@@RefrigerationfullSolutions bhai same yahi problem thi...m aur maine nitrogen se flash krke pura system indoor piping aur outdoor condenser coil full flash kiya tha.. fir new filter capillary laga ke vaccum krke gas charge kri.... Lekin wo fir bhi chillness ni aayi.... Ab mene customer ko compressor faulty bta diya hai...😮😮😮❤
Bhai Mari shtt bhi aisa hua par .. par gas local thi es lye ye problem a rahi thi phir humne vacuum kiya tha acche se gas fill kardi thi ac theek trha se work karne laga tha nitrogen camplsari hain kya bhai
गुरु जी मेरा 1.5 टन का mtubishi का split AC hai उसके outdoor ka top ka cover हटा देता हु उसका outdoor चलता है और जब लगा देता हु 3 से 4 मिनट चलता है और 5 से 7 मिनट के लिया बंद हो जाता है फिर चल जाता है।। कृपया हेल्प करे।।
Bhai pahle to knowledge lele R22 is a Pure refrigerants R22 can be added in liquid or vapor states. Or hameshaa yad rakho giyani baba vapor gas compressor ko hit karte hai liquid nai aur agli bar comment reply karne se pahle google karlena "aur wrong information derahe ho "ye bolne se pahle soch k bolo ok jise nai pata wo b pareshan huta hai @@sahebalam7744
Bhai sun pahle na tu knowledge lele giyani baba R22 is a Pure refrigerants R22 can be added in liquid or vapor states. Aur yad rakho giyani baba vapor gas compressor ko hit karti hai liquid gas nai "aur agli bar giyani baba bolne se pahle google karlena theek h aur "wrong information derahe ho Bina bat k mat bola Karo har kise k bech me ghosna achi bat nai hai warna" ungli nam pad Jay ga "😂 jok sapat @@sahebalam7744
Ek bar aur reply mat karna warna same reply kar kar k notification ki bharmar lagaunga. Banda video achi banata h Kai ladke new jo h seekhte h aur tum aaise comments karte hu
Very nice 👍 bhai shukriya
Bhaiya well and good service... and our teaching job...softly...
Bhai aap video bahut acchi tarika aur asaan tarika se batate hai bhai video dekha k bahut accha laga h bhai masha Allah ❤
Thanks bhai🥰
Ha bhai bahut hi achi video bani h bohot shi jan Kari mili hame 😊
@@RefrigerationfullSolutions bhai same yahi problem thi...m aur maine nitrogen se flash krke pura system indoor piping aur outdoor condenser coil full flash kiya tha.. fir new filter capillary laga ke vaccum krke gas charge kri.... Lekin wo fir bhi chillness ni aayi....
Ab mene customer ko compressor faulty bta diya hai...😮😮😮❤
Super video bro ❤❤
Bhai aapki video ki baat hi alag h
Right
Good working sir
Bahi compressor ko kabhi v alag karke flash krna chahiye
Nahi to sath me compressor ka oil nitrogen k sath nikalta hai
Very nice sir ji ❤❤❤❤❤
I'm from Myanmar bayi jaan apko lye doa🤲🤲🤲
Thanks bro 🥰🥰
Very nice 👍
Bhai nitrogen ki jaga kuch aur use kar sakte hea kya bhai utna bara selendar kha kha le jaunga bhai
Local gas charge kr rhy ho bro 😂😂
Composer se vecum kare to kitni der tak karni chahiye
Oil pipe me kaise chla jata hai?
Nytrojan gas bahot denger hoti h bhai apko warning deni chahiye
Bhai Mari shtt bhi aisa hua par .. par gas local thi es lye ye problem a rahi thi phir humne vacuum kiya tha acche se gas fill kardi thi ac theek trha se work karne laga tha nitrogen camplsari hain kya bhai
Kon sa gas kitna dalna he ye bata dijiye 600 number me kitna padta he
Aapne becume ko live nhi dhikhaya plz sir ek baar becume ki video or bnao
Bhaiya flashing karte time compressor on karega ya off
Compressor off rahega nahin to blast ho jaega flashing ka time
drier capillary kaun change karegaa.
Veri good
❤
Sir Ji a c raning main hai
Good
Dead nut se acha hoga
New Ac instal Kiya jata hai bhai to usko Ac ke likaiz kaise check Kiya jaata hai bhai
Pressure dalke ke bhai....or outdoor ka gas release kiye bina.....pure pipe se lekar indoor tak pressure daalo
Isme gas kon sa he
R22
❤❤❤❤❤❤❤❤
Tel kaha se aya
Bhai Mera samsung split AC 16 me jitna cooling hota hai 22 me bhi same cooling hota hai kya problem hai please batao mujhe
Coil sensor
Wrong pip ghalat falay gas ban kia discharge pipe ban nahi kia
Ac instal kar ke dikhao bhai aap bhai
Okay
गुरु जी मेरा 1.5 टन का mtubishi का split AC hai उसके outdoor ka top ka cover हटा देता हु उसका outdoor चलता है और जब लगा देता हु 3 से 4 मिनट चलता है और 5 से 7 मिनट के लिया बंद हो जाता है फिर चल जाता है।। कृपया हेल्प करे।।
Outdoor unit ki fan ki speed check karo thik h
@@RefrigerationfullSolutions चेक की वो ठीक है ac wala bol reha hai गैस कम है इसलिए हो रहा है
@@RefrigerationfullSolutions गैस भी डाल दी अब बोला है PCB me kuch फॉल्ट है।।
Compressor heat up to nhi hai.... Wo to dekh kr hee pata chal jayega.....
Ji aapki ac ka condenser fan week hai jisse heet na nikal pa rahi hai aur compresser trip ho raha hai
R22 kabhi v vapour me charge karo wrong information dete ho bhai😊
Bhai tujhe pata hai na to vapour me hi karna ok giyani baba
@@OgBOSSgaming553 kyu jal gyi kya sahi bola to tumhare knowledge ke liye bola
Bhai pahle to knowledge lele R22 is a Pure refrigerants R22 can be added in liquid or vapor states. Or hameshaa yad rakho giyani baba vapor gas compressor ko hit karte hai liquid nai aur agli bar comment reply karne se pahle google karlena "aur wrong information derahe ho "ye bolne se pahle soch k bolo ok jise nai pata wo b pareshan huta hai @@sahebalam7744
Bhai sun pahle na tu knowledge lele giyani baba R22 is a Pure refrigerants R22 can be added in liquid or vapor states. Aur yad rakho giyani baba vapor gas compressor ko hit karti hai liquid gas nai "aur agli bar giyani baba bolne se pahle google karlena theek h aur "wrong information derahe ho Bina bat k mat bola Karo har kise k bech me ghosna achi bat nai hai warna" ungli nam pad Jay ga "😂 jok sapat @@sahebalam7744
Ek bar aur reply mat karna warna same reply kar kar k notification ki bharmar lagaunga. Banda video achi banata h Kai ladke new jo h seekhte h aur tum aaise comments karte hu
Ac gatia chiz he,