All AC FAULTS and solutions | ऐसी के सभी फॉल और सॉल्यूशन एक ही वीडियो में
HTML-код
- Опубликовано: 5 окт 2024
- All AC FAULTS and solutions | ऐसी के सभी फॉल और सॉल्यूशन एक ही वीडियो में
all ac faults and solutions
ac repair
ac repair training
ac repair car
ac repair man
ac repairing course in hindi
ac not working
air conditioner not working
word of advice tv
#All_AC_FAULTS_and_solutions
inverter ac ke bare me fault and solution bataiye full video sir
Ok brother
Nice information sir ji. Thank you
Very nice video. Sir please guide kare compressor not working for split ac. Capicitor changed.
Thanks bhai for fault find out and repair.
I'm ac technician from pune, great information sirji
Sir no chahiye aapka
Amresh ji namskar mai chhotan ji boll raha hu hamare pass indoor split ac hai indoor chal raha lakin outdoor me fan aur compressor dono nhi chal raha hai but jo contractor laga huwa hai uska battum ham pres karte hai to pura system chalane lagata hai kya problem hai explains kijiye
Aaj aapka video ready hai
बहुत बढ़िया जानकारी दी है, indepth knowledge AC के बारे मे। आप का experiance दिख रहा है।👍
Thanks 🙏
@@MyChannel-c6l vvv
Thank you sir ji keep making videos.
Thanks amresh ji its time for revegion to start the job in India season starts A/ C DT 22/3/24 Happy holi dear
Apne meri bahut help ki h think you❤ sir
सर आप बहुत अच्छी तरह से समझते हो❤
Apka samjana moje bahut accah lagta hai, thank you
Blower motorka speed sahi hai ya kam hai ye kaisa pehjaanengey sir
all video are good. I have a hisense split ac inverter, indoor turn on but sometimes outdoor does not work and there is no sound. Another day when I switch on, both indoor and outdoor work. Refrigerant is100psi (R410A}. Please help.
Zamil ka ac chal rahaa h but cold nahi kr rahaa h aur out door me braber pressure and ampier Le rahaa h pls btaye kya problem ho sakti jbki uska indoor clean kr diya h
Thanks sir ji
Hamne 1 sal pehle 2 ton ka ac office ke liye install kiya tha. Office size 18 x 12 x 10 feet ka he. Lekin mera ac me 15-20 bar company ka technician ko bulaya. Vo ate he ok karke jate he. Lekin 4-5 din sahi chalta he. Uske bad cooling bandh ho jata he.
1 sal me itni bar service karane ke bad bhi problem solve nahi hota.
Thank you sir apne hamari help ki
1.5 × ki speed se dekhi fir bi sir ap itna slow bolte ho😂
😂😂
Sahi pakde h 🤣😂
Sir pda ke nhi bolte issliye
Ha bhai
😂😂😂😂😂
धन्यवाद
Bahut acchi video banai aapane sar❤❤❤
Superb bhai
Bhai compressor aur capacitor fan moter ki open me wiring ki vdo banao
Ok bro
Ye bath ssach hai ki, har parts ka num oar kam janna bahut jaruri hai, konsa patska konsa kam hai janna parega, tou jankari milega,
Nice information thanks 👍👍👍👍
Sir aap great hai ❣️
Nice video 💫
bahi E3 problem kese tihk kare.....bahi pili is pe video banao
Room senso aur coil sensor check karo
Bhai cashcat ac me ko power diya to display sahi cooling number deta hei thore derme fan band hota hei or display me 33 number aata hei remot botton ghstayegato nahi ghata hei kya faults hei?
Thank q Sir jii
Nice vedio sir great man😊😊
Mere window AC me 5 second 10 second ke liye compressor chalta h fir off ho ja Raha h...
Washing ho chuka hai, Capiciter thik h... Kya problem hoga plz reply me...
Sar Indore bolero motor kyon slow ho jata hai iske video banaaiye
Sir outdoor ke senser ke bare bataye sir
Thank you so much 😊😊😊
sir 2 ton ka A C ges usme r nig me 55 he lekin jb hm ampiyr mitor lga kr dekh rhe he to 11 .se 12 fir 13 fir 14 le rha he le kin sekshn pe aich aa rhi he or cooling coyl pe bhi aaic aa jati he kiya fault he btana sir
Ac out door me service wall discharge line me kyu nahi rahta kisi out door me rehta hai 2 service wall please reply i am wait
Very Very nice dada❤❤❤
Bhut accha samjhaya apne sir
Ham Bole Hain sar split AC Mein E7 ka problem bataiye solution bataiye
Very informative video sir
Sir all faults ka practical vdo bana ke daloo plzz
Fridge ki discharge line Agar Thandi rahti hai to kya Kami ho sakti hai
Outdoor pay gas pressure Sahi bata raha hai pipe Thandi ho rahi hai aur nahi IC a rahi hai Fir Bhi Indore calling Nahin de raha r 22
Gas nikal kar dubra dalo sahi se vecum kar ke
Ap kaha se ho sir I'm very big fan ❤
Bhai ne bahut acchi jankari di hai
Thanks
30 mfd ki 36 mfd cepisetar lga sakte h kya
Amazing video sir ji ♥️♥️🌹
Thanks bro
Sir hamare ac ka compresar kutkut aawaj karata hai compresar chalu nahi hota garam hota hai holtege jadha leta hai muze bataye sir kya huwa
Compresar ka A.M.P chek kro agr zyada load le rha h to stater maaro agr phir bhi nhi hua to kharaab hai ...
Super demo sir ❤😅
Amper 12 so kar rha hee ranig presar 20 se upar nhe jata ded tan ac me kya falt ho sakta hee
O general split AC 2 ton
(Old model)
Countinue running not cutoff
Direct off in remote
How to solve the problem ji
Remaining
Room sensor nahi
coil sensor only
PCB relay change kariye
Autocut relay change Karo Bhai
Coil sensorbi check kardijiye
Very nice sir
Nice sir ❤
Sir ek kastomar nei bola ki ac 10 minutes Tak thanda kar Raha hai uska bad garam hawa felta hai Kia problem hai
Sir mai AC on krta hu 10 min cool krne ke baad cooling bnd ho jati hai kya problem ho sakti hai
बहुत achaa.
Sir windo ac me campresar start ho ne ke bad 4 ampr kuchh der bad 6 7 8 9 ampr ja ke campersar band ho jata
Bhai usme ya to capacitor kharab hai ya outer dusti hai
Thank you sir😊
Compressor din me sahi chalta h. Raat me start hokar band ho jata h. Power acha aata h rat me.
Bahut acha datawa
Sir ye bataiye ki out dor ke cundensor coil ko kaise change kare coper ka .
Thanks sir very nice video
Sar Mera Indore chalu hai lekin outdoor band hai Karan Nahin ja raha hai 410 Voltas AC inverter
Hello sir ek assamble ac ka video banaiye jese hum 410 gas ka outdoor 22 gas ke indoor me laga sakte he ki nahi
Gas se sirf compressor c Ka connection hota hai indoor Ka Nahi ,
Same milta julta indoor Laga sakte hain
1 ton ka ac ka outdoor 5 mint Chalke band ho ja rha hi fir 3 mint me start ho raha hi. Kya falt hoga
Compressor ka pumping kaise chaik kare kharab h ya thik agr discharge line p meetar lagayenge or fir aur FIR compresser on karte hain to meter ki sui uthne lagegi lekin usse to itna hi pata chalega ki han ye pressure nikal to raha hai discharge line se lekin pressure khinch raha hai section line se ya nahi ye kaise pata chalega
Uske liye aapko ac ke ampire cheak karna padega ac 2 ya 3 ampire lega aur discharge aur suction pressure same rahega
Shukrya bhai
Very beautiful
Thank you sir ji
Sir fully automatic washing machine k baren me bhi btynge
nice Sir
Very helpful video
बहुत खूब
Thanks
1.5 ton inverter ac 5 Star Lloyd 1 month new grill temp showing 13 all ok what is the problem
Shi baat h
Very nice
Voltas 1.5 ton inverter AC ki split global fan chalta hai uske bad band ho jata hai
Sar Meri AC Mein dikkat a rahi hai bulb band chalu band chalu ho raha hai competition Nahin uthata bulb Ban chalu Ban chalu hota hai kya dikkat hai light Sahi milane per To Nahin Hota Aisa
Sir cassette Ac indoor me supply aa rhi ha par indoor start nhi ho rha
Thankful video
Nice video sir
Ap kaha se ho sir ap se ac thik karwana hai
Nice guru 👍 ji
Nice video
Mera midea split inverter AC ko mcb switch-ON karne par indoor pe sirf display aata he fir 2-3 seconds me "53" /(S3),,Likha aata he, fir Display OFf ho jata he,,,But AC nahi chalta he,,,!! Remite ka button press karne se bhi kuchh nahi hota. ,👉Lekin,,"Manually ON" karne par AC chalta he,,! Pls tell what will be reason of this problem and suggest solution to solve it. Thanx
Apne ac ka connection dekha na, a to z, switch indoor oar out door connection dekha sokria.apkasath kisine dho tin mahina kam kare tou pora sik sakta hai, agar sikne walaka pas demag hu tou.
Bhaiya aapki ye video dekhe ya baki ki sab video dekhe sab pe to video bna di aapne kuch chord bhi do
Bai Acka compresermotor trip hoya ye ham kese janpayege or esku kese thik kertehe ak Videos danana
Capacitor change kar k dhk le ....or voltage b check kary ....gas kam ho tu pher b compressor heatup ho jata...ya pher blockeh ho phr b ....
Sir ji inverter ac ke outdoor ka fan kuch time chal kar band ho jata hai kya problem hai
Sir keval campresur direcot pawer dekar kitani der take Chala sakte hai...
2 - 5 minut Kyonki khali compressor heatup Bahut tej hota hai
Sir LG k ac hai 1.5 ton h
Section pipe thanda hai ice nhi h
Dischage pipe bhi normal hai
Amp bhi 9 le rha hai amp bhi thik aa rhi h filter bhi clean hai
Indore unit bhi clean hai
Magar room thanda nhi ho rha bas hawa aa rhi hai ac me kya problem ho skti hai
Plz reply
Ok details video deta hoon
Bhai outdoor ka fan speed thik hea dekho
Thanks sar
AC kaam Nahi kr raha Kya Kya check karein ,,,a to z plz make a video
मेरे पास एक टन एल जी का पुराना विंडो ऐसी है जिसमे रोटरी कंप्रेसर लगा हुआ है, इसे जब आन करते है तो ठंडा हवा देता है परन्तु ट्रिप होने के बाद ठंडा हवा देना बंद कर देता है बल्कि गरम हवा देना शुरू कर देता है। कृपया सुझाव दे इसे कैसे सही किया जा सकता है।
Hlo sir sharvo splite ac 1 ton ka compressor chalta hai fan vi chalta hai per outdoor se garam hawa nahi fekta hai or ampere 4 me 3.80 leta hai per suction pressure 20 leta hai or indoor thandi hawa nahi fektahai to aska kya problem hai sir coment me reply di jiega sir
Ac chok hai
Bht helpful vdo sir
Hamari ac bar bar on off hoti green light on off hoti he 2or 5 mint chalti he fir apne aap band ho jati he
Sir replai digiyega
Compressor continue chaalu hi rehta hai bandh nahi hota Aisa kyu...
Tk