  • Three-phase power is a three-wire ac power circuit with each phase ac signal 120 electrical degrees apart. ... three-phase is that a three-phase power supply better accommodates higher loads. Single-phase power supplies are most commonly used when typical loads are lighting or heating, rather than large electric motors.
    #3PHASE#LOAD#BALANCE#
    thanks for watching please like and subscribe:
    Copyright Disclaimer under section 1
    07 of the Copyright Act of 1976 allowance is made for "fair use " for purpose such as criticism comment, news reporting ,teaching, education and research.
    Fair use is a use permitted by copyright statue that might otherwise be infringing
    this is my youtube channel link:
    👇
    ruclips.net/user/ch...
    PLEASE FOLLOW MY FACEBOOK PAGE :
    👇
    / 183081473272155

Комментарии • 89

  • @albertopiniano8524
    @albertopiniano8524 5 месяцев назад

    Thanks for these vital info. God bless po

  • @rolandodelapaz3970
    @rolandodelapaz3970 3 года назад +2

    Nice tutorial of basic electrical system salamat sa sharing kabayan . God po

  • @armandoabonitalla9373
    @armandoabonitalla9373 Год назад

    nice tuturials idol...malaking tulong to sa amin👍👍👍

  • @edspayas550
    @edspayas550 Год назад

    Galing mo sir mag paliwanag....salamt sir

  • @adonisalfonso8328
    @adonisalfonso8328 2 года назад

    Mabuhay ka SIR, Salamat po.

  • @rsrtechnicrocha5407
    @rsrtechnicrocha5407 2 года назад

    Salamat idol nadagdagan ang knowledge ko

  • @hanipbuhay
    @hanipbuhay Год назад

    New friend here full support ka technician

  • @vonakidloft7603
    @vonakidloft7603 Год назад

    Galing salamat sa kaalaman

  • @brenoncasio4451
    @brenoncasio4451 2 года назад

    SALAMAT PAPS MARAMI AKO NATUTUNAN

  • @renzofficial2435
    @renzofficial2435 3 года назад

    Good tutorial master, my dagdag kaalam naman

  • @jezrellegatila76
    @jezrellegatila76 2 года назад

    Salamat po malaking bagay sa 1st timer

  • @bonifaciomapajr.4411
    @bonifaciomapajr.4411 Год назад

    Salamat po sa Video sir

  • @markbuccat9910
    @markbuccat9910 Год назад

    Slmt malinis k mg turo

  • @ricbingchanel31
    @ricbingchanel31 2 года назад

    Salamat master

  • @huanfriend8857
    @huanfriend8857 3 года назад

    Nice video, watching iloilo tech💖

  • @jhunebarttv9145
    @jhunebarttv9145 Год назад

    Nice video lods new Subscriber 🤟
    Laking rulonh ito

  • @kadiskartetv6578
    @kadiskartetv6578 3 года назад

    Ayus lodi..

  • @genaromagpali6591
    @genaromagpali6591 Год назад

    Thanks Sir

  • @davefuntilon5591
    @davefuntilon5591 7 месяцев назад

    Okay na lng boss Kung y ang transformer mo, pero Kung delta merong highleg.

  • @rauljacla8015
    @rauljacla8015 2 года назад

    Shout out Naman po sir madami aq natutunan say Foreman po aq sa cavite name kupo Raul jacla God Bless po.

  • @eigoobschannel1086
    @eigoobschannel1086 Год назад

    Ayus

  • @bryanmarano7516
    @bryanmarano7516 5 месяцев назад

    Ty

  • @ejaybeltran5242
    @ejaybeltran5242 7 дней назад

    Boss ung computation mo dun sa 380 nd maxadong malinaw kung saan mo nakuha 1.something n cnasabi mo. Paki explain ng mabuti. At ano ang difference ng bawat line para masabing balance n xa.

  • @kuruzakichigo96
    @kuruzakichigo96 2 года назад

    Very informative video. Maraming salamat. Ask ko Lang po Kung possible ba at pwede kumuha Ng 220 volts SA 3phase line to line connection at paano?

  • @shadowken1214
    @shadowken1214 2 года назад +2

    Matanong lang sir. Sa pinasokan kong trbahao convenience store. Bakit naging ganito ang reading sa mga Hot wire to Ground?
    L1 to Ground = 220v
    L2 to Ground = 110v
    L3 to Ground = 110v
    Pero yung L2 at L3 ay hindi naman shorted sa Ground dahil kung shorted dapat nagkakaputukan na. Sana masagot mo sir salamat

    • @jub.tv123
      @jub.tv123  2 года назад

      Sang bansa sir san ba yan?..at ilanh volts ba ang line to line sir?..

  • @josenisay4886
    @josenisay4886 9 месяцев назад

    Galing, 3phase ba na panel box kailangan ko sa bahay ko ?

  • @JojoCruzSolano
    @JojoCruzSolano 3 месяца назад

    sir pag sinabi ba 3 phase tatlo na liya galing sa poste i kakabit ao yun kasi mag line 1 line 2 line3 san galing isang linya sa poste din ba

  • @alfieabejar8818
    @alfieabejar8818 8 месяцев назад

    Nice content sir.more power...sir may tanong lang ako.may equipment kami na 3phase 220V lagi nasusunog ung connector ng 1 namen load(by the way pre-heater po ito.na may working temperature na 310⁰C po).nung magcheck ako e ung breaker nya is 120v lang.ayun kaya sanhi nun sir.salamat

    • @jub.tv123
      @jub.tv123  8 месяцев назад

      Yes po kasi pang 120v lang sya kailangan naka 220v Yong breaker nio po...palitan nio nalng sir,....

  • @joeycrisostomo5910
    @joeycrisostomo5910 10 месяцев назад

    paano kung single phase motor mayroon rotation yun kung basta mo lng ikbit sa line to neutral bka pabliktad yun ikot nyan

  • @user-fy7sn1hd5o
    @user-fy7sn1hd5o 9 месяцев назад

    Saan ka po ba kumuha ng Neutral Line master Kasi Yung Isa ay Live line?

  • @apollorearte290
    @apollorearte290 8 месяцев назад

    Papano mo sir nakuha ang 225AT ng main breaker?

  • @basicelectricalwiring503
    @basicelectricalwiring503 2 года назад

    Sir,ilang amperes dapat na masabi natin na balance po.?ilan po ang agwat nila kapag hndi balance?

  • @janicelamadora611
    @janicelamadora611 Год назад

    Sir pno Po Yung sa aircon n trepahase pno mag balance nun sir?

  • @arindar4310
    @arindar4310 Год назад

    saan ka nagwowork idol?

  • @mannydoma1333
    @mannydoma1333 2 года назад

    Boss ano pong switch? Ung breaker po ba yun

  • @Link-tt6mw
    @Link-tt6mw 2 года назад +1

    Sir malaking tulong po mga videos niyo. More power. Tanong ko lang po sir. Pag ganyan po ba na nilagay sa single phase line to neutral mahahati po yung 225 A na capacity ng Breaker kada Line?
    Example po :
    Line 1 to Neutral - 225
    Line 2 to Neutral - 225
    Line 3 to Neutral - 225
    .
    .
    Tapos kapag ginawang 3 Phase naman magagamit yung 225A na breaker ng Buo?

    • @jub.tv123
      @jub.tv123  2 года назад +1

      Hindi po sir dapat sa 225 amperes 80 percent lang ang ma consume mo..sa lahat ng linya mo pag naka line 1 line 2 line 3 at line to neutral mo

    • @Link-tt6mw
      @Link-tt6mw 2 года назад

      @@jub.tv123 Sorry po sir magulo po yung tanong ko hehe. Ganto na lang po Example po may 225A na 3 phase main Breaker. Tapos dinistribute na po siya kada Line to Neutral. Ganto po ba ang Rating niya kada line to neutral?
      Line 1 to Neutral - 225 x 0.8
      Line 2 to Neutral - 225 x 0.8
      Line 3 to Neutral - 225 x 0.8
      .
      .
      Or mahahati po siya sa tatlo na parang ganto?
      Line 1 to Neutral : (225÷3) x 0.8
      Line 2 to Neutral : (225÷3) x 0.8
      Line 3 to Neutral : (225÷3) x 0.8

    • @emman8954
      @emman8954 9 месяцев назад

      Pano po sir pag dalawa pong panel board?

  • @mikeart1686
    @mikeart1686 Год назад

    Saan ba kinuha yong square root 3 sir?

  • @basicelectricalwiring503
    @basicelectricalwiring503 2 года назад

    Sir,pag tumaas ang isang line ng kahit 10 or 20 ampers.possible na po ba na mag trip ang breaker

    • @jub.tv123
      @jub.tv123  2 года назад +1

      Pag umabot ng 20 amperes ang deperencya sir maari nag trip ang main breaker mo

    • @basicelectricalwiring503
      @basicelectricalwiring503 2 года назад

      @@jub.tv123 kahit siguro hindi overload sir,basta unbalance ang pag gamit ng power.maaari din po ba na mag trip sir?kasi hnd naman lahat o sagad ang pag gamit..

    • @basicelectricalwiring503
      @basicelectricalwiring503 2 года назад

      @@jub.tv123 lagi lang nag ttrip..

  • @whoesnextgaming6526
    @whoesnextgaming6526 3 года назад

    master halos parehas lng dba po ang ground at neautral..for example ktulad sa mga bhay

    • @jub.tv123
      @jub.tv123  3 года назад +2

      Sir mag kaiba po ang neutral sa ground..kasi ang neutral di maboo ang sytem mo ..na single phase pag line to neutral na 220 ang trabaho po ng ground kong may short ang line mo sa body ng panel or apliances e drain nang ground mo sa earth or e trip nya ang ckt. breaker mo pero pag e test mo ang volts ng neutral at ground ZERO PO ang volts nyan...

    • @AngelGarcia-pl9sv
      @AngelGarcia-pl9sv 3 года назад

      Saan po ba ang connection ng neutral salamat po

  • @pikz357
    @pikz357 2 года назад

    Sir d2 smen 3phase 4wire gamit L1, L2, L3 tas ground tanong lng sir ilan po ung voltage ng bawat line, e2 po b ung tinatawag na 380v

    • @jub.tv123
      @jub.tv123  2 года назад

      Sa 3 phase sir mayron 380 v 440 depende kong ano supply nio sir yon na sng mging voltahe non...

    • @pikz357
      @pikz357 2 года назад

      @@jub.tv123 sir ano po pg kakaiba ng 380v at 440v my pg kakaiba po ba sa design ng panel board

  • @Woowiieee0598
    @Woowiieee0598 2 года назад

    Pwde ba lagyan ng 2 pole yan?

  • @AmacaFidel-cm4yb
    @AmacaFidel-cm4yb 3 месяца назад

    Boss paano gumawa ng 3 phase 230v

    • @jub.tv123
      @jub.tv123  3 месяца назад

      bili po kau ng transformer na 3 phase 230 sir para mag karon ka ng 3 phase

  • @rpeonruzzel1294
    @rpeonruzzel1294 2 года назад

    Okay lang po ba na unbalanced ang current sa 3phase? Kasi po same scenario po tayo. ang akin lang po nagdagdag ako ng 3phase aircompressor

    • @jub.tv123
      @jub.tv123  2 года назад

      Hindi dapat unbalance...sir kasi mag trip po yon

  • @aldohomeres409
    @aldohomeres409 2 года назад

    Kung 3phase 4wires sir paano po ang orientation ng wiring sa branches?thanks po and God bless.

    • @jub.tv123
      @jub.tv123  2 года назад +1

      Pag 4 wires sir ang sinasabi mo mostly 440 volts or 380 volts po yan sir...ang main ..kaya dapat 5 wire po yan kasama ang ground...

  • @aldohomeres409
    @aldohomeres409 2 года назад

    Paano po Kung line po walang neutral 4 wires ground Ang Isa ganun pa rin ba orientation Ng wiring?

    • @pikz357
      @pikz357 2 года назад

      ganun din po tanong ko d2 kc smen ganun ginagamit 3phase 4wire L1, L2, L3 at ground ang isa, pg ganyan sir ilan po ang voltage ng bawat line, tas anong type ng transformer connection yan tnx po sa sagot

  • @basicelectricalwiring503
    @basicelectricalwiring503 2 года назад

    Sir,panu po mag check pag dalawang wire na malaki hnd kasya sa clamp,ok lang po ba isang wire lang e clamp ko,parehas lang po c ang reading ng amps.Salamat po?

  • @JimuelFallaria
    @JimuelFallaria 5 месяцев назад

    boss ung neutral po saan po kukuha ng supply

    • @jub.tv123
      @jub.tv123  5 месяцев назад

      Sa neutral busbar po don mo rin e connect kong mag line to neutral kna

  • @jvlmotovlog4034
    @jvlmotovlog4034 Год назад

    Sir taga san po kayo

  • @loydfernandez5490
    @loydfernandez5490 3 года назад

    SIR PAG 3 PHASE BA , yung talong wire e puru live ?

    • @jub.tv123
      @jub.tv123  3 года назад

      Opo sir puro live po yan

    • @loydfernandez5490
      @loydfernandez5490 3 года назад

      @@jub.tv123 thank po sir, dko pa kse kabisado msyado ang three phase , sa single lang po

  • @sipaglangtv6716
    @sipaglangtv6716 2 года назад

    Boss Jub may tanong ako.. May main breaker ako na 150 amp. 3 phase 380 volts Paano po ba basa nito kada Line ba 150 amp.halimbawa po 150 line1.. Line2 150 line 3 150 amp. Ganun ba basa o 150 amp. Buong Breaker na.. May 150A noong e clamp ko siya ang line1 38A ang line2 48A... Line3 34 A.. Nasunog kasi ang wire ng line 2 o naiit siya ano Kaya problema.. Salamat

    • @jub.tv123
      @jub.tv123  2 года назад +1

      Ang laki...pa ng allowance ng breaker mo sir.. ang line 2 mo bawasan mo ng load kasi medyo malaki po sir...at higpitan mo terminal sir kaya nasunog..po yan...

    • @sipaglangtv6716
      @sipaglangtv6716 2 года назад

      @@jub.tv123.. Salamat boss

    • @sipaglangtv6716
      @sipaglangtv6716 2 года назад

      @@jub.tv123 ..boss ganito Ang ginawa ko tinotal ko lahat Ang lumabas kada line ..38+48+34=120 Amp. yung breaker ay 150 A diba pasok na siya sa 80% Tama ba Ako

    • @jub.tv123
      @jub.tv123  2 года назад +1

      Tama po yan kahit mag 90 % pa yan amg load mo walang problema...

    • @sipaglangtv6716
      @sipaglangtv6716 2 года назад

      @@jub.tv123 ok boss sa salamat uli👍

  • @AngelGarcia-pl9sv
    @AngelGarcia-pl9sv 3 года назад

    Saan po galing ang neutral? Saan magkokonek?

    • @jub.tv123
      @jub.tv123  3 года назад

      Ang neutral po galing sa secondary winding ng transformer pag na 3 phase Y connection na sya..

    • @pikz357
      @pikz357 2 года назад

      ah it means sir 4wire lng xa L1 POWER, L2 NEUTRAL, L3 POWER, TAS ground ganun po ba...

  • @ELIGUE13
    @ELIGUE13 2 года назад

    Paano po ang sa line to line na 220v connection sir?

    • @jub.tv123
      @jub.tv123  2 года назад

      Pag single phase na line to line connection sir kahit sang linya lng ang ilagay nio sa switch...

  • @Hxa231jh
    @Hxa231jh 3 года назад

    Boss paano kung ang isang linya hindi balance ang voltage .eg L1 to N 230 pero ang L3 to N 280 anong dapat gawin nyan boss

    • @jub.tv123
      @jub.tv123  3 года назад +1

      ibig sabihin sir nag voltage drop kana ... kong di pareho ang boltahe mo ang gawin mo sir bawas ka Ng load... or palitan mo ang cable mo..

  • @judedeguinio6959
    @judedeguinio6959 3 года назад

    Boss san po kukuha ng neutral?

    • @jub.tv123
      @jub.tv123  3 года назад

      Don ka mag top sa neutral busbar sir

  • @rauljacla8015
    @rauljacla8015 2 года назад

    Shout out Naman po sir madami aq natutunan say Foreman po aq sa cavite name kupo Raul jacla God Bless po.

    • @jub.tv123
      @jub.tv123  2 года назад

      Cge po sir n upload po