HOW / WHEN TO ADD OIL TO AIR CONDITIONING COMPRESSOR

Поделиться
HTML-код
  • Опубликовано: 12 дек 2024

Комментарии • 71

  • @cucumbersalad9063
    @cucumbersalad9063 Месяц назад

    man you always posted exactly what I need to know years before I need to know it!

    • @D2DNYAC
      @D2DNYAC  Месяц назад

      Thanks for watching

  • @MurtezaAFG
    @MurtezaAFG 6 месяцев назад

    Fantastic video; benefiting from this 3 years later. God bless

    • @D2DNYAC
      @D2DNYAC  6 месяцев назад

      Thanks for watching

  • @wd8557
    @wd8557 3 года назад +5

    That must have a bad plug heater, I didn't see a crank case heater. That foaming is from liquid refrigerant getting under the COOL oil when the system is off. Then when it start's it pushes the oil out into the system. The heater helps to prevent that by keeping the oil HOT.

    • @2020joeyd
      @2020joeyd 2 месяца назад

      Crankcase heaters are only needed if the compressor is outdoors and runs all year long and during cold ambient temperatures.

    • @wd8557
      @wd8557 2 месяца назад

      @@2020joeyd 100% not true.

  • @jeffreygreene4519
    @jeffreygreene4519 2 года назад +2

    Very informative, I thoroughly enjoyed the narration! Thanks

    • @D2DNYAC
      @D2DNYAC  2 года назад +2

      Thanks for watching friend

  • @bashirbeladjal4779
    @bashirbeladjal4779 Год назад

    Thanks for the detailed explanation

    • @D2DNYAC
      @D2DNYAC  Год назад

      Thanks for watching

  • @prithwishdey6708
    @prithwishdey6708 3 года назад +1

    Sir please discuss me aproch temperature on air cool chiller. Water cool chiller aproch temperature vs aircool chiller aproch temperature.

  • @celiaknight1482
    @celiaknight1482 3 года назад +3

    I can't figure out what you are doing!!! Thanks anyway!

  • @bigkidband911
    @bigkidband911 2 года назад

    I have a question- I have a rheem system. The compressor runs fine when temps outside are in the upper 70s, but once temps are in the mid 80s the compressor will run for a while and then shut down. The air handler is still blowing air. I’m assuming the scroll compressor is going into protection mode. Could old oil or warm out oil cause this issue?
    Thanks!

    • @D2DNYAC
      @D2DNYAC  2 года назад

      How is your refrigerant charge?

    • @bigkidband911
      @bigkidband911 2 года назад

      @@D2DNYAC good

    • @D2DNYAC
      @D2DNYAC  2 года назад

      Is the compressor over heating?

    • @bigkidband911
      @bigkidband911 2 года назад

      @@D2DNYAC I’d assume, but not sure. I ran it yesterday when it was 85 outside. Ran fine for half the day then compressor shut down. It’s 75 degrees out side right now, so I turned on the ac. Had to go out and push the reset button on the compressor. Been running fine for an hour.

    • @D2DNYAC
      @D2DNYAC  2 года назад

      Ooh, what button are you resetting?

  • @RJMaker
    @RJMaker 3 года назад +6

    Looks like someone was struggling with those braze joints.. :-)

    • @D2DNYAC
      @D2DNYAC  3 года назад +1

      Indeed 😂 that’s why I took over

    • @sjefoekel6058
      @sjefoekel6058 3 года назад

      @@D2DNYAC also something dripping from discharge line.

  • @robertg9563
    @robertg9563 2 месяца назад

    how to know how much oil the compressor have if it doesn’t have a sight glass?

  • @ronhanish
    @ronhanish 3 года назад

    on a typical 2 ton older r22 unit how much oil approximately for system? 25000 btu system.?

    • @D2DNYAC
      @D2DNYAC  3 года назад

      @ron hanish Hard to say if the compressor doesn’t have an oil sight glass, you should be able to determine the oil type and quality from the name plate on the compressor! Or by using the compressor make, model and serial through the manufacture! Or by using the equipment make model or serial and contacting the unit manufacturer

    • @richardromero1736
      @richardromero1736 Год назад

      Install a side glass on it

  • @Ivan-vv6nd
    @Ivan-vv6nd 3 года назад

    So oil should be until half of glass When compressor working or when compressor not working

    • @D2DNYAC
      @D2DNYAC  3 года назад

      Not working!

  • @vigneshwaran6638
    @vigneshwaran6638 2 года назад

    Danfoss compressor oil in sight glass There is no fluctuates during operation. Please advise what is the issue

    • @D2DNYAC
      @D2DNYAC  2 года назад

      Hey friend I don't understand what you are asking!

    • @vigneshwaran6638
      @vigneshwaran6638 2 года назад

      @@D2DNYAC Dear.. The danfoss compressor is running. But the oil is ideal in sight glass.

    • @vigneshwaran6638
      @vigneshwaran6638 2 года назад

      @@D2DNYAC Oil no circulation during operation. Please let me know what is the problem

    • @D2DNYAC
      @D2DNYAC  2 года назад

      Oil problems is usually a result of 3 things , low back pressures, low oil, faulty oil pump. So if you add oil to the proper levels while the compressor is off and then when you run the compressor the levels remains low its a oil circulation problem

    • @vigneshwaran6638
      @vigneshwaran6638 2 года назад

      @@D2DNYAC thank you Dear.. 😊

  • @LatinTurkNYC
    @LatinTurkNYC 3 года назад

    Nice video. Thank you for the info.

  • @prithwishdey6708
    @prithwishdey6708 3 года назад +2

    How to change oil in rotary compressor?

    • @D2DNYAC
      @D2DNYAC  3 года назад +1

      If it’s hermetically sealed with no oil port at bottom of compressor, then Recover the refrigerant disconnect the pipe and drain it through suction pipe and add it back through suction pipe of compressor , the amount and type of oil should be on the sticker on the compressor.

  • @mamaspuput8860
    @mamaspuput8860 3 года назад

    I have 1.5 hp split a/c system, the compressor gets too hot after half an hour, current goes up to 10 amps, then the compressor shut down, how do I fix it?

    • @D2DNYAC
      @D2DNYAC  3 года назад

      If it’s actually pumping / running check and verify the electricals power supply etc is good if so, if head pressures is not high, then compressor is bad, it will probably fail a Meg test.
      If it doesn’t run /pump try using a hard start kit if it doesn’t run then the compressor is bad

    • @mamaspuput8860
      @mamaspuput8860 3 года назад

      @@D2DNYAC the head pressure is good, when its off, the pressure is around 250-300psi, and when its pumping, the pressure is around 140.

    • @mamaspuput8860
      @mamaspuput8860 3 года назад

      what is meg test

    • @D2DNYAC
      @D2DNYAC  3 года назад

      What refrigerant?

    • @mamaspuput8860
      @mamaspuput8860 3 года назад

      @@D2DNYAC r32

  • @axelbelancourt
    @axelbelancourt Год назад

    if a compressor seizes due to being low on oil, what's the next step?

    • @D2DNYAC
      @D2DNYAC  Год назад +3

      Replace the compressor

    • @aldwinmacatbag2295
      @aldwinmacatbag2295 9 месяцев назад

      ​@@D2DNYACdo need to flush the system when replacing a sieze compressor?

  • @syedbasheer8210
    @syedbasheer8210 3 года назад

    👌👌

  • @Rayees-h8g
    @Rayees-h8g 3 года назад

    Me too Hvac ✋ tech.

  • @pram3384
    @pram3384 3 года назад

    Show how to troubleshoot a compressor

    • @D2DNYAC
      @D2DNYAC  3 года назад

      ruclips.net/video/yZAgh1O0OVA/видео.html

  • @susantoresas
    @susantoresas 3 года назад

    sir how to add oil to compresor you can referensi vidio

    • @D2DNYAC
      @D2DNYAC  3 года назад

      ADDING OIL TO HVAC / AC COMPRESSOR

    • @susantoresas
      @susantoresas 3 года назад

      @@D2DNYAC ac kompresor same your this vidio

    • @D2DNYAC
      @D2DNYAC  3 года назад

      ruclips.net/video/5foUHmIEtY4/видео.html

    • @D2DNYAC
      @D2DNYAC  3 года назад

      Click the link to see me adding oil

  • @BishopNiaronHyatt
    @BishopNiaronHyatt 10 месяцев назад

    Real yardy

  • @jasonclements8873
    @jasonclements8873 2 года назад

    Those welds look like shit. Yep Its leaking.

    • @D2DNYAC
      @D2DNYAC  2 года назад

      lol 😂 yea indeed they do