Commercial Rooftop HVAC Unit Not Cooling
HTML-код
- Опубликовано: 14 май 2024
- Commercial Building with MULTIPLE RTU's for HVAC - Finance Office is OUT! Unit Not Cooling
Let's Make The Trades Great Again! Join Mikey Pipes Philanthropy, Inc., an IRS 501(c)(3) non-profit public charitable organization. Our mission is to offer free or low-cost plumbing, heating and cooling services to those in our community who can't afford to hire a professional. Help us here: www.paypal.com/donate/?hosted...
Need a website for your contracting business? Check out Footbridge Media for their amazing special on not only a website but SEO services for only $249/month! www.footbridgemedia.com/?ref=...
Need a CRM or dispatching and invoicing app? Check out HouseCallPro: tinyurl.com/MikeyPipesHCP
What’s in your Veto? Here is mine:
Veto TP-XXL amzn.to/3zX10vg
Testo Combustion Analyzer: amzn.to/3Zd7naH
Digital Manometer: amzn.to/3EDt5ey
Milwaukee M18 Blower: amzn.to/46iTo6j
Milwaukee M12 Fuel 1/4" Impact Driver amzn.to/3I9yLfI
Milwaukee PVC cutter: amzn.to/3sbrdUc
Mini Waterproof Storage bin: amzn.to/3yfgsEv
Wiha Allen Keys: amzn.to/33ipGmb
HIKMICRO B20 amzn.to/33iGklx
Furnace Switch amzn.to/31X89PT
Milwaukee Light amzn.to/3I38Lmh
Wagos amzn.to/34QoiaU
Milwaukee Set amzn.to/33vnQOz
Torpedo Level amzn.to/3no1oOk
Crescent set amzn.to/3GtZeV8
Wiha 7 piece set amzn.to/3rkISaK
Milwaukee step bit amzn.to/3I395Bv
Thermocouple Flare wrench: amzn.to/3noJZ8s
Ridgid 10” wrench amzn.to/3GvRnqa
Fluke non-contact tester amzn.to/31VQgAQ
Klein drivers amzn.to/3qoe21W
Knipex Wrenches amzn.to/3trzFjS
Klein 11-1 amzn.to/3tpsPLD
12” crescent amzn.to/3A0CZ6S
Gerber Gear Pocket Knife amzn.to/3foaW7I
Yellow Jacket Hand Ratchet amzn.to/3nrDgup
I am on Discord & WhatsApp!
Discord: / discord
WhatsApp Group: chat.whatsapp.com/CHZWtZe4KMG...
New oval raised silver stickers are from:
Armored Decal Company Inc.
35 Victoria St. E, Unit 9
Alliston, Ontario L9R 1T3
(p) 705-435-6665
(e) ken@armoreddecal.com
(Tell them Mikey Pipes sent you)
Please support this channel and Mikey Pipes and consider the following…
Pipe Doctor FlexFit Embroidered Caps
Minimum donation of $37 is appreciated
(If you are international - please add a minimum of $40 for shipping/postage)
Shopping on Amazon? Please use my referral link amzn.to/2PjjS4v
Sticker Requests:
Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
Name
Address
City, State, Zip
Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
PayPal is: office@pipedoc.net
Venmo: @PipeDoctor
CashApp: $mikeypipesny
Zelle: mike@mikeypipes.com
Want to send a love letter, note or gift? Our mailing address is:
Mikey Pipes, Inc.
1010 Central Avenue
Woodmere, NY 11598
#hvac #mikeypipes #pipedoctor
Music from #InAudio: inaudio.org/
Other music from MOVAVI STUDIO SUITE 2024 under license by 3:10 Global Holding, Inc. Хобби
#2 Make the trades great again Mikey Pipes. Smash that Like Button folks.
love you.
no
homo
He is an honest tradesman. Would anyone else be this transparent?
Absolutely! Transparency is key in building trust.
Another great production ... Appreciate all your effort ... Thx
Thanks buddy
Thanks for the video Mikey!!! Getting an education from every video! Keep up the great work!
Thanks for watching!
Mikey Pipes couldn't find the unit with the leak till lunch. LOL
When you said you love rooftop units. I thought NOPE, which one.....
Looks like fiberglass ladder, so your good. Unless you are doing the left hand behind back climbing down.
Reading thru the comments i notice everyone keeps forgetting a big part of this trade. The customer ls wallet dictates how far they’re willing to go. Slam the Pipe Doc all you want for the gas n go, but maybe they dont wanna spend the thousands of dollars to replace the coil!
Exactly. People love to just comment without actually thinking
Nice clean video mikey
Thanks Scott
It helps the algorithm
it sure does
What pressure / temp were you looking for on the low side when adding?
Great vid love seeing you guys around town
Its worth it to the customer to do a service call and refill tanks over finding the leak? ? Also its not even hot out yet round here what if the leaks getting bigger and this time youll be out there again in a few weeks?
Will probably be back next year
Careful on that ladder
Love the waygo
Absolutely love Waco
If I’ve never been to system before I gas and go see how long it last then from there I decide what to do ultimately up to customer though
Don’t ya jumper Y/R/G as a cooling call? Or u letting the board run the fan? Hmmmmmmm
May 8th …my sons birthday ❤
Happy belated birthday
@@PipeDoctor thank you Mikey pipes
More rooftop vids
170 thumbs up
Top of the coil is naturally going to be hotter it’s getting sub cooled as it hits the bottom of the coil. That’s normal to feel that temp change about 3/4 of the way down.
Thanks for the wisdom
#1🎉🎉🎉
Congratulations 🎈🎊🍾🎉
Hay Scott M. How's it going up there?
@@scottvolage1752 cold and raining coming back end of June. We miss it in Florida.
It still has gas top it off and move on as you did, time is money!!
Good job!
Thanks!!
You'll be back on this one in a few weeks with all that oil on the condenser coil
We gave a quote to replace the coil last year. Duhhhh
Love gas and go 💴
don't we all?
@@PipeDoctor absolutely.
MICRO CHANNEL ALUMINUM SOLDER REPAIR VERY DIFFICULT!
But possible
Yeah, time to replace the entire coil
If you had to add refrigerant doesnt that mean there was a leak?
Winner winner, chicken dinner
Mikey on a micro channel coil fuck that I will never do that shit again finding a leak way to much time. Gas and Go, let the customer know they have a leak , see how long the recharge last maybe next time shoot some stop leak in it .... but id change the coil out not a fan of stop leak .... Nickyfresh out !!! See you around long island brother I miss the shop over by HD :(
Customer replacing the condenser coil?
We quoted last year. It’s still there
When I get a new unit yall trying to get under 500 microns or nah?
My goal is under 100 µm
Honestly, it is a very noticeable video quality difference. Especially on my 75" Samsung Q LED TV.
Incredible
Mike try serving a RTU on a mall they aren’t ever labeled or number.😮
been there, done that
*cough cough cough* "got some freon in my throat", I didn't know you use "inhalers" 🤣🤣 but seriously, most of them use R-134A as the propellant, breathe deep!
🤭
Mikey Pipes...you must cross the line and fight the internal war within your own country (in order to save the HVAC's potential).
OUCH! I'm a lover not a fighter!
Love you, no homo
That leak is in the bottom corner of the coil. How can you miss that big oil spot. Those coils are junk.
Complete garbage
So you bought the business from the old man in Florida?
More like a merger
@@PipeDoctor : But with a name change!!!💪💪💪
Restaurants are the Very Worst for doing Any Preventative Maintenance on their Rooftop Equipment. They Don’t Care if Cost them more money in long run. 🤪👎
I know. But I still love working on RTUs
Nope I am “ Not “ going to lecture you on them worthless piece of junk, micro channel pieces of crap..(( 😂 can you tell I don’t like them?😂)) but after many many years of serving the gages tell us approximately how low unit is without evacuating and seeing what’s left, it just comes with the art of years of service… but so as not to let you feel un loved …….. Mikey Pipes!! A.. that little giant ladder is not tall enough! An B? I didn’t see a safety rope 😜 rolling on the floor laughing sorry boss man got to give you a little grief ❤ But being honest here most commercials? Just gas and go they do not wanna pay to find the problem. They take the easy route and the cheapest route, but as we both know, sometimes the cheapest route in the end was the most sus expensive.🤷🏻♂️ But I totally agree with you. I love rooftop units other than the communication wire and the T stat? Everything is up there well most everything.. your lead seal fire trap doors are usually down below… yea a question 🙋♂️ does NY require fire dampers in the duct work? Michigan is a pain about it 🤷🏻♂️ but beautiful day to be on the rooftop
We don’t need no stinking fire dampers!
This is hilarious. You shouldn't have pardoned these idiots.
Yeah, you know what I figured. We all deserve a second chance.
Block the trolls
Unblocked them
Not even attempt to find the leak. Gas and go... collect the check and go. Total disservice to the customer
Hahaha! Another rocket 🚀 scientist 👩🔬 who thinks they know everything! Guess you missed the part that we quoted a new coil last year.
Pipe Doctor & Mikey Pipes = BOSS
Cha Ching b!tch
@@PipeDoctor Epic response bro. Keep up the great work!!!!
@@PipeDoctorI heard you're a real loser pretending to have any real certification or license, when you a actually have none.
I heard you got all butthurt when the guys at Navien wouldn't work with you because you're a bum and you only do it for the clicks, likes and your lame ass RUclips channel. Keep smoking, you sound great! @@PipeDoctor
😂
Micro channel is HORRIBLE, all 15 of our Samsung micro channel A/C's failed within 5 years, very poor quality.
Back to "tube and fin". all great!
Microchannel coils absolutely suck ass
If you see Trump while out and about, tell ‘em I said hi!
Will do!