Introduction to the

Поделиться
HTML-код
  • Опубликовано: 26 авг 2024
  • A Short introduction to the Sunsynk low-voltage hybrid inverter, major benefit to using a low voltage inverter rather than a high-voltage three-phase is it's much safer on the battery connection no high voltage DC connections

Комментарии • 26

  • @TheChattingh
    @TheChattingh 2 года назад +1

    My 12kw 3ph unit will be installed next week, here in Johannesburg , can't wait!

  • @ronnywalia7804
    @ronnywalia7804 Месяц назад

    I have a 12kva 3phase sunsynk hybrid inverter, with 3 ×5.kw batteries from freedom won, the problem I have is when I want my generator to top up it is very slow to charge ot at night,I have a kipor 3pase kde20ss3. Please advise

  • @cvanson002
    @cvanson002 3 года назад

    Looks great and glad it is available in South Africa. Keith you mentioned it has a max PV input of 1000V DC but the versions I could find in South Africa have an 800V DC max. When and where will the 12kw 3 phase Sunsynk hybrid inverter that can handle the 1000V DC be available from in South Africa?

  • @moisescohen4020
    @moisescohen4020 2 года назад +1

    please I have a problem F33 is in inverter hibdio 8kw trifasico

  • @shaheenganiyt
    @shaheenganiyt 2 года назад +1

    Thanks for the informative videos.
    Is the Sunsynk three phase hybrid inverter output 12kW per phase

  • @WinstonSmith64
    @WinstonSmith64 2 года назад +2

    Hello Keith. Great channel. A few questions. We have a 14kWp system that was formerly grid tied. We are thinking of replacing the old inverter on this plant which has 50 x 285W Poly Large Wafer JA panels - with the Sunsynk 3 phase 12kW hybrid inverter, because we are adding 3x5kW PylonTech battery storage. How do you pair the SunSYnk with a suitable panel as you commented in the video? Also does this inverter ship with CT's and Energy Meter or only CT's with the metering aspect embedded? Best wishes - Winston Smith - Johannesburg South AFrica

    • @mrutubeuk
      @mrutubeuk Год назад

      Any response to this excellent question?

  • @MatthewOgd
    @MatthewOgd 2 года назад +1

    What happens when a single phase is of grid is offline/outage. Will you draw from the other two phases and still charge DC side? Will UPS side of inverter then keep pulling from DC for all 3 phases? Or will passthrough work for 2 of them, and third will be at off grid limit ? What about grid tie feedback when one phase is down? Will there other two still still allow export?
    Think home or office environment, not 3 phase motor world.

    • @bootangy
      @bootangy Год назад

      did you find out?

  • @henrymeier3224
    @henrymeier3224 2 года назад

    Afternoon Keith
    Hope you are well… may you have a prosperous 2022…
    I have a question I hope you can assist me with…
    Do you need a set of batteries for each phase or will a single battery set supply DC power to all three phases in case of a power failure for example?

  • @mondotv4216
    @mondotv4216 Год назад

    Is this a grid forming inverter in the event of grid down situation? ie could it keep another 3 phase inverter running?

  • @bassplaya69er
    @bassplaya69er Год назад

    how many can be paralelled? the manual states 10 in one place and 4 in another. The OEM manufacturer, deye states 10.....

  • @jodianne4428
    @jodianne4428 Год назад

    Hi Keith, I just installed this inverter, is it supposed to make a this white fan noise often, particularly in the day?

  • @jakeslouw3416
    @jakeslouw3416 3 года назад

    A link to a product sheet would be nice.........

  • @leighhorton2806
    @leighhorton2806 3 года назад

    Good intro keith

  • @zoegamba7203
    @zoegamba7203 Год назад

    Hi Keith, have an error 56 fault on my 12kw 3phase inverter, can you please assist

  • @oelofbergh9042
    @oelofbergh9042 2 года назад

    Hi Keith, need help, i had a 12kw 3phase sunsynk instaled, it only give 217 volt at inverter per phase, is there a way to push it up to 230v, help please.
    The system is grid tied at the moment with panels and battery bank

  • @wimpiestruwig1368
    @wimpiestruwig1368 2 года назад

    Do you have a training video on the 12kw 3ph units

  • @bootangy
    @bootangy Год назад

    would maxeon 5 with enphase microinverters work with this 3 phase?

  • @kiello26
    @kiello26 2 года назад +1

    Hi, does sunsynk have a 3 phase delta inverter? Thanks

    • @sunsynk
      @sunsynk  6 месяцев назад

      Yes just a software up date

  • @mrniceguy5731
    @mrniceguy5731 Год назад

    i need 20kw 3 phase

  • @fattyco1
    @fattyco1 Год назад +5

    Just a heads-up for anybody trying to gain some insight into this particular product. The statement by Keith that this inverter can supply 6Kw per phase off-grid, and up to 12Kw per phase grid-tied, is complete and utter nonsense. This has been confirmed with Sunsynk tech support. The unit can only supply 12Kw in total but CAN supply 6Kw on one phase, 4Kw on another, and 2Kw on the third phase - a TOTAL of 12Kw. The rest of the video may be accurate, but that particular statement is truly a load of BS and should be removed from the video as it is completely misleading, and subsequently casts doubt on everything else said - whether valid or not. That's not good.

    • @derickkruger5680
      @derickkruger5680 7 месяцев назад

      Thanks bud, i could smell that rat BS he was uttering a mile away. Immagine pulling 36kw from the 12kw inverter 😂😂

    • @sunsynk
      @sunsynk  6 месяцев назад +1

      hi, interesting comment, the Inverter is actually asymmetrical loading and could have 100% asymmetrical on grid and 50% of grid