whole thing dont trust those wires. I agree a home run durect to the unit is best

  • @TooManyHobbiesJeremy
    @TooManyHobbiesJeremy Месяц назад +24

    Congrats for going above & beyond by cleaning up the other contractors mess ❤

  • @AKStorm49
    @AKStorm49 Месяц назад +6

    Two videos that required sparkies in a row. I'm glad to have them in the facility I'm working in now.

  • @The98deville
    @The98deville Месяц назад +51

    Bet that made noise

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад +26

      For real… it straight melted the roof from the molten metal

    • @thomasvlaskampiii6850
      @thomasvlaskampiii6850 Месяц назад +8

      ​@@HVACRVIDEOSThat plasma is ✨ spicy ✨

  • @Joshuatimmons1783
    @Joshuatimmons1783 Месяц назад +25

    That was funny when he showed the mess in the video and said no comment classic electricians leaving a mess at least they cleaned up all the wire

    • @TheChipmunk2008
      @TheChipmunk2008 Месяц назад +13

      yeah because that's worth money.... as a sparky it makes me mad to see slapdash electrical work. Using the red wire taped green as the ground? What kind of sparky hasn't got earth/ground wire on the van ffs

    • @Joshuatimmons1783
      @Joshuatimmons1783 Месяц назад +1

      @@TheChipmunk2008 yeah and some use all black wire and electrical tape as the phase colors

    • @Casal70
      @Casal70 Месяц назад

      The difference between a mouse and an electrician is the color of the leftover belongings.

    • @TheChipmunk2008
      @TheChipmunk2008 Месяц назад

      @@Casal70 sadly in many cases that's true

    • @TheChipmunk2008
      @TheChipmunk2008 Месяц назад +3

      @@Joshuatimmons1783 to me that is fine, but... taping a red as the ground, HELL tgo the no

  • @matcha6842
    @matcha6842 Месяц назад +13

    That was some Kentucky fried wire. Extra crispy recipe.

  • @mbainrot
    @mbainrot Месяц назад +9

    1:32 - What happened here?
    I'd say angry pixies went BRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRR, and that hole in the side of the box was them overflowing out and spilling onto the roof

  • @CBultmann
    @CBultmann Месяц назад +4

    I have the same Fieldpiece clamp meter and rotation check function works great, no need to bump a contractor to see if a fan or pump goes the right way.

  • @gerhardjanen7583
    @gerhardjanen7583 Месяц назад +9

    Hey, I'm not a HVACR tech, but I'm very interested in your doing. Your mindset and your "Big Picture " thinking, helping me chance my mindset, as an service tech for tube bending machines, to become a better service tech. Thanks for all your inspiration.

  • @carloshilarionvazquezaranda
    @carloshilarionvazquezaranda Месяц назад +2

    Muy buenísimo trabajo mi estimado Chris, así es como resuelves los problemas y además das mucho más de ti, no importa quien haga el desorden lo importante es tener la satisfacción al dejar siempre limpio la zona donde trabajamos. Gracias por siempre dar consejos de como hacer nuestro trabajo. Saludos desde Coacalco Edo de México.

  • @leviweltin1163
    @leviweltin1163 Месяц назад +4

    The last two vids have been absolute humdingers!

  • @Skid6660
    @Skid6660 Месяц назад +7

    Great extra argument for your general "stop and observe" approach to trouble calls. Not everything that's let the smoke out is dead.

  • @justme5384
    @justme5384 Месяц назад +14

    To open a Masterlock you just need to use another Masterlock... 2:26

  • @throttlebottle5906
    @throttlebottle5906 Месяц назад

    zappy zap zap, that would have been one heck of a fireworks and lightning show. 🤣

  • @nicolaslab1814
    @nicolaslab1814 Месяц назад +7

    Wow, 2 consecutive videos where the wire goes see ya and a new feed needs to be pulled. Great video as always!

  • @htroberts
    @htroberts Месяц назад +24

    WHY on earth didn’t they just pull the extra eight feet of wire to not need those joints? and why a red wire for ground (not legal)? can’t believe they left that switchboard open and left for lunch…

    • @LastSlovenian
      @LastSlovenian Месяц назад +6

      It's a wild guess, but terminations from solid to flex conduit may need to be accessible. Equipment was installed post electrical works or it blew the wires before and they shortened the whole thing.

    • @quietone610
      @quietone610 Месяц назад

      As long as the electrician marks the ENDS in the correct color, the wire can be whatever is cheaper. Same goes for Orange (high leg of a center-tap Delta config.)--identify at both ends and use whatever you want in the middle--usually.

    • @adamwakefield2831
      @adamwakefield2831 Месяц назад

      ⁠@@quietone610 on on ungrounded conductors you can re identify however grounded and grounding smaller then 4awg cannot be remarked

  • @DeclanBirmingham
    @DeclanBirmingham Месяц назад +1

    I appreciate that you explain everything in each video so the viewer can join your channel at any time and learn something. Thanks

  • @Ksweetpea
    @Ksweetpea 26 дней назад +1

    Look at all that charred wire, its a miracle the building didnt catch fire

  • @rykerthomasj3087
    @rykerthomasj3087 Месяц назад +3

    Don’t know if you’ll answer this question or not, having an issue with the AC in my workplace, it’ll be nice and chilly in the morning, but as the day goes on it comes out the vent at 85+F but if you take thermostat off wall for a few minutes and put it back on vent temp goes back down to 50-60s. The fan stays on the whole time but compressor does not.

  • @timparsons7348
    @timparsons7348 Месяц назад +12

    Well if it's before the load side of the disconnect, it's time to call Sparky.

  • @axelbostrom3606
    @axelbostrom3606 Месяц назад +9

    If there is one thing I know about electricians, it is that they do not clean. The justification I usually hear is that their hour is more expensive than to get the cleaners to do it. How true that is, I don't know

    • @tweake7175
      @tweake7175 Месяц назад +1

      i have always offered to clean the site, but i never once had a customer wanting me to do it.

  • @alext424
    @alext424 Месяц назад +3

    That has to be the worst electrical failure I’ve seen on your channel so far. Thanks for the awesome video Chris! 👍🏻

  • @XeonProductions
    @XeonProductions Месяц назад +4

    Good call not trying to salvage that existing wire, that stuff was charred to a crisp.

  • @kg4muc
    @kg4muc Месяц назад

    Dang! Those wasps were way more docile than usual! Glad you didn’t get stung

  • @youtubeaccount931
    @youtubeaccount931 Месяц назад +7

    One time my good friend opens the box and there was a large rattle snake wrapped around the bus bars LOL! Crispy obv

  • @DocNo27
    @DocNo27 Месяц назад +1

    I love how the original electricians left a loop of plenty of extra cable in the unit going to the disconnect, but the new guys cut the replacement run to size 🤦‍♂

  • @JoeCdaYT
    @JoeCdaYT Месяц назад +3

    I have seen something like that. Pull disconnect on the side of a federal building and the fire that had ensued inside the box had melted the insulation back to the wall. Our company sub-contracts stuff like that out. Lots of pictures and estimation of about 200 Ft of 10=2 wire to main panel. There was going to be some drywall work involved if it was done as a new pull since the old run was Romex. I know the feeling of On-call, have it this weekend and Saturday night got called out for a noise complaint at a high-end condo where big money is spent for people to be able to take over 4 Units to make one unit on the lake. 4 Floors and all. Noise was heard in multiple units in a unit stack. Boss said to find the culprit. Well I did with on call time and will let him deal with the logistics of billing that but found out there is a central booster fan for all the vents to go into and the fan itself had bearings going out. 3 Hours total in this whole mess.

  • @dashcamandy2242
    @dashcamandy2242 Месяц назад +16

    Yawning isn't always a sign of fatigue. According to a brief Google, partially to confirm what I learned in grade-school science, but in the process I discovered several other benefits:
    * yawning causes your body to release a wetting agent into the alveoli (air sacs) in our lungs, keeping them "open" and ready to work
    * yawning opens up the jaw muscles, increasing blood flow to the brain
    * yawning causes you to breathe deeply, flushing any remaining "stagnant air" from your lungs, and offers some small cooling effect to the brain as well
    The More You Know 🌈🌟

  • @Granth_Man
    @Granth_Man Месяц назад

    I drink cold coffee and watch ur vids every day

  • @PhillipFrischman-vo8gm
    @PhillipFrischman-vo8gm Месяц назад

    You are probably absolutely right good job

  • @opnoah2085
    @opnoah2085 Месяц назад

    7:15 is me every time I’ve opened up a Trane condenser panel this season and seen 10 wasps fly out at once. Gave quite a few home owners a good chuckle

    • @jollygreen4639
      @jollygreen4639 Месяц назад

      I always had a can of hornet spray in my tool bag. Always checked the panels and inside for nests, etc the best I could. One day, somewhere I disturbed them and they came after me. I got four stings on my upper forehead and three in the outside corner of my left eye. In five minutes, I started to feel funny, went to security, they called an ambulance because I may have started to go into shock. So the ER dr told next time could be worse so I now have to carry an EpiPen with me just in case. This happened when I was in my early 50’s.

  • @89dhvac
    @89dhvac Месяц назад +15

    Why in goodness name did they pull new wire from the j box to the unit and re splice the wire?!?!? Why would you not take that opportunity to eliminate the j box and splice or even leave the j box but at least eliminate the splice…

  • @ShukenFlash
    @ShukenFlash Месяц назад +6

    The pull likely caused some of the damage, particularly since the wire was old and the insulation would have likely become brittle over time. But it's also plenty likely that there was water in the old conduit and that contributed too. That wire was definitely jacked up when it came out. The insulation shouldn't have gotten messed up on the new wire, partly just because it's new insulation and not old and brittle. They also generally use a lubricant to help the wire slide through the conduit, at least if it's tight.

  • @JAMESR.-xo3tt
    @JAMESR.-xo3tt Месяц назад

    You gotta love the yellow jackets!

  • @johnbreland4099
    @johnbreland4099 Месяц назад +2

    Perfect time to check voltage at the fused disconnect, even know it’s turned off. Also while working on that circuit pull the fuses out, just in case someone doesn’t walk by and flip breakers cause their oven or outlets not working 👍

  • @k11ll33rr
    @k11ll33rr Месяц назад +6

    Best you made was telling the customer to go get an Electrician. I wouldn´t even have cogitated stripping something like that 4in clean, you´ve shown how the wires were cooked throughout the whole lenght, condensation could come back bite you in some time and might even short it worse inside the roof where a fire could take place.

  • @helmsajr
    @helmsajr Месяц назад +1

    Great job Chris has always.

  • @melvinlazear8068
    @melvinlazear8068 Месяц назад +1

    good job Chris something definitely shorted to ground keep up the good work

  • @dalemarr70
    @dalemarr70 Месяц назад +2

    Hey, 4th of July on the roof ! Maybe a bad Polaris installation? Those things were jamed in there from the beginning. Water would have drained on down.

  • @rogerghiardi7723
    @rogerghiardi7723 Месяц назад +4

    Call the electrician, holy crap

  • @tracysellman1562
    @tracysellman1562 Месяц назад +1

    Dude I was laughing so hard when I saw the trash the electricians left, I always take a pic of shit like that, it not only irks me but sets my OCD into Bull shit mode. lol and when you said "No comment," I said that's not what you are thinking. PS: I always clean up what I can, but get so tired of cleaning up other people's trash and just think it is BS! lol

  • @quietone610
    @quietone610 Месяц назад +1

    Some pedantic nitpick: It's a SwitchBOARD if it's 600V or lower (line to line or line to ground). It's SwitchGEAR above that (i.e., 3kV, 12kV, and above). The Transformer that bridges the two is technically part of both.

  • @madtown_refer_tech9477
    @madtown_refer_tech9477 Месяц назад +2

    I have seen and had a lot of Polaris connectors fail. I personally dont use them anymore. Just went back to using copper split bolts.

  • @zekenzy6486
    @zekenzy6486 Месяц назад +1

    Great video. Thank you for sharing

  • @rockercover
    @rockercover Месяц назад +1

    Glad no one was near that electrical meet-point box on the roof when the wires burned.

  • @skorpion1298
    @skorpion1298 Месяц назад +1

    Hmm who does not love Crunchy Cables! Nice :D

  • @kens.3729
    @kens.3729 Месяц назад +5

    Contractor Clean-up is a Make or Break thing. If they Leave a Mess on the Ground, I can only Imagine how rest of the job was Done. Clean Up your Mess or Else. 🤪👎

  • @andrewrixon2347
    @andrewrixon2347 Месяц назад +7

    I can’t believe that American sparkys can get away with 4 wires all the same colour to termination points ! R-Y-B & Green…not difficult….

    • @AZ-zn3ru
      @AZ-zn3ru Месяц назад

      I mean it’s qualified professionals working on these machines…..

  • @TheChipmunk2008
    @TheChipmunk2008 Месяц назад +3

    My guess would be a loose connection melted the connector or softened the insulation on A phase, which then shorted to the grounded lid for a while, heating up the fuse along with blowing bits of the faceplate all over the place, then it blew, and the unit shut down because of losing a phase (I know that last bit you already told us). I'm amazed with all the heat and plasma flying around that the other 2 phases were still live.
    And as for those electricians leaving the panel door open and going for lunch, man I hope their public liability is good, can you imagine if a kid had wandered in?

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад

      I cant imagine what they where thinking

  • @joshua.sookoor2025
    @joshua.sookoor2025 Месяц назад +3

    Holy crap, inside that box was black like tar, plus its crispy like fries definety had an electric fire! Im surprised the whole box didnt melt! Is it plastic or metal? Nice job chris!

    • @letterslayer7814
      @letterslayer7814 Месяц назад +3

      the faceplate is metal so i would say the box is metal as well
      if not it would probably be very droopy

  • @Paul-IE-Repairs
    @Paul-IE-Repairs Месяц назад +2

    250.119 violation
    250.119 Identification of Equipment Grounding Conductors.
    Unless required elsewhere in this Code, equipment grounding conductors shall be permitted to be bare, covered, or insulated. Individually covered or insulated equipment grounding conductors shall have a continuous outer finish that is either green or green with one or more yellow stripes except as permitted in this section. Conductors with insulation or individual covering that is green, green with one or more yellow stripes, or otherwise identified as permitted by this section shall not be used for ungrounded or grounded circuit conductors.

  • @stillthakoolest
    @stillthakoolest Месяц назад +2

    Also, modern THHN has a nylon jacket on it that is not part of the insulation rating. It provides some gasoline resistance but is otherwise sacrificial for during the pull - and it can make the wire look "fucked up" but doesnt affect the insulation. They probably didnt use enough lubricant either time

  • @glennduxbury2568
    @glennduxbury2568 Месяц назад +1

    WOWIE !😮

  • @oscalerup1129
    @oscalerup1129 Месяц назад

    Crazy. Had a convince store that couldn’t find a key so I could get behind the building to work on a walk in cooler. Told them they better get a new lock. 😉

  • @websterleone
    @websterleone Месяц назад

    The electricians said the old wire was damaged from the pull, I hope they at least used cable lube for the new wire. I've used it before in a conduit run with one or two too many bends and it helped tremendously.

  • @jonleiend1381
    @jonleiend1381 Месяц назад

    Wow that is crazy.

  • @tinymanthebeast
    @tinymanthebeast Месяц назад +4

    is that unit on the Los angles power grid? the unit might need a
    . ICM Controls ICM450 3-Phase Monitor . the same thing might happen again because of the power grid dropping out or spiking. power grid voltage starts dropping down motor amps go up .

  • @patriknilsson2175
    @patriknilsson2175 Месяц назад +10

    As I have mentioned before, and will do it again. America electrics looks like stoneage stuff comparing to european standard. There's no way we are allowed to install metal cases for electric breakers or couplings. Everything is uv-resistance plastics today to minimize electric chocks if a wire gets damaged/loose and shortcuts to the casing.

    • @patriknilsson2175
      @patriknilsson2175 Месяц назад

      When it comes to control cabinets and fuse boxes for industrial use it's ok to use metal cabinets, but they are painted with some esd paint, and breakers still in plastic.

  • @zidane2k1
    @zidane2k1 Месяц назад +1

    When you showed the new box the electrician put in, I noticed the Cantex logo on the cover was upside-down, and now I’m wondering, did you see it and put it upright before you left?

  • @raytheexplorer5198
    @raytheexplorer5198 Месяц назад

    My ice merchandiser was not cooling. So I add R134-A. I keep adding Freon but suction pressure goes up and then come back on 0 psi pressure. I leave it on for one day. Inside the freezer ice bulid up on two side but not reaching 20 Fahrenheit temperature. Right now is doing 26 Fahrenheit it’s ON almost 24 hours.
    Thanks in advance

  • @DocNo27
    @DocNo27 Месяц назад

    Talk about angry pixies! 😳

  • @kennethlobo4420
    @kennethlobo4420 Месяц назад +1

    Nasty short circuit

  • @mnoxman
    @mnoxman 2 дня назад +1

    That wire was fried more than a tweaker.

  • @dbell41888
    @dbell41888 24 дня назад +1

    I'd remove jbox and do a temp connection if after hours or weekend till electrician showed up. Never had service electrician ever show up that quick. I'd also help him pull if he's cool.

  • @legionofanon
    @legionofanon Месяц назад +3

    Ive had a 3phase 20HP water pump melt through a wire nut (yeah a wire nut, not a marine grade lug block, smh) and short on the case, never blew a fuse or tripped anything

  • @NorthernS0utherer
    @NorthernS0utherer Месяц назад +1

    I hate to see the bill on an emergency service call like that where you have to rewire a whole thing.

  • @jo6520
    @jo6520 Месяц назад +2

    I see that a lot with electricians. We had our telephone pole get hit with lightning, and the power co came out to fix it and left the garbage in the woods behind my house.

    • @dan4age
      @dan4age Месяц назад +1

      Only thing they take is clean copper 😆

  • @XolaresTiberius
    @XolaresTiberius Месяц назад +1

    That box went nuclear!

  • @mustangdbest220
    @mustangdbest220 Месяц назад +1

    Love the videos and 4K 60 now idk if your phone supports HDR BUT IT WOULD BE AMAZING to have HDR

  • @MichaelATH
    @MichaelATH Месяц назад +6

    I think it’s an international thing with electricians not tidying up! Ask any trade in the UK who’s the messiest…….

    • @dan4age
      @dan4age Месяц назад

      Same with Australia

  • @dj970708
    @dj970708 Месяц назад

    In Germany we have to choose the Fuse based off the Cable we use, if we deliver 400VAC with a 5x cable, we HAVE TO take a Fuse with 3 coupled Fuses. So in the event of failure, or just for turning off, ALL Live wires have to get turned off!
    Based off these Arcs, i would just guess either the Fuse failed and didnt turn off (which is not possible in Germany Fuses, as they would internally fail and disconnect the circuit (all 3 Phases) or the Screwnuts were either lose or overtightened. When you screw them too much into the Wire it could help the wire to break and while it breaks/fails, it can happen that it will arc really badly, based on the load aswell, the more load, the greater the arcs

  • @adamkane3736
    @adamkane3736 Месяц назад +1

    Man... Glad you were able to get it going again, but as someone in the electrical industry... Those guys were hacks. Pulling red wires for everything, plastic junction box on a rooftop, leaving a mess behind. I'm not sure why they choose to put a splice back there again instead of just using that box as a pull box and keeping the conductors continuous all the way to the unit.

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад

      Yeah I was wondering the same thing

  • @joeformisano1299
    @joeformisano1299 Месяц назад +1

    Electrician crumbs!!!

  • @tyhuffman5447
    @tyhuffman5447 Месяц назад +3

    Safety question, why not shut the main breaker prior to opening the box? What could have been found that could have been fixed with the breaker on? Trash - "We are what we repeatedly do. Excellence, then, is not an act, but a habit"

  • @tuttocrafting
    @tuttocrafting Месяц назад +2

    Is there no code over there to differentiate the different phases wiring?
    Here pulling a red wire for ground with taped color yould be a big no no.

  • @ni_wink84
    @ni_wink84 Месяц назад +1

    Chris you’re like me, I’m like red for ground huh? Ok… my friend is an electrician he always says the wire doesn’t know what color it is, I always say yeah now I don’t either 😂

  • @NorthernS0utherer
    @NorthernS0utherer Месяц назад +1

    I thought it was just an East coast thing, but electricians are afraid of brooms.

  • @KaldekBoch
    @KaldekBoch Месяц назад +2

    "I do the recordings for my employees". Geez it's been at least two years and I haven't seen a paycheck! 😂
    In all seriousness, I know it's the ultimate defuse statement for someone who's just looking to get defensive or angry about being around a camera.

    • @Eledore
      @Eledore Месяц назад

      So i wasn't the only one wanting to do the paycheck joke of my second job..

  • @josephconway1968
    @josephconway1968 Месяц назад +1

    Electricians and Baseball players, both Prima Donna's!😁😎

  • @davidnull5590
    @davidnull5590 Месяц назад +2

    The hole blown in the electrical box was caused by a bad connection in the electric box; somebody made a poor connection, over time (cycles of the A/C turning off and back on) wore away at the already bad connection. I wonder how the roofers installed a TPO membrane around the electric penetration? A guess is the roofers made the install easier for themselves by disconnecting the wires when they put the new roof on.
    The roofers did a poor job reconnecting the wires (obviously) - they'll never admit this.
    Water isn't involved here, these are poor mechanical connections, those bad connections break with dramatic results.
    Electricians leaving garbage behind? It greatly irritates me; it seem to be an electrician's tradition

  • @Epiccatsandkittens
    @Epiccatsandkittens Месяц назад

    That junction box looks like it had a fire in it at one point. And when they pulled out the wire, I'm surprised it didn't cause an electrical fire. That could have easily resulted in a fire and caused extensive damage to the restaurant. So I'm sure the customer is grateful that didn't happen.

  • @jo6520
    @jo6520 Месяц назад +1

    They need a proper disconnect on the roof for each A/C just I m case of an emergency

  • @RayRay-nb7tn
    @RayRay-nb7tn Месяц назад

    I would say that one of the lugs must've came loose and heated up and blew the hole in the box. IMO. We'll al least the Sparky came out quickly to get that up n running. Could've,Should've, maybe checked amps on the Cans each? Don't know just saying to put on your exempt list. Great video Chris keep up the great work bud.

  • @tweake7175
    @tweake7175 Месяц назад +2

    why on earth do you guys have electrical entry points on top of the box where water can get in ?

  • @redneckcoder
    @redneckcoder Месяц назад

    You missed a perfect "When theres your problem lady" chance.

  • @huababua8203
    @huababua8203 Месяц назад +4

    I have nothing to do with your field of activities but I hope I come across a non-functioning AC at one time in my life and do what I learned :p :D

  • @JamesBarnes-xd9bj
    @JamesBarnes-xd9bj Месяц назад +1

    Hope the electricians aren’t the same as before!

  • @deineroehre
    @deineroehre Месяц назад +1

    It seems like colour Coding is optional in the US and some shrinktube will do the trick?

  • @coreyr8870
    @coreyr8870 Месяц назад +2

    Why would they use connectors again. Did not want to pull that extra 6ft of wire.

    • @HVACRVIDEOS
      @HVACRVIDEOS  Месяц назад +1

      I was kinda surprised at that

  • @joeyf504327
    @joeyf504327 Месяц назад +2

    electricians are allergic to brooms! Also, why keep that stupid box? Makes no sense what they did.

  • @UsTrainsAndSirens
    @UsTrainsAndSirens Месяц назад +1

    At 9:09 on the tablet, how do you get those readings or what do you use to connect to the line sets to read with a tablet or computer?

  • @ivoryjohnson4662
    @ivoryjohnson4662 Месяц назад +1

    Staying in your lane reduces liability. What if the underground run is jacked and it starts a fire

  • @krazy1z
    @krazy1z Месяц назад

    Chris you should make shirts thst say "1,2,3 Please don't blow up" 😁

  • @_ohmz_electric
    @_ohmz_electric Месяц назад +1

    That electricians a hack

  • @stillthakoolest
    @stillthakoolest Месяц назад +4

    Lazy electricians right there. Who doesnt have a spool of 10 green?

  • @sk31370n
    @sk31370n 6 дней назад +1

    when can i expect my paycheck?