Yalang YL620/YL620-A VFD Instructions

Поделиться
HTML-код
  • Опубликовано: 4 дек 2024

Комментарии • 56

  • @sawozny
    @sawozny 3 года назад +4

    I see you set several parameters that I can't find very detailed explanations for. Is there a detailed parameter guide, anywhere? For example, what's the difference between Highest Output Frequency and Maximum Voltage Output Frequency (P00.04 and 05)? What do the Middle Frequency and Middle Voltage parameters (P00.07 and 08) do? What do the VF Curve setting options (P00.12) 0 through 4 represent? It seems like a solid product, but the documentation is a little sparse in areas that seem kind of important. Any ideas where I could look for more details?

  • @PatrickKrolickoff
    @PatrickKrolickoff 2 года назад

    Thank you for the video. WHAT'S a difference 620 and 620-A models? I guess A is newer. And ...?

  • @ZOIMIBiIE
    @ZOIMIBiIE 3 года назад

    How do you perform a factory reset?

  • @GraphicManInnovations
    @GraphicManInnovations 3 года назад

    this series have a rs485 connection or not??

  • @xavierlopezsanz2429
    @xavierlopezsanz2429 3 года назад

    Hi, your vfd YL620 works very well for me.The machine has withstood a water leak in the pipes of my house very well. I use mach3 and I can control on/off with the program, but I'd like controlling speed with the lines of my g-code/m-code. Can you give me any orientations about the parameter I have to change? I have a manual from you but amb not sure if I understand right how to do it? Thank you in advance.

  • @lorenzomanuli1282
    @lorenzomanuli1282 2 года назад

    Hello what are the settings for the maximum power. I have an engine from a car lift and it doesn't have enough power

  • @cncsandingtools
    @cncsandingtools 4 года назад +1

    Hi do you have a wiring diagram that shows connections to be run from a external 0-10 volt signal? I would like to operate turn on and off and set speed from my cnc control, Thanks

    • @GraphicManInnovations
      @GraphicManInnovations 2 года назад

      i am stuck there now, fw/rev no prob, but i cant pwm it via mach3, got a way?

  • @yettimusafri4410
    @yettimusafri4410 3 года назад

    hi! thank you for the video it help so much! any I have a problem with the inverter I need your help. The spindle is suddenly stops running and the VFD shows Error 4. I already watch some tutorial and i set up again by doing factory reset. The error 4 disappeared but when i try to rotate the panel potentiometer the frequency shows 10Hz the spindle is not move, until i set 47 Hz the spindle is move. But the rotation is different, it is less noisy but i feel there is something wrong. Do you have any idea? thank you

  • @teachermaqui2763
    @teachermaqui2763 4 года назад +1

    Does anyone know where can I get the manual of a YL620-A in spanish? I really need it.

  • @robertomuhammad35
    @robertomuhammad35 2 года назад

    Hi . Whats reason of error 0005 and error 0007

  • @cristhianodamata
    @cristhianodamata 5 лет назад

    ayuda... yo tengo un VFD YL620-A.. un spindle de 2.2Kw ambos para 220v...Yo estoy en Mexico. el voltaje es de 220V, el problema es que el spindle se calienta muy rapido. Quiero saber como configurarlo... Los parametros que pones, los tienes en 50hz yo en 400hz... esta bien?? o como debo de configurarlo?

    • @ИгорьАрутюнов-м5т
      @ИгорьАрутюнов-м5т 4 года назад +1

      Estimado que descubrió la configuración del inversor?

    • @cristhianodamata
      @cristhianodamata 4 года назад

      @@ИгорьАрутюнов-м5т que tal, gracias por contestar. Aun no logro hacer que no se caliente.

    • @cristhianodamata
      @cristhianodamata 4 года назад

      me enviaron la siguiente configuracion...
      Code Function
      Set Range&
      Function
      Explanation
      Factory
      Setting
      P00.00 Main Frequency 0-120HZ(400HZ) 400HZ
      P00.01
      Source of Run
      Control mode
      0: .Operator board
      0
      1:.External terminal
      P00.03 Stopping Mode
      0:Decelerating stop
      1:Coasting stop 0
      2:DC brake stop
      P01.00 REV Run Setting
      0:Rev Run Enable
      0
      1:Rev Run forbidden
      P03.09
      Upper limit of panel potentiometer
      frequency
      0-120HZ(400HZ) 400HZ

    • @cristhianodamata
      @cristhianodamata 4 года назад

      P03.11 Upper limit of 1 AD value for analog input 0-1023 1010
      P03.13 Upper limit of the analog input 1 0-120HZ(400HZ) 400HZ
      P07.08 Frequency source selection 1 0: Operator board
      1: Pre~set Frequency,
      P00.00
      3: Analog Input.
      0
      P07.09 Frequency source selection 2 2
      P07.10 Frequency source selection 3 2
      P07.11 Frequency source selection 4 2
      P07.12 Frequency source selection 5 2
      P07.13 Frequency source selection 6 2
      P07.14 Frequency source selection 7 2
      Note:three
      control
      methods
      (P07.08)
      1.The motor speed is controlled by the operating panel
      2.Motor speed control by external terminals (Potentiometer 10K).
      P00.01 set to 1, P07.08 set to 3
      3.Motor speed control by external terminals. P00.01 set to 1,P07.08
      set to 1.

    • @ИгорьАрутюнов-м5т
      @ИгорьАрутюнов-м5т 4 года назад

      @@cristhianodamata ¿Cuál es su correo? Puedo enviarle la configuración que me envió el vendedor de mi kit (que aún no ha llegado pero estoy preocupado por la configuración del inversor))

  • @lorenzomanuli1282
    @lorenzomanuli1282 2 года назад

    Hi, I connected the VFD YL 620 A to 220V line monophase the motor turns but has no lifting power.

  • @skendermeta9137
    @skendermeta9137 9 месяцев назад

    Hello
    Where to connrct stop buton

  • @shakilshaikh8047
    @shakilshaikh8047 4 года назад +1

    How to display RPM instead of Frequency on this vfd

    • @jackzhou1683
      @jackzhou1683  4 года назад

      You can contact me by email at 402241468@qq.com

    • @mikeoldani7252
      @mikeoldani7252 3 года назад

      Did you ever figure this out? Im in the same boat....

  • @dronesvisionsaeriennes
    @dronesvisionsaeriennes 2 года назад

    Hello, I have a YL 620 A and I still can't get the spindle to start automatically by the GCode of my machining program.. (M3 start/M5 stop)
    P00.01=1 and P00.16=2
    Could you give me the solution..
    When I keep P00.01=0 and P00.16=0 everything works in manual correctly
    thank you
    Philip

  • @Pendawa_Diesel_Plus
    @Pendawa_Diesel_Plus 3 года назад

    I have buy yalang yl600 but always error 04! what the problem? how to detail setting the yl 600 parameter?

    • @TheCNCDen
      @TheCNCDen 2 года назад

      did you find out the problem and solution?

  • @rmzshka1740
    @rmzshka1740 4 года назад

    When the frequency Converter YL600-2.2 KW-220V is plugged in 220V, the fan turns on. And the fan does not turn off at all (even more than a minute - does not turn off). You can only turn off the fan by pressing the stop button. Is there any way to configure it so that fan doesn't turn on when plugged in 220V, or at least turns off a minute after it's turned on?

    • @jackzhou1683
      @jackzhou1683  4 года назад +2

      You can set the fan operation mode by setting parameters P12.11 and P12.12

  • @sonvo9151
    @sonvo9151 4 года назад

    Can you tell me about RS485 communication in this product?

  • @GAUCHITO
    @GAUCHITO 2 года назад

    i need install in one cnc control ,M3 M4 gnd and 10 v , Yuhai 990 M IS THE Control and can t work ,analog speed 0 10 v,
    would you help me ,Invt use s1,s2, GND A01 AND 24 V AND WORK OK, We bougth 20 set YL620 and need the connection

  • @victornguyen5649
    @victornguyen5649 4 года назад

    I have a YL620A. If the input voltage is 110V, what is the value of p005 and P006?

    • @jackzhou1683
      @jackzhou1683  4 года назад

      First of all, you have to determine whether the VFD you purchased is 110V or 220V, please contact me by email

  • @Bignac
    @Bignac 4 года назад

    Hello!
    I have a 3 kw inverter but the motor is only 2.2 kw.
    Where can I set the inverter to 2.2 kw? Where to enter

    • @jackzhou1683
      @jackzhou1683  4 года назад

      The output power does not need to be set, it is automatically adaptive according to the input voltage and current of the motor

    • @Bignac
      @Bignac 4 года назад

      0.3 kW. do 2.2 kW motors have the same settings?
      Is the engine not burning?
      Thanks for the reply!!!

    • @jackzhou1683
      @jackzhou1683  4 года назад +1

      @@Bignac As long as the frequency of the motor is the same as the set frequency of the VFD, the motor will not be burned out

    • @Bignac
      @Bignac 4 года назад

      @@jackzhou1683 I see, thank you!

  • @barskulahsz3154
    @barskulahsz3154 Год назад

    I have a yo 620-A and when I start the spindle by operation panel, the spindle runs but i cannot stop or adjust ist anymore. All lights on operation Panel blink in this situation. Does anyone have a Solution

  • @Math_cornery
    @Math_cornery 4 года назад

    I have inverter yl620g , but when im opration for my machine with 5,5 kw capacity . Myachine cant move. What the problem ? My inverter not powerfull i think .may my inverter have a mistake program
    Please help me give ure solution thanks

  • @DMilkyWay
    @DMilkyWay 5 лет назад +2

    if my input voltage is 220v then p0005 is set at 400 hz,and the p0006 should be set at 50%?

  • @woodywoods5373
    @woodywoods5373 2 года назад

    My yl600 runs fine for about 45 minutes the freezes with the lights flashing and can't turn off by using the control very dangerous

  • @justinvickers1029
    @justinvickers1029 4 года назад

    Hello can you help setup please

  • @3diablo3
    @3diablo3 4 года назад

    Hello, is the YL620A model suitable for INPUT 220 single phase and OUTPUT 380 three phase? I see that the input connections are 3, RST. There is something wrong?

    • @jackzhou1683
      @jackzhou1683  4 года назад

      NO, this VFD is a single-phase 220V input, three-phase 220V output, suitable for 220V motor

  • @tubin341
    @tubin341 3 года назад

    This VFD is junk. Used 6 times and the board blew

  • @stephenhawker9424
    @stephenhawker9424 4 года назад +1

    Can you tell me about RS485 communication in this product?