STEP-BY-STEP Installation of 12KW Deye Solar Hybrid Inverter with Lithium Battery (Start to Finish)

Поделиться
HTML-код
  • Опубликовано: 2 фев 2025

Комментарии • 63

  • @SimonMazinge
    @SimonMazinge 11 дней назад +1

    Great 'LIVE' video shot on a neat Smart Solar installation. Evidence that SMART SOLAR is all about in-depth knowledge & intrinsic know-how what to do when it comes to install professionally. Top notch!

  • @nzubegoodluck9056
    @nzubegoodluck9056 13 дней назад +1

    Good job 👍

  • @hekamteam
    @hekamteam 9 дней назад +2

    battery cables in my country needs to be 50mm2 for dc 12kw great work

    • @zurriannetworks
      @zurriannetworks  9 дней назад +2

      Thanks
      The battery cable here was 100mm2(50mm2 x2 battery inputs.
      Thanks for the feedback

  • @greatn2213
    @greatn2213 11 дней назад +1

    Very neat installation man!

  • @benedictokpala2110
    @benedictokpala2110 17 часов назад +1

    Great work you are doing.
    Where do you get your DEYE products?

  • @celestinaosokoya5676
    @celestinaosokoya5676 12 дней назад +1

    Great job 💯

  • @anietienssien6643
    @anietienssien6643 12 дней назад +1

    The use of ferrules or terminal blocks would be best in wire connections and cable terminations to avoid arcing.

  • @JerrySikazwe
    @JerrySikazwe 7 дней назад

    Thanks

  • @theguy4355
    @theguy4355 4 дня назад +1

    Am i right by saying this is a 12kva single phase inverter and not a 3 phase inverter ? I see has 3 load outputs so its seem to be 3phase but his only using 0ne phase

  • @smallqwaro
    @smallqwaro 12 дней назад +1

    Do you mind explaining why the inverter wouldn't allow the 300 you wanted and didn't you check the specs and calculate everything before the job?
    Also is the avr single or three phase?

    • @zurriannetworks
      @zurriannetworks  11 дней назад +1

      The AVR is 3phase
      The max charging and discharging current for Deye 12KW is below 300A (around 290A there about)

  • @donlatinohits
    @donlatinohits 12 дней назад

    is the grid the input in the AVR ?

  • @omarutariq9501
    @omarutariq9501 5 дней назад

    Can you please share the version of Deye Inverter? Also is it Single Phase or Three Phase?

    • @theguy4355
      @theguy4355 4 дня назад

      Same question i asked if its single phase or 3 phase. Because im searching to see if the Deye 12kva are also in single phase but only 3 phase comes up.

  • @adisaazeez5149
    @adisaazeez5149 12 дней назад +1

    I am just curious! Will that building besides where the pv modules are being mounted not cast Shadow on them, hence reducing their optimal performance.

  • @KossyUgwa
    @KossyUgwa 13 дней назад +1

    💯💯

  • @ernestsuper
    @ernestsuper 12 дней назад +1

    I was wondering Why use 580w panels when there is 750w panels, won't you be using less of those and having more space to work with?

    • @zurriannetworks
      @zurriannetworks  11 дней назад +2

      580W was the biggest size available at the period of the project

  • @StepDoku
    @StepDoku 13 дней назад +1

    so you allow the batteries to be charged by the grid, what happens when the sun comes up? I thought you will just let the grid pass through without charging the batteries so the sun will do that in the morning or when the weather becomes OK for that? just wondering...

    • @zurriannetworks
      @zurriannetworks  13 дней назад +1

      So Deye does the charging priority automatically (based on your settings). In this particular site, I set the system never to use Grid for both charging & passing through from 6:00 to 21:00.
      You can alter these settings at will.

    • @StepDoku
      @StepDoku 13 дней назад +1

      @ I get it now
      In one of your settings shot I saw grid charging so I thought you left it at that…great work buddy

  • @oge3680
    @oge3680 12 дней назад +1

    This is a good job. What could be the cost of this 12kw with 30kva lithium battery, please?

  • @titoraddingi5444
    @titoraddingi5444 11 дней назад

    What’s a roughly budget for the equivalent .

  • @ayodeleojetunde6183
    @ayodeleojetunde6183 13 дней назад

    Please can you send me a link of where you get your enclosure boxes! By the way nice and neat job

    • @zurriannetworks
      @zurriannetworks  13 дней назад

      I do sell enclosure boxes, kindly inbox

    • @OmtechSolar
      @OmtechSolar 10 дней назад

      Pls are u in lagos i will to get this enclosure box for a project pls ur line..​@@zurriannetworks

  • @MaigidaUuuCharlesPaul-c5d
    @MaigidaUuuCharlesPaul-c5d День назад +1

    Are you accepting apprentice

  • @Resonance-n4h
    @Resonance-n4h 10 дней назад

    Hi, please kindly check your Inverter manual and confirm how you installed the white magnetic beads. The bead is to be installed on the either the live or the neutral lines. the way you connected it now is leading to the cancellations of magnetic field. Please kindly correct it when you visit next time.

    • @zurriannetworks
      @zurriannetworks  9 дней назад +1

      I appreciate your feedback.
      But for Deye, that is the proper way to connect the magnetic ring (the way we used it in the video, pass both wires through it).
      Manual link below!
      chrome-extension://efaidnbmnnnibpcajpcglclefindmkaj/www.deyeinverter.com/deyeinverter/2024/08/13/rand/4249/instructions_sun-12-16k-sg01lp1-eu_240813_en1.pdf

    • @Resonance-n4h
      @Resonance-n4h 9 дней назад

      @@zurriannetworks Alright Bros, I do appreciate your feedback. Very neat installation by the way

    • @Resonance-n4h
      @Resonance-n4h 9 дней назад

      Yes, I confirm your magnetic beads installation ok from your attached manual. I never see this bead arrangements in some of the Deye Inverter I've done.
      I just concluded 80KW Deye Inverter installation (with 4 units of 16KW) and never see that. Thanks for sharing.

    • @zurriannetworks
      @zurriannetworks  9 дней назад

      I see, 16kw doesn’t come with any of the rings.
      It’s peculiar to their 8kw & 12kw.
      One love brother!

  • @vicono9998
    @vicono9998 8 дней назад

    Hi, I like the work you guys have done. what is the input voltage to the mppt (inverter) from the solar system? Is your client house running a 3 phase setup or single?

    • @zurriannetworks
      @zurriannetworks  7 дней назад

      It’s a single phase setup.
      Input Voltage is 120 - 500V

    • @vicono9998
      @vicono9998 5 дней назад

      Ok. How many rooms does the property have as I am interested in the setup however wondering if having 30kw is an over kill, only if it less than 6 rooms

  • @EI.01
    @EI.01 11 дней назад

    Where is your location in Nigeria

  • @kolobagale3779
    @kolobagale3779 10 дней назад

    I find your wires size smaller than required....

    • @gagzman1
      @gagzman1 10 дней назад

      My thoughts exactly

  • @БагиТнс
    @БагиТнс 6 дней назад

    Ты похож на 50-cent

  • @ovieoyegwa6153
    @ovieoyegwa6153 6 дней назад +1

    The panels location is heavily shaded.
    No battery protection.
    Cables not correctly sized(fire hazard)

    • @theguy4355
      @theguy4355 4 дня назад

      I also noticed he has no protection between Inverter and batteries

    • @Collinsbond1
      @Collinsbond1 День назад +1

      Deye batteries have internal protections. My thought

    • @zurriannetworks
      @zurriannetworks  22 часа назад

      you are correct

    • @zurriannetworks
      @zurriannetworks  22 часа назад

      Deye inverters come with in-bulit DC breakers (in this case, two battery inputs with a 200A breaker each).
      Also, each of the Deye batteries in use comes with a 125A MCB breaker.

  • @geraldmano
    @geraldmano 12 дней назад +3

    Didn't explain anything shaaaa

  • @bobbypeters-g6d
    @bobbypeters-g6d 16 часов назад +1

    I need the 12kw inverter.. kindly contact me soonest..

    • @zurriannetworks
      @zurriannetworks  15 часов назад

      Inbox our Instagram, @zurriannetworks
      Or email us, zurriannetworks@gmail.com