Sir ,, humare makan 100 gaj ka h or humne column nhi lagaye the , kya deewar ko kaat kar column lag sakte h jise apne is video me dikhaye ...or sir please yeh bhi bataiye ki 100 gaj ke ghar me 9 column lagwane par kitna khrach aata h please sir jarur batana .....apka channel bahut acha h
Sir ji...Mera 15 × 30 aria me garder fharsi ka grund flour bana hua he jisme ek room , kitchen and let bath bane hue he . 8 inch ki wall he . Hum ground floor ko toch kiye bina first floor bana sakte he kya ? 2 room with RCC chat . Please suggest kijiye 🙏🙏
Mera Ghar 2018 me bana,jisme column aur pillers hai,nichey beam h but upar beam ni pada h... Bahar ki deewar 9inch ki hai, but Andar ki deeware 4 inch hi hai... Ab jab mujhe in chijo ka knowledge hua toh man bahut dukhi rahta hai,ye sab soch kar please mujhe kuch upay bataye ki mere ghar me majbuti aa sake
hello sir kia yeh possible nahi k sunken area main khanger bhrny ki bjaye hum isi hatch beam per walls utha lain aor jo slab k top ka level hy usi ko floor level man kr us per pcc kr k stone etc laga dain ??? dead load km krny k liye ???
भाई साहब concept आपका बोहत अच्छा था बस दो बातें कहना चाहूंगा , एक तो 5:28 पर देखिएगा जो beam है आपका वो column से out है जो की गलत है , beam एकदम center में होना चाहिए और दूसरी बात आप इसमें अगर rcc ceiling ( 12 mm 6" x 6" रिंग , single layer) देते तो ज्यादा अच्छा होता , छत का सारा लोड उस पर आ जाता |
aap ne beam ka size bataya. aur columns ka size kia hai kaun sa rod laga hai aur kitne distance me columns diya gaya hai maximum distance kitna hona chahiye
Sir aap ka video bahut acha hai ye merey bahut sarey doubt clear kiye hai..... Magar meray site par thora alag type ka challenge hai.....i wish I can communicate you through call or any other means.
sir ek question h aapse ye aapne jo hatch beam ground floor ki slab se uper 6 inch uthai h...m beam uper nh lejana chahta toh beam ki width k equal slab ko todhkar fr jab slab ka reinforcement dikhne lge usi reinforcemnt par beam ki bars niche ki side tie krke beam ko niche hi cast kru aur dono side column se support krna chah raha hu ..ye thk rahega.?????????.i hope you got my question....ye m bas ek room ki width badhana chahta hu...islye krra hu baki deewar k uper deewar ayengi first floor m....i wnt your suggestion...i will wait fr it.. although from my side i have done all the calculations..i want to clear my doubt
Video bahut achchi thi Jab hum footing k liye suppose 4'×4' ka area excavate karenge tab existing walls ka Kya hoga jo upar hai,isme to hmne sirf column wale area me hi wall todi hai Pls explain
भाई साहब यदि ग्राउंड और फर्स्ट फ्लोर पर 9 और 14 इंच की दीवारें हो तो क्या हम छत पर हैच बीम को नीचे की दीवाल पर रेस्ट कर के कहीँ भी दीवाल उठा सकते है? ,
Hi Aman ,but you didn't gave plinth beam to new columns ,one more thing if the quality of old slab is not good then it no use to give hatch beam and all am I correct?
Kya technically yah slab lot sear karega? Kunki normally desi type ke house constitution work Mai people desi civil work karte hai, Es type ke jugad working ko nhi kiya jaye , Kunki yah dekhna hoga ki lend kis zone mai aata hai, or soil report Kya hai.
Sir nice information .....mere Ghar me vertical beam hai par horizontal beam nahi Dale hai Abi to ground floor hai lekin upari manzil banani ho to Kase beam provide Kare
Hello ur amazing. Mje apne ghar ke piche baramde me bathroom banwane hai. Ek ke upar ek. Or wo piche wale kamro se attach honge. Uska kya procedure hoga...
Sir me video apka dekhta hun krpyaye batay ki niche se 2 feet upar beem wali d p c kaiae dale bena jyda dwae nuksanpahuchay aur beem kaise dale h am upar ka lenter tod kar 2 feet upar lenter dlna chah te he
Hello sir, 1 sir beam main lagne wala ring size kitna hoga. 2 Aur jeetne bhi deewar honge upar sab ke niche beam dena hain kya 3 2 mtr main jo beam lagega woh kya niche diye beam ke saman hoga kya.
Sir, Maine 6 mahine pehle chath ke upar 2 bedroom banaliye hain maestry se, lekin jaise ki aapne video me dikhaya ki hatch beam ke upar load de rahe hai, humne chath ke niche column hai to tikh column ke upri hisse pe load diya hua hai toh koi dikkat to nahi na sir?? Pls reply
sir hatch beam to plan ke hisab se dale he wall to wall sari wall bhi beam pr hi run kr rhi he colum nahi dale the aur hum ko bs yahi floor banana he koi dikkat to nahi he bs yahi pata krna cha rha ho
Sarvesh Patil nhi bro..floor finish ke leye aap ko very light material use krna Hai filling ke leye as.. Khangar (aac brick block waste) and then stone se finish KR lo ..Kyu ke old roof PE keval stone ka he mostly load hoga ..1st floor ke wall ka load column aur beam PE jyada hoga..thank for comment..
Very nice information.....but sir I have some doubt in my old house condition....sir Mera Ghar surkhi chuna ka hai....60 yr old....in good condition ...but some family problem ki wajah se....usme kuchh construction karana par raha.....surkhi ke upar ....mujhe RCC slab daalna hai....niche se column nikaal ke.....beam ke depth ka issue nahi samajh AA raha.....aap apna Instagram,Facebook ya Whatsapp number dijiye....aapse baat karunga.....if problem aayega banate time..... January me banana hai...after corona issue ....
Sir mera contractor slab pe hatch beam nhi daal rha, seedha first floor ka brick work start kr rha hai? kya woh thik kr rha hai.. slab almost 25 year purani hai ?
Sir mera ghar dealer ka bna hai aspas ki wall 4 inch ki hai aur bich ki ek wall 9 inch ki hai chatt pr koi bhi beam nahi hai upr bnana ho to wall ke upr hi bnana hoga kya ?
सर, मेरा ग्राउंड फ्लोर 2016 में बन गया था और उसमें कॉलम तो पड़े थे पर लेंटर से पहले लटक बीम नहीं पड़ी थी, ग्राउंड फ्लोर की खिड़कियों और दरवाजों के ऊपर फर्श से 8 फीट की ऊंचाई पर डोर बैंड पड़ा था पूरे मकान में, उसके बाद 3 फीट की चिनाई हुई और सीधे ईंट के ऊपर लेंटर पड़ा गया। ग्राउंड फ्लोर के कॉलम लेंटर से ऊपर 2 फीट निकले हैं, अब फर्स्ट फ्लोर की प्लानिंग चल रही है, ग्राउंड फ्लोर के कॉलम के साथ हम फर्स्ट फ्लोर के कॉलम खड़े कर रहे हैं, पर अभी उनमें कंक्रीट नहीं भरा है, तो मैं यह पूछना चाहता हूं कि हमें ग्राउंड फ्लोर के लेंटर के ऊपर हैच(फ्लैट) बीम देनी पड़ेगी या नहीं। और सर हमारी ज्यादातर दीवार तो नीचे वाली दीवार के ऊपर ही आ रही हैं पर 3 दीवार ऐसी है जो नीचे वाले कमरों के लेंटर के बीच में आ रही है तो क्या करें? Sir please reply fast......... urgent
Hello sir... nice information. I had a doubt.... sir, insted of using conventional coloumns and beams, can we use ISMB 250 or 150... depending on the load above..? Even for the hatch beams, can we use same ISMB?. Please clarify.
Kia is beam ka aik corner free reh sakta means cantilever??kion kay video may hatch beam free hay balcony ki side say mean kisi colum say connect nai hay..??
Sir..jab beam ko cast kiya jata h tab beam ka self wt. Old roof pr hi hota h.... Matlb beam poori tarf old roof pr hi rest kr rhi h... What concept y?... Ya to old roof ko beam se link Kiya Jaye tab to possible h ki beam old ka weight bear Kare..... I confused sir......
Sir mai bhi110 saal puraane makaan me chat par kmre. Banwa raha hu , thekedar ka kasa padta hai ki upR kamre ki base me jaala aur jumper .Plus beam ke bich me taaki upar ka l.oad nichr naa. A ye haalanki upar kamre ban a chuka hai abhi ties aur palastar baaki hai niche koi problem na ho kya karu
Sir ek question hai kya jo foundation se column uthta hai wo puri height tak jaye jaroori hai ya fir alag se kisi beam ke uper bhi column khada hota hai
Thanks sir,AAP ki vjh se mujhe apna ghar banane me kafi mmd mil rhi hai.... praveen Kumar Singh
AAP se sujhav hetu ,kis tarah bat ho sakati hai.
Aapne bahut achhi tarh she samjhaya hatch beam me bare me dhanyvad
Sir bhut achha lga video ,👍👍👍
Thanku so much sir mujhe apki video bot Jada smjh me ati h 🙏
Thank u sooo much sir u clear my doubts thank u sooo sooo much 🙏
Nice sir aapki baat hi nirale h
Bhut ache sir
Very important information...
Thank you very much... Big brother
... Radhe Radhe jai shree Krishna ji 🙏
thanks bro...radhe radhe...
Informative video 👍🏻
guys, kuch cheeze nazar andaz kare gayi hai??
Sir ,, humare makan 100 gaj ka h or humne column nhi lagaye the , kya deewar ko kaat kar column lag sakte h jise apne is video me dikhaye ...or sir please yeh bhi bataiye ki 100 gaj ke ghar me 9 column lagwane par kitna khrach aata h please sir jarur batana .....apka channel bahut acha h
Very nice video something different
Bahut badhiya ....
Very informative video. Thanks bhai jaan
Bina chath dale ghar banwa chuki hun aur ab usse ghar ko tode bina chath dalwana chahti hun kya asaa krwana possible hai please reply me
good engg.
good work. loads easly transfer to columns and and footing
bohot achha video...humara bohot idea huya...ek question tha...kya foundation me base flat beam neya contruct kiya?
Ha
suprb demonstrationsir! you let me clear all doubts in a moment ,only thing plz let me know how to relocate the bathrooms also in same floor
बहुत अच्छा वीडियो
Sir, how to provide cantilever slab for balcony in this type of house. Please give answer, I am watching your every video.
सॉइल फीलिंग के बाद रेत डालना है या इट के बाद रेत डालना अच्छा रहेगा
Sir ji...Mera 15 × 30 aria me garder fharsi ka grund flour bana hua he jisme ek room , kitchen and let bath bane hue he . 8 inch ki wall he . Hum ground floor ko toch kiye bina first floor bana sakte he kya ? 2 room with RCC chat . Please suggest kijiye 🙏🙏
Very nice sir
Sir mai ek architecture student hu or apki video se mujhe bht knowledge milti hai 😊
Thanks bro...
Kaha se ho..aap
Mai bhi 1 architecture student hu sir 😁 or ap ki videos bahut help krti hai service ko theeek se smjne mai madat milti hai thanks sir
Cement Ka set say ghar ha Mara usko slabe kaisa dala ja tha ha beam nai ha big heant Ka dewal ha
Aap ko agar khabi moqa mily is tara k kaam karny ka to plinth beam zaroor lagwana
Ye bhai sahb ne pilnth beam nai lagway hein
Very good information sir just👍🏻👍🏻👍🏻
Aap ke sare video helpful Rehte Hain.
Sir isme jo chhat ke upar beam dali gaii h uska load or uske upar jo wall padegi in dono ka load chhat pe to padega hi..
Ha bro but bahut km... maximum load column me transfer ho jayaga...
Best knowledge video 👌
Charo side pe hatch lagage v kiya ja sakta tha, partition wall ko 5inch rakhne se problem hoti kya
Thank you for video. Please tell me is hide beam safe ?? It's interesting design ,I like.
Great sir.
We are going to have such modification. This is helpful..
Nice sir.
Thankyou very much sir 🌹 🙏 🌹
Mera Ghar 2018 me bana,jisme column aur pillers hai,nichey beam h but upar beam ni pada h...
Bahar ki deewar 9inch ki hai, but Andar ki deeware 4 inch hi hai...
Ab jab mujhe in chijo ka knowledge hua toh man bahut dukhi rahta hai,ye sab soch kar please mujhe kuch upay bataye ki mere ghar me majbuti aa sake
hello sir kia yeh possible nahi k sunken area main khanger bhrny ki bjaye hum isi hatch beam per walls utha lain aor jo slab k top ka level hy usi ko floor level man kr us per pcc kr k stone etc laga dain ??? dead load km krny k liye ???
Toh hum is tarah ki beam ka use achi finishing k liye bhi kar sakte hain
भाई साहब concept आपका बोहत अच्छा था बस दो बातें कहना चाहूंगा , एक तो 5:28 पर देखिएगा जो beam है आपका वो column से out है जो की गलत है , beam एकदम center में होना चाहिए और दूसरी बात आप इसमें अगर rcc ceiling ( 12 mm 6" x 6" रिंग , single layer) देते तो ज्यादा अच्छा होता , छत का सारा लोड उस पर आ जाता |
Boht achaa nice
Good information janab
Sir ji agar chajje ke uper wall le jaye to usme aage beam bana le usme koi dikkat to nahi plz reply kar de
Hello sir how are you aap Bohut Achi video bante very nice zabardsta thanks very much information dene k liye
Fine bro .. thanks
Dear sir, mere plot mai 3 feet tak paani bhara hai. Kya ham pump se paani nikal ke footing ka kaam start kar sakte hai.
aap ne beam ka size bataya. aur columns ka size kia hai kaun sa rod laga hai aur kitne distance me columns diya gaya hai maximum distance kitna hona chahiye
Column ke design plan pr depend hai
Thank you making this video
iske upar aap kitni floor or bna skte h hatch beam ke upar. yeh bhi kam normal beam ki tarah kregi. ya uske comparison mai kamjor rhegi.
Hatch beam kya hota hai aur kaha use hoti hai ispar ek pura video banaiye
Ok
Sir aap ka video bahut acha hai ye merey bahut sarey doubt clear kiye hai..... Magar meray site par thora alag type ka challenge hai.....i wish I can communicate you through call or any other means.
sir ek question h aapse ye aapne jo hatch beam ground floor ki slab se uper 6 inch uthai h...m beam uper nh lejana chahta toh beam ki width k equal slab ko todhkar fr jab slab ka reinforcement dikhne lge usi reinforcemnt par beam ki bars niche ki side tie krke beam ko niche hi cast kru aur dono side column se support krna chah raha hu ..ye thk rahega.?????????.i hope you got my question....ye m bas ek room ki width badhana chahta hu...islye krra hu baki deewar k uper deewar ayengi first floor m....i wnt your suggestion...i will wait fr it.. although from my side i have done all the calculations..i want to clear my doubt
Video bahut achchi thi
Jab hum footing k liye suppose 4'×4' ka area excavate karenge tab existing walls ka Kya hoga jo upar hai,isme to hmne sirf column wale area me hi wall todi hai
Pls explain
Old building me hall banana ho? Kya kre ? Aur ooper home?
भाई साहब यदि ग्राउंड और फर्स्ट फ्लोर पर 9 और 14 इंच की दीवारें हो तो क्या हम छत पर हैच बीम को नीचे की दीवाल पर रेस्ट कर के कहीँ भी दीवाल उठा सकते है?
,
Sir tell me about which filler material we use to make floor and hidden beam at same level .
Sir jab patthar lagega tab chhat per load ayega to usse koi dikat to nhi hogi
Hello mera ghr 3 manjil h
Jisme pillars h per beam nahi h
To kya hum ground floor ki kisi deewar ko gira sakte h?
hi sir first floor Pai kaam kara raha hu RB linter hai uspai ground change kerke room banjayge
Interesting.
Sir Khangar or kya kehte Hai Kuch pahchan batao kesi Hoti hai or kya isse wait ni Hoga lenter pr
Sir , hatch beam ke upar naya collum le skte hai kya
Bim ke uper gate lagega to uncha ho jayega na pharsh se
Hi Aman ,but you didn't gave plinth beam to new columns ,one more thing if the quality of old slab is not good then it no use to give hatch beam and all am I correct?
Kya technically yah slab lot sear karega?
Kunki normally desi type ke house constitution work Mai people desi civil work karte hai, Es type ke jugad working ko nhi kiya jaye , Kunki yah dekhna hoga ki lend kis zone mai aata hai, or soil report Kya hai.
Sir lenter par. Room par Dewar laga sakte ha room lenth 11 feet ha window 8,feet. Lagana ha
Bhai.. jo ventilation k liye shaft bnai jati h ghr me uspe video bnao.. hr room or kitchen, bathroom etc me kaise bnaye..
Ok
sir kya aap plan bhi banate ho ghaer ke 30x60 ka plot hai
Sr. Bina column ke beam dena ho to possible hai ??
sir RB linter po hachmi beem dalko kahi sai bhi wall ker sakte hai please reply
Sir kya hum heatch beam dene se be chat ke upper load nehi ayega sir please reply
Hy sir.... Ek band makan h to..... Usme ek L type ki diwar h to..... Usko thod k.... Mkan k aaage bnani h........ Kuch btaye sir... Plzzzz
Sir nice information .....mere Ghar me vertical beam hai par horizontal beam nahi Dale hai Abi to ground floor hai lekin upari manzil banani ho to Kase beam provide Kare
Old building me Naya jitni v column dalenge ,unme ground se niche inter column belt banana nehi padega?
Dear sir,
Prana ghar ki dewaar mein beam kaisa de aur kin -2 bato ka khayal rakha us per ek video zaroor banya
Very informative video.....Keeps going...
Thanks
Hello ur amazing. Mje apne ghar ke piche baramde me bathroom banwane hai. Ek ke upar ek. Or wo piche wale kamro se attach honge. Uska kya procedure hoga...
Aap KR sakte hai... simple hai
Maine cantilever pe edge beam nehi to aisa kar sakte hai 1st floor pe
Sir me video apka dekhta hun krpyaye batay ki niche se 2 feet upar beem wali d p c kaiae dale bena jyda dwae nuksanpahuchay aur beem kaise dale h am upar ka lenter tod kar 2 feet upar lenter dlna chah te he
Kya beem chat ke upar se daal sakte hai
Hello sir,
1 sir beam main lagne wala ring size kitna hoga.
2 Aur jeetne bhi deewar honge upar sab ke niche beam dena hain kya
3 2 mtr main jo beam lagega woh kya niche diye beam ke saman hoga kya.
House lifting and shifting घर को ऊंचा करवाएं बीम डलवाया=6201962545
Sir, Maine 6 mahine pehle chath ke upar 2 bedroom banaliye hain maestry se, lekin jaise ki aapne video me dikhaya ki hatch beam ke upar load de rahe hai, humne chath ke niche column hai to tikh column ke upri hisse pe load diya hua hai toh koi dikkat to nahi na sir?? Pls reply
sir hatch beam to plan ke hisab se dale he wall to wall sari wall bhi beam pr hi run kr rhi he colum nahi dale the aur hum ko bs yahi floor banana he koi dikkat to nahi he bs yahi pata krna cha rha ho
Very nice
floor finish se roof par aur load aa jayega toh wo safe rahega roof k liye?...roof porani hai toh collapse bhi ho sakti hai
Sarvesh Patil nhi bro..floor finish ke leye aap ko very light material use krna Hai filling ke leye as.. Khangar (aac brick block waste) and then stone se finish KR lo ..Kyu ke old roof PE keval stone ka he mostly load hoga ..1st floor ke wall ka load column aur beam PE jyada hoga..thank for comment..
Ooh thanks ✌
भीम के ऊपर ईट की दीवार 9 इंच या 4 इंच की खड़ी की है?
Very nice information.....but sir I have some doubt in my old house condition....sir Mera Ghar surkhi chuna ka hai....60 yr old....in good condition ...but some family problem ki wajah se....usme kuchh construction karana par raha.....surkhi ke upar ....mujhe RCC slab daalna hai....niche se column nikaal ke.....beam ke depth ka issue nahi samajh AA raha.....aap apna Instagram,Facebook ya Whatsapp number dijiye....aapse baat karunga.....if problem aayega banate time..... January me banana hai...after corona issue ....
Very nice video
Hi sir ,chhat ke balkoni ye parapet 2.5 feet bahr h uske upar se room work kr sakte h ye phir beam dena hoga ya nai
Sir mene uper wale porsan me lenter ke upar dewar khdi kar di hai kewal hazmi beam diye hai. Koi nuksan to nhi hai
Sir mera contractor slab pe hatch beam nhi daal rha, seedha first floor ka brick work start kr rha hai?
kya woh thik kr rha hai.. slab almost 25 year purani hai ?
Sir mera ghar dealer ka bna hai aspas ki wall 4 inch ki hai aur bich ki ek wall 9 inch ki hai chatt pr koi bhi beam nahi hai upr bnana ho to wall ke upr hi bnana hoga kya ?
Bro is baare me Bina dekh ke main bhe Kuch nhi bol sakta hu...
Existing slab par khangar ka load extra badne par koi dikkat to nahi hogi...
Khangar ke weight bahut km Hota Hai...koi problem nhi hogi
सर, मेरा ग्राउंड फ्लोर 2016 में बन गया था और उसमें कॉलम तो पड़े थे पर लेंटर से पहले लटक बीम नहीं पड़ी थी, ग्राउंड फ्लोर की खिड़कियों और दरवाजों के ऊपर फर्श से 8 फीट की ऊंचाई पर डोर बैंड पड़ा था पूरे मकान में, उसके बाद 3 फीट की चिनाई हुई और सीधे ईंट के ऊपर लेंटर पड़ा गया। ग्राउंड फ्लोर के कॉलम लेंटर से ऊपर 2 फीट निकले हैं, अब फर्स्ट फ्लोर की प्लानिंग चल रही है, ग्राउंड फ्लोर के कॉलम के साथ हम फर्स्ट फ्लोर के कॉलम खड़े कर रहे हैं, पर अभी उनमें कंक्रीट नहीं भरा है, तो मैं यह पूछना चाहता हूं कि हमें ग्राउंड फ्लोर के लेंटर के ऊपर हैच(फ्लैट) बीम देनी पड़ेगी या नहीं।
और सर हमारी ज्यादातर दीवार तो नीचे वाली दीवार के ऊपर ही आ रही हैं पर 3 दीवार ऐसी है जो नीचे वाले कमरों के लेंटर के बीच में आ रही है तो क्या करें?
Sir please reply fast......... urgent
5 ft ki gali h 1st floor pr us gali ki saize ko chhota krna h to kya bina hedge bim k brick work krenge to koi problem hogi
Agr slab ki cutting kr k kren gy to ground floor ki slab ki strength kam ho jay gi plz ans me
Agar flat lanter par 10 foot ki uchai se cooler gera jaaye to kamjori aayegi lanter me ???
Hello sir... nice information. I had a doubt.... sir, insted of using conventional coloumns and beams, can we use ISMB 250 or 150... depending on the load above..? Even for the hatch beams, can we use same ISMB?. Please clarify.
Building lifting and shifting building main beams and columns dalwai=6201962545
Kia is beam ka aik corner free reh sakta means cantilever??kion kay video may hatch beam free hay balcony ki side say mean kisi colum say connect nai hay..??
Agar kisi ghar me sirf iit se ghar bana ho to uske uper naya bim dal kr new ghar bana sakte h
Nhi
Sir..jab beam ko cast kiya jata h tab beam ka self wt. Old roof pr hi hota h.... Matlb beam poori tarf old roof pr hi rest kr rhi h... What concept y?... Ya to old roof ko beam se link Kiya Jaye tab to possible h ki beam old ka weight bear Kare.....
I confused sir......
Sir Bim or slab ek satha dalini chahihea ya first Bim next slab
Teen manjili bangeya kya esye type karke naya pillar dey sakta hu majbhoot key liye, sir
Sir mai bhi110 saal puraane makaan me chat par kmre. Banwa raha hu , thekedar ka kasa padta hai ki upR kamre ki base me jaala aur jumper .Plus beam ke bich me taaki upar ka l.oad nichr naa. A ye haalanki upar kamre ban a chuka hai abhi ties aur palastar baaki hai niche koi problem na ho kya karu
Very informative....👍👍👍
sir 9inch k hidden beam pr 9inch ki brick wall de sakte h kya 14ft ka distance h
9" brick wall na de to jyada acha hoga..
Sir ek question hai kya jo foundation se column uthta hai wo puri height tak jaye jaroori hai ya fir alag se kisi beam ke uper bhi column khada hota hai