    you can't see the Beam you just placed. Structural Beams are positioned in a negative direction from the level. The view range of an "architectural" plan has the bottom of it set to the height of the level itself. So the structural Beam is being placed below the view range of the view and you can't see it. Visibility and graphics is NOT goin to affect this. To see the structural colums you either need to change the negative offset of the Beam to move it where it will be visible in the view range, or change the view range of the view so it "sees" a bit below the current level so the Beam can be seen.
    As I understand it, the negative offset placement of structural Beams is related to the typical workflow of a structural engineer. They think of plans from the level looking down (floor framing and below is what is critical to them) where architects think of the level as the 4' or so above level of the floor.