One way slab Vs Two way Slab | மடிப்பு கம்பி Crank rods | Deekshi Homes

Поделиться
HTML-код
  • Опубликовано: 13 авг 2022
  • One way slab vs two way slab | Roof slab reinforcement | Roof reinforcement in detail | Why to provide Cranks in roof reinforcement
    Deekshi Homes
    9940 667 567

Комментарии • 50

  • @ramanlaxman9536
    @ramanlaxman9536 Год назад +6

    எளிமையாகவும் புரியும் படி சொன்னதற்கு நன்றி 👍🏻

  • @hariharan-qv4ch
    @hariharan-qv4ch Год назад +8

    The way you explain . Even a non engineering guys also understand. It's help a lot . Thank you 😊

  • @pragha9113
    @pragha9113 Месяц назад

    Very informative video ,simply awesome,clear explanation 💐

  • @govind9329
    @govind9329 Год назад +1

    Very Nice. Well explained 👏 👌

  • @kumaragurug4698
    @kumaragurug4698 8 дней назад

    Very fantastic 👍👍

  • @boobalchandran4613
    @boobalchandran4613 Год назад

    Very very superb explanation Er. Tq

  • @elumalaik8017
    @elumalaik8017 Год назад +1

    Thank you so much sir very Usefull video

  • @sureshm8522
    @sureshm8522 Год назад +1

    Simple and clear explanation

  • @dvmuthukumarveluswamy9361
    @dvmuthukumarveluswamy9361 Год назад +2

    Really Good explanation bro... Your knowledge transfer would be appreciated 👍

  • @jenilia7339
    @jenilia7339 Год назад

    Excellent sir...

  • @brittojohn1844
    @brittojohn1844 3 месяца назад

    Very useful Thanks

  • @tilakareswaran576
    @tilakareswaran576 Год назад

    Useful sir 👍👏

  • @rxraja441
    @rxraja441 6 месяцев назад

    sema explain anna

  • @newtoncalls
    @newtoncalls Год назад

    Hari brother your voice sounds great 👍 when you are not facing the camera

  • @priyasunil9738
    @priyasunil9738 Год назад +2

    Do you undertake repair works for a commercial building?

  • @praveenkumar-fo6sw
    @praveenkumar-fo6sw Год назад +2

    What would happen if we design a one way slab instead of two way slab room sizes are 17*11,10*10,7*9&9*8

  • @iyyappang5444
    @iyyappang5444 9 месяцев назад

    Super

  • @makeiteasy9723
    @makeiteasy9723 2 месяца назад

    Thanks for info. for 10 ft x 6 ft room , 10/ 6 , ~ 1.6 so 2 way slab . for small room like this main and distributor rod 8 mm diameter is OK ? how it is decided for how much length 10 mm dia or 8 mm dia is OK ? Thanks

  • @Rajapostman6031
    @Rajapostman6031 Год назад

    Veettukku vasthu outer measurement pakkanuma illa inner measurement pakkanuma sir😊

  • @swathi.n8871
    @swathi.n8871 Год назад +3

    Hi Hari sir. Nice explanation. We are extending an additional room in our old house. Our new room is 10*8. Oru engineer said as area is small , crank on two sides of Lx (8 ft) will be enough. We have used paste to concel with old building on the Ly end (10ft end) ... Will this create any big issues?

    • @deekshihomes
      @deekshihomes  Год назад +1

      From your data there is no issues in this

    • @swathi.n8871
      @swathi.n8871 Год назад

      Thanks for the confirmation... No issues because the area is small? The crank concept of one way slab is followed in our two way slab room.

    • @deekshihomes
      @deekshihomes  Год назад +3

      Yes as the area and load is very minimal not to worry about it

  • @nagendranradhakrishnan4764
    @nagendranradhakrishnan4764 Год назад

    How to calculate the Crank distance is 1/3 or1/4.explain pl.

  • @ariharan27
    @ariharan27 Год назад

    Crank point evolo vaikkanum sir

  • @_kid_kurama_43111
    @_kid_kurama_43111 Год назад

    Tamilnadu la enga la ne v2 kati kudukiringa?

  • @veeramaniselvaraj
    @veeramaniselvaraj 5 месяцев назад

    One way slap க்கு 12mm×10mm பயன்படுத்தலாமா சார்?

  • @isaacraj5339
    @isaacraj5339 Год назад

    Our hall room is 16*10 but crank also done and on center of both concealed beam also given on full length of room will this beam create any problems

    • @deekshihomes
      @deekshihomes  Год назад

      Kindly share images in whatsapp @ 9940 667 567

    • @isaacraj5339
      @isaacraj5339 Год назад

      @@deekshihomes it is already finished but we are going to build first floor so only

  • @dharanidhamarai2545
    @dharanidhamarai2545 Год назад

    🙏👍👏👏👏👏👏🤝

  • @naveensj6
    @naveensj6 Год назад

    Bro , how many rods are required and at what inch we should place at anh methods kindly reply bro

    • @naveensj6
      @naveensj6 Год назад

      What size rods are required?? And what are their necessities??

    • @deekshihomes
      @deekshihomes  Год назад

      For those you need to get structural drawing

  • @RENACONBUILDING
    @RENACONBUILDING 10 месяцев назад

    Crank degree + crank அடிச்சதுக்கு அப்புறம் டிஸ்டன்ஸ் எவளோ இருக்கனும் sir

  • @KrishnaMoorthy-mq1jc
    @KrishnaMoorthy-mq1jc Год назад +1

    Super but Tamil la sollunga

  • @VenkatVenkat-pm2em
    @VenkatVenkat-pm2em Год назад

    2bhk plan &structural design kidaikuma

    • @deekshihomes
      @deekshihomes  Год назад

      Reach us on whatsapp for drawings. 9940667567

  • @thirumalaivasant9322
    @thirumalaivasant9322 2 года назад

    Sp34 code book bro

  • @ajithcaxton7023
    @ajithcaxton7023 Год назад

    Sir any vacancy for your construction company

    • @deekshihomes
      @deekshihomes  Год назад +1

      Mail resume to deekshihomes@gmail.com

  • @nilamakillifestyle4558
    @nilamakillifestyle4558 Год назад

    Sir marbles fix pannanum enna mathiri steps follow pannanum

  • @ismailkahn8607
    @ismailkahn8607 10 месяцев назад

    நான் மதுரை பக்கம்,,, உங்க நம்பர் கிடைக்குமா

  • @muthumani1170
    @muthumani1170 Год назад

    Unga num solunga bro

  • @Rajapostman6031
    @Rajapostman6031 Год назад +1

    Unga contact number kedaikkuma sir

  • @tilakareswaran576
    @tilakareswaran576 Год назад

    Useful sir 👍👏

  • @makeiteasy9723
    @makeiteasy9723 2 месяца назад

    Thanks for info. for 10 ft x 6 ft room , 10/ 6 , ~ 1.6 so 2 way slab . for small room like this main and distributor rod 8 mm diameter is OK ? how it is decided for how much length 10 mm dia or 8 mm dia is OK ? Thanks