Wind Loading on Tower with Dead and Live Load(Staad Model)

Поделиться
HTML-код
  • Опубликовано: 9 янв 2025

Комментарии • 107

  • @ttsr7387
    @ttsr7387 4 месяца назад +2

    What a way of teaching!!!! very well explained. Thank you sir 🙏

  • @sivaraajvardhinedi8916
    @sivaraajvardhinedi8916 2 месяца назад +1

    Sir thankful u, explained with simple language step by step

  • @emotionreloaded2016
    @emotionreloaded2016 Месяц назад +1

    Thanks a lot sir!! Please continue more STAAD series

  • @kailashbhore5785
    @kailashbhore5785 3 года назад +1

    Very informative video. Thanks for making this video. Content is so good. Thanks , please make such good videos. Thank you

  • @murali1802
    @murali1802 3 года назад +3

    Amazing patient demonstration. Crystal Clear explanations. Well organised presentation. A lot of effort must have surely gone into this.

    • @eCivilTech
      @eCivilTech  3 года назад +1

      I do job in design field. And job in design field is very loaded, we get less extra time. It took me 4-5 months to create this video.
      Guys like u are the motivation 💪 behind it. Thanks for your comments. Will always try to deliver best. 😊

  • @sreekanthk7602
    @sreekanthk7602 5 лет назад +2

    very good lecture on steei strcture thank you

  • @attaullahshaikh5825
    @attaullahshaikh5825 4 года назад +2

    thank you so much sir your videos helped me a lot for my project and the comment section cleared almost all my doubts you are doing a great job keep it up sir

  • @javediqbaljibs3524
    @javediqbaljibs3524 6 лет назад +3

    VERY NICE, given full detail on calculations. Good Job. Excellent Work Done.

  • @dayanandan8045
    @dayanandan8045 4 года назад +1

    Very well explained... thank you

  • @swapnilbirajdar6647
    @swapnilbirajdar6647 Год назад +1

    Firstly thank you for the great explanation of TLVA ,can you suggest video for BFS Site explanation(LOAD CASE'S for three leg n 4 legs tower)

  • @vadatusanskritam
    @vadatusanskritam 3 года назад

    Very informative and nice video.. i appreciate your efforts....thanks once again...

  • @eswarallu1145
    @eswarallu1145 6 лет назад +2

    EXCELLENT WORK SIR THANK YOU

  • @mukeshkummarrana6818
    @mukeshkummarrana6818 3 года назад

    quite useful video

  • @ankitkaushal1592
    @ankitkaushal1592 4 года назад +1

    Sir, you are life saver

    • @eCivilTech
      @eCivilTech  4 года назад +1

      Thanks for your appreciation 😊

  • @limamanohar4484
    @limamanohar4484 2 года назад

    very usefull.. if consider Seismic load also it would be helpful

  • @besmellehfayzy6692
    @besmellehfayzy6692 5 лет назад +1

    thanks alot sir for this video .

  • @aashishp007
    @aashishp007 4 года назад +1

    Good job👍
    Just few questions
    1. How about shielding factor for multiple frames spaced one behind other
    2. Gust factor consideration

    • @eCivilTech
      @eCivilTech  4 года назад +1

      Thank you very much.
      1. As per my knowledge, In code tables are given for square and triangular tower. So no need to go for shielding effect as cf is considered including back frame. And if you are going any frame like for water tank or ano other than u can use shielding effect based on distance between frames.
      2. You can use gust factor and must be used for high towers. We use in transmission towers.
      Your views are most welcome

    • @aashishp007
      @aashishp007 4 года назад

      @@eCivilTech thanks for your response 👍

  • @MabastBechar
    @MabastBechar 6 лет назад +1

    WAITING FOR NEXT VIDEO. THANK YOU SO MUCH

    • @eCivilTech
      @eCivilTech  6 лет назад

      I'm glad that you people are showing such patience ... I'm working on the same and promise to come with effective video. Please give me some more time. thanks for watching and being a part of eciviltech.

    • @MabastBechar
      @MabastBechar 6 лет назад +1

      eCivil-Tech. Dear sir, I have some questions and could not find right answer online.
      1. Why did you release the moment at pins at a time the pin does not transfer any moment?
      2. What is the difference between having 5 m2 EPAa at only one face or 5 m2 at each face (20 m2 in total)? I mean besides its dead load, does it make any change in wind load calculation?
      3. If the azimuth of antenna is not parallel with wind direction, should I use EPAa = EPAnsin2theta + EPAtcos2theta?
      4 when we say a wind puts load on a face, it also puts some load at the face behind too, should I consider that in calculation?
      Thank you so much

    • @eCivilTech
      @eCivilTech  6 лет назад +2

      Dear Mabast,
      1. If we don't release the bracing at it's end, it will start taking moment then it will try to act as a main member. It might be possible in some cases where it will attract more moment than your main member. consequently bracing members will come very heavy and uneconomical. To avoid such things we release at it's ends or you can choose truss specification in Staad.
      Here in our model Pipe leg section is main member which should take more axial force and moment. Bracing will prevent the main section from buckling.. (By providing bracings we are actually reducing effective length of column, just like trusses. Bracing will take only axial load i.e. compression or tension only).
      2. EPA stands for effective projected area. Consider if you're taking about about a GSM antena with EPA 5 sqm, that means while calculating wind load you've to consider exposed area to wind = 5 sqm only not 20sqm.
      3. For GSM antina no need to go for any complicated formula . You can consider the cases what I've considered in this video which is sufficient. But for Microwave antenna follow tables C1,C2,C3 and C4 as per ANSI-TIA-222G. I'm suggesting to follow the tables as in some cases microwave antenna are very large as 2.8m or 4.2 dia etc.
      4. There will be two forces one will be on windward (Pushing) and other will be on leeward (drag force). But if you're calculating load from IS 875 part 3, then you've to apply from front only. As Cf contains both the effects.
      I hope this will be helpful to you.
      If you like the video then pls hit the like button and share with your friends.
      Regards

    • @MabastBechar
      @MabastBechar 6 лет назад

      Dear sir,
      thank you for your reply, it is very helpful. I could check a rooftop tower with your notes. I have another issue with its foundation. how can i design a rooftop tower foundation with staad pro?

    • @Shib.Sankar
      @Shib.Sankar 4 года назад

      @@MabastBechar 👍

  • @sunithaan4920
    @sunithaan4920 5 лет назад +1

    Thank you so much sir for video...can you please share PEB design also

    • @eCivilTech
      @eCivilTech  5 лет назад

      Most welcome. I will do videos on PEB. But after completing this tower. So it will take time. But now as subscribers are increasing day by day, I'll give more time to eCiviltech and try to deliver more videos.
      Also thanks for being part of eCiviltech. 😊

  • @prasannapandit8091
    @prasannapandit8091 3 года назад

    Is there any dynamic effect due to wind load as per clause 9.1 IS 875 part 3 (2015). Can you give example how we can provide dynamic effect of wind load on chimmney?

  • @anshupal8965
    @anshupal8965 6 лет назад +1

    Can you please do the analysis and design of transmission tower

  • @raedqwareq6901
    @raedqwareq6901 4 года назад +2

    Hello Sir,
    Many thanks for your great work and efforts.
    just i would like to ask you if you have any videos according to American codes like ASCE07
    Regards

    • @eCivilTech
      @eCivilTech  4 года назад +1

      Right now I've not done any video on ASCE. Thanks you.

    • @raedqwareq6901
      @raedqwareq6901 4 года назад

      @@eCivilTech Many thanks sir

    • @raedqwareq6901
      @raedqwareq6901 4 года назад

      do you have any idea about how can i calculate the F value & Cf on MW link, and which table can i use according to ASCE. thx

    • @eCivilTech
      @eCivilTech  4 года назад

      I am not very familiar with ASCE 07 . But if specs required american code, I think you can go with ANSI/TIA 222-G. Here you get everything for antenna tower and mono-pole.

  • @siddheshdeorukhkar667
    @siddheshdeorukhkar667 4 года назад +2

    Hello Sir
    Excellent Video!
    could you please tell me where we got the material properties?
    ISOTROPIC STEEL
    E 2.05e+008
    POISSON 0.3
    DENSITY 76.8195
    ALPHA 1.2e-005
    DAMP 0.03
    TYPE STEEL
    STRENGTH FY 2

    • @eCivilTech
      @eCivilTech  4 года назад +1

      Hi siddhesh,
      If you are using staad connect series, you can see material menu just above working window. Click on that menu, a window called "material whole structure" will pop-up at right bottom corner. You can put all properties in that window.
      For material properties refer IS 800:2007 clause no. 2.2.4.1 page no. 12.

  • @waqasaslam7727
    @waqasaslam7727 7 лет назад +1

    please upload next videos for design of members thanks

    • @eCivilTech
      @eCivilTech  7 лет назад

      Hi Shahnawaz, I'm working on the same but need some more days.. will upload in few days.

  • @civilcivil2885
    @civilcivil2885 7 лет назад +1

    sir ap double girder crane pr video bna sakte ho kya

    • @eCivilTech
      @eCivilTech  7 лет назад

      Right now i'm working on two videos. My next video will be on Engineering mechanics which will be uploaded in November and after that design of telecommunication tower i.e. 4th video of series. In future I'll surely make some videos on crane girder design. By the way if you want to do it by your self, you can refer book "Limit states design of steel structures" by S.K. Duggal

  • @ersatishvishwakarma5229
    @ersatishvishwakarma5229 3 года назад

    Sir ek food over bridge ka design kr

  • @chackochiramal8610
    @chackochiramal8610 3 года назад

    While applying the uniform wind force on the tower (angles and circular section); why did you take the area of the circular section as diameter and the area of angles as width?.

  • @shubhamwadhwa2867
    @shubhamwadhwa2867 5 лет назад +1

    Can you please attach the ppt that you are using , it will be really helpful

    • @eCivilTech
      @eCivilTech  5 лет назад

      Sorry, it cannnot be shared.

  • @attaullahshaikh5825
    @attaullahshaikh5825 4 года назад

    Hello sir you are saying that allowable deflection is according to the clients requirement but how much degree the deflection can be taken? And which code says about this please tell me

  • @mkmuhsin
    @mkmuhsin 4 года назад +1

    wind load applied at one face only
    other face is ignored. is this code provision by taking full shielding effect?

    • @eCivilTech
      @eCivilTech  4 года назад +1

      Hi Mushin, Other face is not ignored it is covered in calculated cf. I have applied all the loads on front face only. You can also do half of total force and apply on both faces.

  • @civilcivil2885
    @civilcivil2885 7 лет назад +1

    thnx bro

  • @sahilfaras6187
    @sahilfaras6187 4 года назад +1

    Hello sir, can you please tell me the allowable deflection in members?

    • @eCivilTech
      @eCivilTech  4 года назад +1

      Deflection is serviceability criteria. It totally depends on clients requirements and type of structure. For telecom tower client himself will give you his deflection criteria as per equipment which they are going to install on that tower. Generally they ask for 1 degree to 2 degree angle from vertical.

    • @sahilfaras6187
      @sahilfaras6187 4 года назад

      @@eCivilTech Thank you so much sir

    • @sahilfaras6187
      @sahilfaras6187 4 года назад

      @@eCivilTech Sir can you tell me the allowable shear stress in members please? How to calculate allowable strear stress in members?

  • @praveenpatangevlogs1634
    @praveenpatangevlogs1634 3 года назад +1

    Need cage ladder design video

    • @eCivilTech
      @eCivilTech  3 года назад +1

      For which structure you want to design cage ladder.
      Generally we dont design ladder as it is not primary or main structure. Ususally we give L50x50x4 angle section for ladder sides and 16 dia bar for steps. Use 40x4 thick plates for cage.
      For which structure you want to design ladder?

    • @praveenpatangevlogs1634
      @praveenpatangevlogs1634 3 года назад

      For the WTP STRUCTURE access slab

  • @ritikabohra829
    @ritikabohra829 5 лет назад +1

    Hi can you please tell me why you have not applied wind load in the leeward side

    • @eCivilTech
      @eCivilTech  5 лет назад +1

      Because the value of cf which we get from our code contains both windward and leeward.

    • @vrenzworld
      @vrenzworld 5 лет назад +1

      Hello Sir, can you please let us know where it is provided in code.

    • @eCivilTech
      @eCivilTech  5 лет назад

      @@vrenzworld As our code does not talk about wind ward and leeward for table 30, I.E. table for force coefficient, means it shall be applied on one side only.

    • @vrenzworld
      @vrenzworld 5 лет назад

      @@eCivilTech Table 30 talks only about circular sections, but is it applicable for other sections also, like I and angle section?

    • @eCivilTech
      @eCivilTech  5 лет назад

      @@vrenzworld I'm talking in reference of IS875 (part 3):1987 version, table 30 of this code talks about flat sided sections, which are mostly Angles, or some times it can be RHS, SHS.
      Table 31 of this code is used for rounded sections.
      I and chanel are never used for towers.
      I is good for beam and column. C is good for beam, and double C is best for column.

  • @MukeshSharmaFEA
    @MukeshSharmaFEA 7 лет назад +1

    when will you upload next video for analysis and member design

    • @eCivilTech
      @eCivilTech  7 лет назад

      Next video of this series will be uploaded by the end of December 2017. This month i'm going to upload videos on engineering mechanics. Due to some technical issue our website is not working, and trying to solve that issue, sorry for inconvenience. Thanks for watching videos and commenting. we appreciate your support.

    • @eCivilTech
      @eCivilTech  6 лет назад

      Hi Mukesh, Uploaded the video.. Please share with your friends.

  • @sreenivasuluchenchugari9743
    @sreenivasuluchenchugari9743 4 года назад

    Hi, Please can you respond to my queries below,1. Why wind load applied only on Winward Face and why not on Leedward face2. Wats tha basis for 0.5 deg allowable deflection.3. how about allowable horizontal twist.

    • @eCivilTech
      @eCivilTech  4 года назад

      Hi,
      1. Wind load is applied only in front because rear will be in shadow of front. By the way the coefficient factor given in IS code includes both.
      2. Deflection is totally clients requirement. Client will give you their requirements.
      3. Horizontal twist will be very negligible. As there is no long arm in this particular structure.
      Thanks

  • @mounikakoudhi4128
    @mounikakoudhi4128 6 лет назад +1

    Sir, same pattern design of R.cc structures also

    • @eCivilTech
      @eCivilTech  6 лет назад

      Sure, things are in planning but will take little time. But calculations in this series are in depth. Wind pressure calculation is same for all type of structures. You can apply same in RCC buildings also, only Cf will change according to shape of building.

    • @mounikakoudhi4128
      @mounikakoudhi4128 6 лет назад

      eCivil-Tech. Tq

  • @mahamoudomany8986
    @mahamoudomany8986 6 лет назад

    sir,you didn't remember rru loads on tower. and we need design tower roof top please. .. thanks

  • @neerajarayudu7973
    @neerajarayudu7973 6 лет назад

    Hello sir could you please do tapered slip joint monopole transmission tower in staad model. I am very new to staad and am not civil engineer. Please guide me

    • @eCivilTech
      @eCivilTech  6 лет назад +1

      Hi! You can use PLS POLE software for transmission pole design. You cannot give stress fitting option in Staad pro. Instead you just model your pole as usual, but show overlap in drawing. Length of overlap shall be more than 1.5 times the Dia of female section. In general practice, designer gives atleast 1.75 times of female Dia to overcome the chances of fabrication error.
      Thank you

  • @shahinmahmud4449
    @shahinmahmud4449 2 года назад

    MS TOWER SOFWARE LINK PLZ

  • @gopinayak361
    @gopinayak361 6 лет назад

    I'm still waiting for your uploads sir

    • @eCivilTech
      @eCivilTech  6 лет назад

      Gopi Nayak, planned to complete by Monday. It's year end and students are requesting for help in final project. I know it's already too late but anyhow I'll try to upload on Monday. Thanks for your support and interest.

    • @eCivilTech
      @eCivilTech  6 лет назад

      My friend, uploaded the video :).. Please share with your friends also.. and do let us know how it is made??

  • @Shib.Sankar
    @Shib.Sankar 4 года назад +2

    PLEASE UPLOAD THE FILES

    • @eCivilTech
      @eCivilTech  4 года назад +1

      I found that there is some problem in the link. will upload within two days. Thanks for informing.

    • @eCivilTech
      @eCivilTech  4 года назад +1

      I've uploaded file for video 4. You can download that file for reference. working for other files.

    • @Shib.Sankar
      @Shib.Sankar 4 года назад +2

      @@eCivilTech you're soo good man sir.. i love you❤️❤️❤️ why don't you share your phone number?? Please 🙏 i wanna contact you 🙏🙏🙏

    • @eCivilTech
      @eCivilTech  4 года назад +1

      I've updated all the links for all files. Kindly check and let me know if it is working properly.

    • @eCivilTech
      @eCivilTech  4 года назад +1

      I've deleted your comment in which you've mentioned your contact number for your privacy safety. Kindly never share your contact detail online. You can contact on eciviltech.com/contact-us/

  • @Shib.Sankar
    @Shib.Sankar 4 года назад

    files are not availavel

    • @eCivilTech
      @eCivilTech  4 года назад +1

      May I know which browser are you using? kindly try google chrome browser and let me know if it works.

    • @Shib.Sankar
      @Shib.Sankar 4 года назад

      @@eCivilTech cheacked from Google Chrome mobile and pc both not working sir

    • @Shib.Sankar
      @Shib.Sankar 4 года назад

      @@eCivilTech please provide your phone number i wanna learn from you 🙏