Sir bomb calorie system me ek hi sample ki har baar alag alag riding aati hai, jaise benzoic acid kabhi 2.5aati hai to abhi 2.45, 2.4 ,2.47. 2.55tak aa jati hai
Apna concept clear rakhiye...or calculation koee wrong nahi hai..procedure me differenc ho sakta hai ..ADB or DB. Maine V.M. direct calculation kiya hai IM include hai .u can calculate as your Requirement of lab. SOP.
Very good video sirG
Thank you sir 👍 👌👍
Sir LAMC coke me agar moisture hai to use kaise dry karke test karna chahiye?
Sir iron ore aur sponge iron ka bhi silica same process hai kiya
Sir bomb calorie system me ek hi sample ki har baar alag alag riding aati hai, jaise benzoic acid kabhi 2.5aati hai to abhi 2.45, 2.4 ,2.47. 2.55tak aa jati hai
Aise me samajh ni pata ki kya Karu Aisa kyo hoya hai
Sir, i think there is something wrong in calculation. Because you ignore moisture which has contribution on VM and fixed carbon calculation.
Please Sir How to determine the Phosphorous in Lam Coke
Liquid silicate mein na2o kaise check kare
Thank you very much sir.
Sir please upload sulphur testing procedure in coke and coal.
Video uploaded
Sir, Coal sampling and moisture test ke bareme vedios banaye.
Sir muffle furnace ka temperature kitna hona chahiye
900
Sir Ramming Mass test ka video banaiye plzzz...
Sir coal me ash 47%or FC 31% to coal ki GCV kya hogi
Kya caol sample me FC %high hone se GCV me fark padta hai
Sir lab ka kou book milla ga
Sir char dolochar Ka JCB testing Ka video बनाइए ना सर plz
Sir coal ka phos ka procedure kya hai plz make video
Sir 3rd wt of vm test me lid ko aap hataya nahin eksath wt kar liye hain
1st weight v with lid me hi hai u watch video carefully
Sir ASH Ko kitne time tàk rakhna hay
2 hour
M.f. ka temperature kitna the sir
900
Thank you so much sir
Thanks sir
Moisture check ka video daliya plz
Thinku sir
Sir coal me nitrogen kse kar te
Ultimate analysis
Ash vm calculated ka video baniye sir
Caking index of testing process
Sir coil ka carbon ka video upload kijiye
Sir all testing chat book please in photo
सर इसका ग्रेट कितना कितना होता है
V. M and ash and f. C kya hai
हमें हार्डकोक कोयले काजी सी वी यम पता करना है
Sir contact number daily AAP kaha se ho
Ash ka calculation wrong i.e -result nenhi.
26.1276-25.9700/.9493. %=16.60
Sir wrong he ye sab....apne galat proximate calculation kiya he
Apna concept clear rakhiye...or calculation koee wrong nahi hai..procedure me differenc ho sakta hai ..ADB or DB. Maine V.M. direct calculation kiya hai IM include hai .u can calculate as your Requirement of lab. SOP.
Ash -me kiyo aa raha h
Coal sulfer vedio hona sir
Video uploaded
Sir
Apna contact no dijiye
VM galat bata rahe ho
Clt mistake
26.1276-25.9700/.9493=1.22
Sir apka number chahiye