How do you keep fert dust and innoculant build up in the center two manifold section when running a 6 run setup? The cap in the center is removable but the factory housing, where the plastic 2 inserts go have foam inserts in them
Removing them is the best thing to do if you can't solve the problem. we solve the problem and still get the functionality of them so now you get the best of both worlds!
I think the rubber wouldn't compress enough and fill the voids that exist well allowing it to be installed. There's so much variance between the tank plastic walls in this rigid steel that you need something to fill all the gaps. We have fought these things getting them installed the way it is with the foam seal. Good question though.
Very nice work gents! Love it. Going to be ordering soon!!
Excellent thanks for the feedback!
How do you keep fert dust and innoculant build up in the center two manifold section when running a 6 run setup? The cap in the center is removable but the factory housing, where the plastic 2 inserts go have foam inserts in them
Hi Lee, if you are running with a 6 run set up - we provide foam plugs to plug the extra runs. Give us a call at 701-205-1485 if you need them!
Should get rid of those troublesome half shut off like AirSeederParts meter box
Removing them is the best thing to do if you can't solve the problem. we solve the problem and still get the functionality of them so now you get the best of both worlds!
i was thinking the same thing. individual shut offs per primary allow you to run different hose configurations also
Good goin guys...Fargo Proud!
Thanks! It's been fun and humbling to have the opportunity
Saw you on the MF channel! Good work!
What is the weight difference?
I would guess its about the same. Both have about the same amount of metal in them ours is just the kind that doesn't corrode as fast.
I have Green,, but I'm confused isnt Red and Rust the same color???? lol
sometimes! they both followed ea other down this rust hole haha
What grade SST are you using and why not add a wash out port and a buna n gasket not foam
I think the rubber wouldn't compress enough and fill the voids that exist well allowing it to be installed. There's so much variance between the tank plastic walls in this rigid steel that you need something to fill all the gaps. We have fought these things getting them installed the way it is with the foam seal. Good question though.
good job guys! i am from ukraine and i will buy this item, what is it price?
For Ukraine please reach out to Agrokar ;)
Depressurized. Much better than the original