Current Transformer Concepts| CT Burden | CT Accuracy Class

Поделиться
HTML-код
  • Опубликовано: 21 ноя 2024

Комментарии • 42

  • @amazingvideos673
    @amazingvideos673 3 года назад +5

    Wow first time ct burden is explained in simpler manner

  • @asmafarid2939
    @asmafarid2939 3 года назад +2

    Too good. Wonderful explaination

  • @nuthalapatisudhakararao3515
    @nuthalapatisudhakararao3515 2 года назад +4

    Your way of explanation is awesome thank u ...keep more topics ..

  • @hfahFun
    @hfahFun 3 года назад +2

    Stunning well done

  • @sanjayhake6872
    @sanjayhake6872 Год назад +1

    Nicely explained

  • @sohailjanjua123
    @sohailjanjua123 3 года назад +2

    Hi, I like your lecture. Thanks

  • @manojillangasooriya3590
    @manojillangasooriya3590 11 месяцев назад

    good one. thank you.

  • @macpeleanyanwu745
    @macpeleanyanwu745 2 года назад +1

    This is an excellent tutorial, keep it up

  • @amazingvideos673
    @amazingvideos673 3 года назад +1

    Outstanding way of teaching

  • @wakh6260
    @wakh6260 3 года назад

    Perfect as usuall

  • @suryasreedharreddy2277
    @suryasreedharreddy2277 3 года назад

    CT operating in normal mode then fault current appears in load ... how can we reduce fault current on primary side by effective changes on Secondary side... what are the changes possible on Secondary side to reduce fault current on primary side

  • @sushilkoch8625
    @sushilkoch8625 Год назад

    Thank you.

  • @yibeltalassefa3619
    @yibeltalassefa3619 2 года назад

    Thanks a lot

  • @ahmadmohmed4448
    @ahmadmohmed4448 17 дней назад

    what he means by"CT Secondary should never be opened"? Is it even possible to open it Physically?

    • @electricallectures
      @electricallectures  17 дней назад +1

      I mean to say secondary connection should not be open while CT is energizes. And it can also be possible to open CT physically as in Clampmeter

    • @ahmadmohmed4448
      @ahmadmohmed4448 17 дней назад

      @@electricallectures thanks a million, god bless you

  • @Ragavenutb
    @Ragavenutb 3 года назад +1

    Hi,if data markings on the CT's disappear how would one determine the correct ratio? Thank You.

    • @electricallectures
      @electricallectures  3 года назад

      Then you have to do it by hit and trial. One thing for sure the output is always 5. So by measuring secondary current and primary you can compute ratio

    • @Ragavenutb
      @Ragavenutb 3 года назад

      @@electricallectures so i basically run 100a through the line and measure Ct output amps. If its 2.5 its primary is 200a. But due to impedance and accuracy class, output can't be accurate right?

  • @edupros9028
    @edupros9028 3 года назад

    From which software u make this video

  • @abidkayani336
    @abidkayani336 3 года назад

    👍

  • @suryasreedharreddy2277
    @suryasreedharreddy2277 3 года назад

    What happens on primary side current when burden increases on Secondary side

    • @electricallectures
      @electricallectures  3 года назад

      No effect on primary but if burden exveed the ratio will be disturbed and so as secondary current

    • @suryasreedharreddy2277
      @suryasreedharreddy2277 3 года назад

      If the Secondary winding is replaced with reactance instead of short circuit after sometime then what happens on primary side current

  • @Artistic_S0ul_
    @Artistic_S0ul_ 3 года назад

    I have a question. Please could you tell me, what would happen if the flow primary current is 300 A permanently, and the ratio CT is only 200/5 A? Thanks by the answer.

    • @electricallectures
      @electricallectures  3 года назад

      Ct will saturate and 5 A will continue to flow

    • @Artistic_S0ul_
      @Artistic_S0ul_ 3 года назад

      @@electricallectures Thanks a lot by the answer.

    • @fabianm.2982
      @fabianm.2982 2 года назад

      @@electricallectures I don't agree, please elaborate further. There are times when you can set the pick to be above the 100% rating, which is 5A. I have seen the CT's rated 600/5A and relay set at 1.2 of the primary current. Is that a wrong practice or what?

    • @electricallectures
      @electricallectures  2 года назад

      Absolutely wrong. Ct can only produce 5A. As far as pickup is concerned , 1.2 can be set if the maximum primary current is 600. Let say ur relay is supposed to trip @400A which is 1.2 times. Now ur ct is 600/5 and it will work in this situation

  • @debarpanchanda7506
    @debarpanchanda7506 3 года назад

    Sir could you please explain any practical application or uses of reduction of CTR...? It's will be much beneficial for me..Thanks in advance sir.. 🙏🙏🙏

    • @electricallectures
      @electricallectures  3 года назад

      Do you want to ask usage of CT . I dont actually understand your question. Reduction of ctr

  • @Dario-ox6zi
    @Dario-ox6zi 3 месяца назад

    I need 1000/5 but 0.3 burden 15va

  • @سبکچھ-ش4ل
    @سبکچھ-ش4ل Год назад

    200/2 farmola 😊

  • @michelvidallo7288
    @michelvidallo7288 5 месяцев назад

    i cannot understand you bus or bar type?? wtf