  • @nicholaskaputo6059
    @nicholaskaputo6059 10 месяцев назад

    When finding the load due to sheets and the live load it is not necessary to multiply by one (×1m) because (0.5kN/m² x 1.8m) will give =>900N/m.......multiplying by one (×1m) wasn't necessary......please check through your work again

  • @ramgirishanmukh4643
    @ramgirishanmukh4643 2 года назад

    Thank you...

  • @vasu4628
    @vasu4628 3 месяца назад

    From where u taken the value of zyy

  • @kiranchaudhari7580
    @kiranchaudhari7580 2 года назад +1

    you have to calculate Zpy along y axis by using the concept sumation of AY .
    Zpy = Iyy * shape factor is that correct ?????

    • @symphony2003
      @symphony2003 8 месяцев назад

      yeah, i was also thinking the same. and it is satisfactorily enough as it doesnot fails during check for combined bending. so ig it is safe to use safe factor. why to do more while we can short out easily?

  • @s_hubh78
    @s_hubh78 4 года назад +1

    Also is it necessary to calculate plastic modulus along the y axis

  • @akashdarwatkar9068
    @akashdarwatkar9068 4 года назад

    Sir,
    How find following component angel / channel selection
    1) main tie = ?
    2)principal rafter = ?
    3)sag tie = ?

    • @Civillearningonline
      @Civillearningonline  4 года назад

      Hello dear,
      Your question will be clear form the diagram of a roof truss.
      And for that i need to add a video about it or u can consult some book like s.s. bhabikatti.Choice is yours if you want me add a video then let me Know by replying this comment.
      And i would like to thank for your comment.

    • @Civillearningonline
      @Civillearningonline  4 года назад

      Here is your answers
      ruclips.net/video/OHFqry8-J9w/видео.html
      And i m extremely sorry for being late

  • @s_hubh78
    @s_hubh78 4 года назад

    Why didn't you calculate shear capacity

    • @Civillearningonline
      @Civillearningonline  4 года назад

      This video was made from the exam point of view so that all thr important steps can be completed and students can get full marks.

    • @s_hubh78
      @s_hubh78 4 года назад

      Thank you sir
      Yours way is the easiest I have seen

    • @s_hubh78
      @s_hubh78 4 года назад +1

      There is another question sir
      If only dead load is given
      Do we need to calculate the factored load?

    • @Civillearningonline
      @Civillearningonline  4 года назад +1

      Yes if we are provided with dead load only then we have to take live load load 100N/m and wind load will be given in the question. And after taking all those loads we need to multiply those loads by factor of safety as shown in the following video. And after doing so we proceed our solution.
      Hope i met your confusion.
      Have a nice day.

    • @s_hubh78
      @s_hubh78 4 года назад

      Thnks a lot sir

  • @ganeshyadavflashgaming3286
    @ganeshyadavflashgaming3286 3 года назад

    Sir in calculation of required zpz u have not used ymo(1.1) after myy/fy

    • @Civillearningonline
      @Civillearningonline  3 года назад +1

      If it's present in formula then it needs to be used otherwise not.

    • @ganeshyadavflashgaming3286
      @ganeshyadavflashgaming3286 3 года назад

      @@Civillearningonline in previous problem u have used that's why I asked sir

    • @Civillearningonline
      @Civillearningonline  3 года назад

      Yes, it id missed .
      We need to multiply it with ymo( 1.1).
      Thank you.

  • @piyushvaishnav18
    @piyushvaishnav18 Год назад

    SIR CALCULATION OD LOAD ME 1.8 KYA HAI PLEASE REPLY

    • @symphony2003
      @symphony2003 8 месяцев назад +1

      hi, 1.8 is there because of spacing of purlin is 1.8Meters. it should be multiplied to gain the parameter in KN/m.

  • @-Thimmaraju
    @-Thimmaraju 4 года назад +1

    Nice

  • @keerthanav410
    @keerthanav410 2 года назад

    Sir where did you find the shape factor

    • @symphony2003
      @symphony2003 8 месяцев назад

      is 800:2007 annex H , plastic properties of beams

  • @abarajitharamachandran1866
    @abarajitharamachandran1866 4 года назад

    Sir what if pitch is given as 1/4 and angle is not given

    • @Civillearningonline
      @Civillearningonline  4 года назад +1

      Hello dear,
      When angle is not given then use the formula
      Tanx=(height of truss/half of span of truss)
      Or,
      U can watch my video on the design of channel section where i have mentioned this formula in the description go and check it out.
      Thanks for ur comment.

    • @abarajitharamachandran1866
      @abarajitharamachandran1866 4 года назад

      @@Civillearningonlinethank u so much sir....

    • @abarajitharamachandran1866
      @abarajitharamachandran1866 4 года назад

      @@Civillearningonline sir but in this sum they didnt given the height of truss too... They only gvn the spacing , span, pitch as 1/4

    • @Civillearningonline
      @Civillearningonline  4 года назад +1

      We have a formula i.e.
      Pitch(p)=height(h)/span(L)
      Or,
      Take assumption as x less than or equal to 60.
      For making the design economical value of x is taken between (20 to 30) degree.

    • @abarajitharamachandran1866
      @abarajitharamachandran1866 4 года назад

      @@Civillearningonline tysm sir.... U r really best.... Thnks fr ur response...

  • @yeshwanthgurrapu2421
    @yeshwanthgurrapu2421 4 года назад

    y u used WL SQUARE 2/8

    • @Civillearningonline
      @Civillearningonline  4 года назад

      That's the formula to find moment in case of UDL.

    • @Civillearningonline
      @Civillearningonline  4 года назад

      Always keep in mind; Whenever live load comes either with dead load or singly we consider it as UDL.

  • @FinanceTalkWithDileep
    @FinanceTalkWithDileep 4 года назад +1

    I have supply 😍😍🤩🤩

  • @manishkumar-pv5rl
    @manishkumar-pv5rl 3 года назад +1

    How to find Zyy

    • @Civillearningonline
      @Civillearningonline  3 года назад

      In order to calculate Zyy.
      First you need to find MOI about y axis and then divide it by half of width.

    • @manishkumar-pv5rl
      @manishkumar-pv5rl 3 года назад

      In this question you donot find moi then how to find zyy

    • @venkyrce
      @venkyrce 3 года назад

      Simple- zpy = a×y,where y is centric distance to yaxis

    • @venkyrce
      @venkyrce 3 года назад

      a = area of member

    • @AJAYKUMAR-ul8im
      @AJAYKUMAR-ul8im 6 месяцев назад

      In a steel table rolled steel channel the zyy=zey

  • @shornashomebaking5456
    @shornashomebaking5456 2 года назад +1

    Not audible

  • @vikashmahato272
    @vikashmahato272 4 года назад

    bhai hindi me hi smjhao english jabardsti kyo bol rhe ho hindi sb psnd krta h

  • @ashoks8084
    @ashoks8084 4 года назад

    Sir if any check is not satisfied do we need to redo then What section want to choose

    • @Civillearningonline
      @Civillearningonline  4 года назад

      Hello dear,
      U need to redesign the section only if your section fails at the beginning of the solution of the Numerical from the exam point of view. Otherwise you can mention that "the section fails and we need to redesign taking another section" if it fails at end..
      And as far check is considered " one can mention that the given section fail here".

    • @Civillearningonline
      @Civillearningonline  4 года назад

      DCS and DSS are design subjects and one just needs to know the proper steps to design a section for exam.
      And one becomes best in selecting the proper sections through practice.
      The more you practice the more u learn.
      Now a days all sections are designed through different softwares like ETAAB, STADD PRO.
      Where there is need to do so much lengthy calculations nor to apply checks. One just need to enter the data and the section is designed by the software.
      So don't worry just prepare well for your exam.
      Best of luck.

    • @ashoks8084
      @ashoks8084 4 года назад

      Thankyou sir

  • @pkentertainments20
    @pkentertainments20 3 года назад +1

    Please improve your voice

  • @ahmedilyas3014
    @ahmedilyas3014 4 года назад

    which code is being followed??

  • @alkasingh5098
    @alkasingh5098 3 года назад +1

    Op