Residential Building Code Violations (Part 5)

Поделиться
HTML-код
  • Опубликовано: 9 июн 2024
  • #inspection #residential #building #codeviolations #2018IRC

Комментарии • 31

  • @JohnQPublic345
    @JohnQPublic345 2 месяца назад

    seeing this makes me so much happier with myself. ive been a contractor for 30 years, and ALWAYS strive for a perfect job- up to all codes

    • @PPG1967
      @PPG1967  Месяц назад

      I appreciate your feedback, and thanks for watching.

  • @boobo0
    @boobo0 6 месяцев назад +1

    Good stuff per usual Renaldo! Thank you!

    • @PPG1967
      @PPG1967  6 месяцев назад

      I appreciate your feedback!!!

  • @user-ee2ts4ug7s
    @user-ee2ts4ug7s 6 месяцев назад

    Thanks for the video. It’s very helpful in my job!

    • @PPG1967
      @PPG1967  6 месяцев назад

      I appreciate your feedback, and thanks for watching.

  • @bjmack1537
    @bjmack1537 Месяц назад +1

    Thanks for the great information. I'm new to your channel. I have a 3 year old townhouse and just watching your channel have seen a couple of violations. I would like to get this in writing to address the builder with.

    • @PPG1967
      @PPG1967  Месяц назад

      Where are you located?

    • @bjmack1537
      @bjmack1537 Месяц назад

      @@PPG1967 Georgia

    • @PPG1967
      @PPG1967  26 дней назад

      Everything is in the 2018 IRC

  • @splitsuckle
    @splitsuckle 6 месяцев назад +1

    Hi Renaldo I am a new viewer. I want to ask you something regarding windows and doors. I live in Greenville, South Carolina. In a year I would like to begin my build as owner/builder. I have been woodworking as a hobby for a while now and I thought this would be a great opportunity to build custom doors/ windows (including the glazing) . My question is; if I do it myself I won’t be able to provide the sticker on the windows/doors which include U value/ R value and other specs which I see on all the commercial units in stores. Would this cause issues during inspection ? Thank you and I appreciate all of your content !

    • @modelhomesllc1563
      @modelhomesllc1563 6 месяцев назад +1

      I would just by my glass Separately that's already rated and then install it in the door or window customs

    • @alexjones7845
      @alexjones7845 6 месяцев назад +1

      It depends upon the local government rules. Some jurisdictions are very picky and will require full energy analysis to be completed at the planning stage when plans are submitted to the planning department (like throughout a state like CA). In those areas they would typically confirm many materials (specifically windows) used in the construction meet that plan design and energy requirements.
      However, other parts of the US are much more relaxed and may not even care about windows, except maybe to require that they are double pane. If I were in your situation I would just speak with the planning department and ask for their window and door requirements on a new build.

    • @PPG1967
      @PPG1967  6 месяцев назад

      You have two excellent responses.

  • @robdavidson993
    @robdavidson993 2 месяца назад

    If door swings out over stairs then landing is required. Grabable handrail required at stairs. Engineer to address bracing at deck.

    • @PPG1967
      @PPG1967  2 месяца назад

      You must know I like to respond to ignorance. Do you have a copy of the IRC???... did you understand the video??

    • @PPG1967
      @PPG1967  2 месяца назад

      Where was the door swinging over stairs in the video?...A graspable handrail is required on one side for (4) or more risers. An engineer wouldn't touch that deck for $1 million dollars.

  • @danniegoodson8212
    @danniegoodson8212 6 месяцев назад

    currently studying for my limited/SFD license, is there anything that you can recommend or send to study that will specifically be on the test?

    • @PPG1967
      @PPG1967  6 месяцев назад

      Where are you located??... what code book has your state adopted??

  • @brianclark1970
    @brianclark1970 6 месяцев назад

    Im taking building level 1 certification in december. I am studing but could you start providing the correct method. it would help.

    • @PPG1967
      @PPG1967  6 месяцев назад

      Correct method??.. what are you talking about??

  • @constructivainspections
    @constructivainspections 6 месяцев назад +1

    tha hell goin on with that sheathing? maybe the framers didn't have enough to drink yet.

    • @PPG1967
      @PPG1967  6 месяцев назад

      Your guess is as good as mine.

  • @kathywilliams903
    @kathywilliams903 6 месяцев назад

    I'm looking to hire inspector in Kansas City for myself I don't trust inspectors did no contractors do you know any work for individuals

    • @PPG1967
      @PPG1967  6 месяцев назад

      Check with your local or city building department.

  • @mrxsneak2693
    @mrxsneak2693 4 месяца назад

    2:43 more nails means more better right?😂

    • @PPG1967
      @PPG1967  4 месяца назад

      Most of the time.

  • @brianclark1970
    @brianclark1970 6 месяцев назад

    Yes sir some times you describe what the code should be

    • @PPG1967
      @PPG1967  6 месяцев назад

      I'm confused as to what you're asking for.... I'm giving you real-world in the field examples, I'm giving you code sections ....what else are you needing???

    • @PPG1967
      @PPG1967  6 месяцев назад

      You need help comprehending the code???

    • @PPG1967
      @PPG1967  6 месяцев назад

      I never post what the code should be...I give you what the code is.