    @serhiiantonin7634 6 месяцев назад

    8510B Vector Network Analyzer without S-Parameter Test Set can't measure any paramiters. Thet is rigth?

    • @jjoonathan7178
      @jjoonathan7178  6 месяцев назад

      Right, you need all 4 boxes but you can mix and match to meet your requirements. The screen and IF (box below the screen) stay roughly the same but you can choose 8340/8350/8360 as your source and 8514/8515/8516/8517 as your test set. Both the source and test set need to support the frequency you want to measure. If they don't match exactly that's ok, they just operate on frequencies they both support. There are lots of options in this family.