MGA KAILANGANG MALAMAN SA REBARS NG ISANG FLOORING. PAANO ANG DEATALYE NG REINFORCEMENT SA SLAB?

Поделиться
HTML-код
  • Опубликовано: 3 май 2021
  • PARAAN AT DETALYE NG BAKAL O REINFORCEMENT SA ISANG SUSPENDED TWO WAY SLAB, MGA KAILANGANG TANDAAN SA REINFORCEMENT NG FLOORING. SUSPENDED TWO WAY SLAB REINFORCEMENT.
    This video is NOT sponsored. Some product links are affiliate links which means if you buy something we'll receive a small commission.
    BUILDMATE: invol.co/cl5y7rd
    Buildmate Online Depot
    Welcome ka dito Ka-BUILDMATE! 👋
    🚧Your One Stop Hardware Shop is always here
    with the most complete home & living needs.
    Be updated with our Special offers because every day
    is Guaranteed LOWEST PRICE with us 🎉
    ✨DAILY VOUCHERS GIVEAWAY with just one click
    in our ✅FEED Section & Chat button.
    plus our Special 🚛 FREE SHIPPING deals
    What are you waiting for?
    Follow us and Get a Voucher now!
    Home improvement design (Art Design PH): invol.co/cl5lx7p
    Online Shopping Platform (LAZADA PH):invol.co/cl5lx98
    Shop Online Specialized in hard to find items (Galleon PH): invol.co/cl5lxab
    The Ultimate online shopping Experience (Ubuy PH): invol.co/cl5lxdb
  • ХоббиХобби

Комментарии • 195

  • @gerardocampo5526
    @gerardocampo5526 2 года назад

    Thank u po sir harry

  • @oliversaladino2348
    @oliversaladino2348 Год назад

    thanks Engr Gab

  • @ginengineerkamote3815
    @ginengineerkamote3815 Год назад +1

    Hello Engr. Yung Extra bar po ba ang ibebend dyan don sa may L/4?

  • @civilengineeringbdtech431
    @civilengineeringbdtech431 2 года назад

    Very Good Job Thanks 👍

  • @alvinrom970
    @alvinrom970 Год назад +1

    ganda ng paliwanag mo sir tamang tama magpapaslab po ako.. many thanks more power po

  • @jay-arrecto9867
    @jay-arrecto9867 2 месяца назад

    Sir, san ba makakatipid sa steeldeck ba o sa conventional 4 na palapag,, kasi sa steeldeck permanent na while in plywood pwede pa magamit in next floor slab

  • @racgenechannel1992
    @racgenechannel1992 3 года назад +1

    full support boss shout out po

  • @jehielperegrino5453
    @jehielperegrino5453 Год назад

    Good day engr. Ano po ba tlga ang totoong pormula sa pagkuha depth and breath ng beam?
    Kc sa mga blog nyo sinasabi nyo distance in meter converted to feet at kung ilang feet yon ay convert nman sa inches. Halimbawa 3 mts ang distance, yun ay 10 feet, so ang depth ay 10 inches, at ang breath ay 19 over 1.5 so magiging 6.6 inches or 7 inches.
    Samantalang ang sinasabi po sa books ay distance over 16, yun ang depth.

  • @waraynonch.8972
    @waraynonch.8972 3 года назад +1

    Two way slab ang gusto ko na may crank bar....😘

  • @renzpusanggalavlog8202
    @renzpusanggalavlog8202 2 года назад

    Salamat po sir, bagong subcribe po sainyo sir

  • @relaxtv5067
    @relaxtv5067 3 года назад +1

    Sir gab.. Pa topic nmn po ng concrete fence. Thanks po s informative vids.

  • @dennismagno2
    @dennismagno2 Год назад +1

    Gd afternoon Engr Gabs.
    Related ito sa una kong tanong regarding sa biga. Ang tanong ko ay paano at ano size ng mga def bars ang dapat gamitin sa 6m x 5.5 steel deck reinforced concrete flooring. Thanks

    • @GabsRomano
      @GabsRomano  Год назад +1

      Along short span bottom 12 mm , along long span 10mm po spaced at 0.20 m oc

  • @Engr.OyoboinkTV
    @Engr.OyoboinkTV 11 месяцев назад +1

    salamat po sa information na to engr!!!

  • @hanesfa.01
    @hanesfa.01 8 месяцев назад

    Xallamat sir!

  • @perlitocaballa1551
    @perlitocaballa1551 3 года назад +2

    salamat bossing idol may natutunan naman ako galing mo talaga idol godbkess always

  • @noelsy764
    @noelsy764 2 года назад +2

    Salamat po Sir sa mga lecture ninyo po marami akong natutunan sa mga turo mo Godbless po Stay Safe

    • @GabsRomano
      @GabsRomano  2 года назад +1

      Thanks for watching and have a great day

  • @josecondez3546
    @josecondez3546 Год назад

    Subscribed. Thank you Engr. Gabs Romano. Dami kong natutunan. 👍🏼🇵🇭

  • @reyelectrical
    @reyelectrical 3 года назад

    Informative boss thanks po sa kaalaman na tatak ko na bahya mo sir kaw na bahala sakin gobless.

  • @ryangarachico2756
    @ryangarachico2756 2 года назад +1

    Idol qu to sa pag papaliwanag madaling intindhin marami ka matutunan bawat video🥰🥰🥰

  • @edpaniagua2920
    @edpaniagua2920 2 года назад

    hello sir. my crack po sa beam ng 2nd floor slab nmin. anu po ang mgandang solosyon

  • @binabdillah5158
    @binabdillah5158 3 года назад +3

    Maraming salamat ito ung hinintay ko Sir... 🥰

  • @jeguimar8720
    @jeguimar8720 3 года назад +4

    Napaka laking tulong ng mga video niyo engr. Lalo na sa mga magpapagawa ng bahay..salamat po, more power.

  • @renzpusanggalavlog8202
    @renzpusanggalavlog8202 2 года назад

    Anu po ba maganda n ma advice nyo po sakin, salamat po sir

  • @dennismagno2
    @dennismagno2 Год назад

    Gd afternoon Engr Gabs.
    Pwede ba ako magtanong sayo tungkol sa tamang size ng biga at tamang dami at size ng def. Bars sa steel deck na 6m x 5.5m na sukat. Napapanood ko na ang mga dati mo vedios. Thanks.

  • @chesteryodong8718
    @chesteryodong8718 Год назад

    Idol sa 5 stories residential sa standard spacing slab 24ft to 33 ft lapad haba 2 way sana maraming salamat idol

  • @ILOCANOngIGOROT
    @ILOCANOngIGOROT 2 года назад +1

    Sir Gab saan po ba dapat ang lapping zone ng main bar at distribution bar?

  • @kennethtayona5320
    @kennethtayona5320 3 года назад +2

    galing nyo po mag turo sana madami pa kayo videos sir..... ito yung matagal ko na hinahanap.... more videos thanks

    • @GabsRomano
      @GabsRomano  3 года назад +1

      salamat po sa pagtangkilik

  • @redo4510
    @redo4510 2 года назад

    Sir ano po gagawin kung yun ikakabit na steel deck may biga na o beam. Thank you po

  • @acechannelinternational8120
    @acechannelinternational8120 2 года назад

    Engr, ano ba ang Structural Engineer sa Civil Engineer? "Specialist" ba ang Structural Engineer?

  • @dadoespela3020
    @dadoespela3020 2 года назад

    good evening Engr. You hae a very nie and simple explanation about two way slab. Appreciate if you can provide me an answer. Gusto ko pong lagyan ng stuctural concrete with rebars ang existing open canal na gawa ng DPWH sa gilid ng highway na may open width na 1meter at 6meters long to be access by 20 tonner capacity dump truck. What is the correct recommend size of rebar and spacing for 4 or 5 inches thick of concrete? Salamat po.

  • @chatytresvalles2075
    @chatytresvalles2075 2 года назад

    Sir pwidi po ma tanung sukat po ng corbel po.sukat ng pag baluktot.po ng bakal.maraming salamat sana mabasa nyo po comment ko.

  • @gretchengalvez681
    @gretchengalvez681 2 года назад

    kapag po ba steel decking ang ginamit na porma sa suspended slab ay one way slab reinforcement na ito? tnx po

  • @seanandrewsoriano2635
    @seanandrewsoriano2635 3 года назад +1

    hellow sir. baka nmn pwede sa beam nmn po kung panu. salamat po

  • @markarjaydechavez5954
    @markarjaydechavez5954 3 года назад

    Engr. Paki share nmn po ng knowledge nyo regarding sa pag footing ng mga poste na naka inclained ang lupa let say 2meter ang difference. Ano po yong tama wala pa kasing naka pag topic nito sa RUclips. Thanks.

  • @Jo-fp3nd
    @Jo-fp3nd 10 месяцев назад

    Good day po. Ask ko lang po if okay lang po ba yung 125mm na slab na may 10mm diameter rebar na may 200mm spacing bothways taposmay CHB wall po na kinecarry?
    P.S. wala pong beam sa ilalim ng CHB walls

  • @yajpipoy8856
    @yajpipoy8856 2 года назад

    Sir ano spacing ng rebar sa swimming pool?

  • @victorpineda130
    @victorpineda130 2 года назад

    San po kayo puedeng macontact just in case mangailangan kami ng Structural Engineer.

  • @noypereyra6719
    @noypereyra6719 2 года назад

    Sir Gabs magkano po ba mag pagawa ng plano ng bahay rowhouse po e2 balak po namin gawing 3rd floor salamat po sa pag tugon

  • @albertosandiego3010
    @albertosandiego3010 2 года назад

    Sir Tanong lang po alin po b mauunang ilatag n rebars s beam longer span o shorter span

  • @06sheryl1
    @06sheryl1 2 года назад +2

    Thank you so much sir. Questions lang po san po nanggaling at para san yung L/4?

  • @user-jy2pc8ci5n
    @user-jy2pc8ci5n 7 месяцев назад +1

    Ser Anong porpos ung 2way

  • @dennisganas6277
    @dennisganas6277 2 года назад

    Thanks for the info sir.

  • @automatic3832
    @automatic3832 2 года назад +2

    mas ok ba gamitin ang GRADE 40 sa 2-way slab sir?

  • @joshualastimosa5713
    @joshualastimosa5713 Год назад

    HUHUHU THANK YOU SIR!!!

  • @superboyvaldez6030
    @superboyvaldez6030 3 года назад +1

    Mahilig talaga aq manood ng mga ganitong topic kc po wala pa po aq bahay, so maraming salamat unti unti q ng nauunawaan ang mga kailangan q malamang sir. Tanong q lang sir 3×6 na sukat wala na aq building permit wala ba aq lalabagin na batas sir, someday maging 2 story's sir

    • @GabsRomano
      @GabsRomano  3 года назад +1

      3x6m kung isang palapag lang sa pagkakaalamq di na need ng permit, di q lang alam pag 2 storey

  • @officialtakedown5169
    @officialtakedown5169 2 года назад

    Ayos ka bossing mabuhay ka.!

  • @rhaikuaika
    @rhaikuaika Год назад

    GOod eve Engr. sana po masagot nyo.. 5.60meters by 3.70meters ok lng po ba walang crank bar? continous po lahat bakal na 12mm main bar 10mm tempbar.. ano po pwede nyo recommend salamat po.

  • @johntoledo3429
    @johntoledo3429 2 года назад +1

    Sir matibay ba ang slab na nakapatong sa beam?

  • @rogue66v
    @rogue66v 2 года назад

    hello po, maxado po ba malayu distancing if 6m width yung flooring at .75mm rebar distancing? bale 8 na rebars po sa 6m na width

  • @alfielago
    @alfielago Год назад

    Sir gusto ko lang po sana magtanong kung kailangan po ba lagyan ng rebars Ang flooring ng bonggalo house. Maraming salamat po. Electrical po kasi ako gusto ko lang po matuto.

  • @castelobanlaygas1930
    @castelobanlaygas1930 3 года назад +1

    Hi engineer nalilito ako. Sabe nio ilagay ung main bar sa shorter distance likewise sabe nio rin ganun din dpt sa steel decking.. Pero bkt sa video po na to parang baliktad pagkakailustrate mo or paglalagay mo ng sa main bar.... Or baka ako ang mali sa pagiintindi

    • @GabsRomano
      @GabsRomano  3 года назад +2

      sa steel decking po pwede either way kc nsa along shorter npo mismo ung steeldeck materials.

    • @castelobanlaygas1930
      @castelobanlaygas1930 3 года назад

      @@GabsRomano salamat po engineer, great help po

  • @adrianovergara1784
    @adrianovergara1784 3 года назад +2

    Ang galing Sir napakalinaw po ng paliwanag mo.

  • @macharrysabares4932
    @macharrysabares4932 Год назад

    thank you po. very informative

  • @mikeordonez1395
    @mikeordonez1395 2 года назад +1

    Very educational sir. Malinaw po ang pagpapaliwanag mo. Malaking tulong sir.

  • @Designer_504
    @Designer_504 8 месяцев назад

    Yung bent up bars po ba is considered nadin na top bars? Nasanay po kc ako sa curtailed na slab, salamat po😊

  • @larrygabito9844
    @larrygabito9844 3 года назад

    Sir bkit parang iba po ang practice mg slab reinforcement specially two way slab about sa top bar po sa RUclips un top bar po is un na mismo un pinakaextrabar while encounter q po sa site is un top bar is continuous bar din tapos saka mgdagdag ng extra bar sa slab edge

  • @burtreynolds4917
    @burtreynolds4917 2 года назад

    Sir gab.. anu purpose nang crank bar po..?

  • @the_explorer5356
    @the_explorer5356 2 года назад

    Sir ask lang ano po ang dapat gawin balak ko kasi sana mag pagawa ng 2nd floor...kaso yong budget kolang pwdi pobang i abang konalang sa beam or buhusan ng buo ang beam at ipatung nalang ang slab or buhusan ng higit sa kalahati? Tnx po

  • @chatytresvalles2075
    @chatytresvalles2075 2 года назад

    About corbels po sana sir need lang po ng husband ko sa work.

  • @user-de9kr1ts7n
    @user-de9kr1ts7n 5 месяцев назад

    galing mag explain sir idol engr. Thnk you

    • @GabsRomano
      @GabsRomano  5 месяцев назад

      Thank you for the support 🙏

  • @djmarlonremix
    @djmarlonremix 2 года назад

    Boss paano po kung ang bahay na 20"x16" ay nagawa na na mayroong 8 posti at gustong dagdagan ng 2nd floor pero ang posti ay 4 na 10mm lang ang bakal. Pero meron itong cross beam lahat sa taas at 10mm din ang bakal. Kaya po ba e slab?

  • @bobbyalcera8279
    @bobbyalcera8279 2 года назад

    Maraming salamat po sir.. Natututo aq s mga upload vedios mo po..

    • @GabsRomano
      @GabsRomano  2 года назад

      thanks for watching and have a nice day sir

  • @haroldavecilla9375
    @haroldavecilla9375 2 года назад +1

    Sir thank you so much marami kang ma tutulongan lalo na sa mga kagaya ko. be safe sir more blessings god bless sir!!!

    • @GabsRomano
      @GabsRomano  2 года назад

      Have a great day po salamat

  • @MarvinLibio
    @MarvinLibio Месяц назад +1

    Sir,tinatali ba ung bottom bars nga slab sa beam?

  • @alvinparalejas1936
    @alvinparalejas1936 8 месяцев назад

    sir pahingi naman ng pdf manual nyo ng coding system

  • @hazelbillones2678
    @hazelbillones2678 Год назад +1

    Sir gab ok lng Po ba 9mm gamitin na anilyo para sa column 12mm tapos naka roof deck.. thank u Po..

  • @josejasongalo2199
    @josejasongalo2199 2 года назад +1

    Bagong subscriber mo Sir pa notice...wla akng alam s tinuturo s video n ito pro mahilig ako manood s mga video mo...mahilig akng mag DIY...tanong ko lng ano ba yang L/4?

    • @GabsRomano
      @GabsRomano  2 года назад +1

      inexplain q po sa isa q pang video sa "tamang dugtungan sa biga"

    • @josejasongalo2199
      @josejasongalo2199 2 года назад

      @@GabsRomano slamat sir god bless keep safe

  • @fbarontv7266
    @fbarontv7266 3 года назад

    Sna dalawin mo rin ako kabayan

  • @thelmaolonan349
    @thelmaolonan349 2 года назад +1

    Sir 12mm din po ba ggamitin sa slab gamit ang steeldecking?

    • @GabsRomano
      @GabsRomano  2 года назад +1

      Pwede na 10mm, kung gagamit ng 12mm dapat along shorter span

  • @ceazarnacion8090
    @ceazarnacion8090 2 года назад +1

    Engineer , how to determine the distance Ng bakal Ng floor deck

    • @GabsRomano
      @GabsRomano  2 года назад +1

      for practicality nasa brochure po ng metal decking

    • @ceazarnacion8090
      @ceazarnacion8090 2 года назад

      Sorry po engineer, Ang ibig Kung itanong is Ang bakal Ng second floor slab na may distance Ang columns Ng 3.5m paano ko ma compute Ang distance nito single po

  • @elycotanas5945
    @elycotanas5945 3 года назад +1

    maraming salamat sir. very impormative. sana mayroon pang iba.

    • @GabsRomano
      @GabsRomano  3 года назад

      marami pa po sir, salamat sa pagtangkilik

  • @rolanddelacruz8618
    @rolanddelacruz8618 Год назад +1

    Ok lng po ba engr ung spacing ng slab na main bar 20mm tpos ung dist. Bar 30mm using 12mm bar sa 6inch na thickness ng slav.salamat po

    • @GabsRomano
      @GabsRomano  Год назад +2

      Pag hindi po typical ang design need pa STAAD

  • @geraldenejustol7040
    @geraldenejustol7040 3 года назад +1

    Sir pwede pa request pwede isa isahin kong ano mga pangalan at style kasi po dko pa alam mga pangalan ito po sample ito ay beam ito ay bega ganun po ba sir

    • @GabsRomano
      @GabsRomano  3 года назад +1

      ung beam saka biga pareho lang po , ung ang nakapaikot sa flooring, ung slab at flooring pareho lang po ibig sabihin at ung bakal,rebars at deformed bar eh reinforcement po lahat un

  • @marvintapar6063
    @marvintapar6063 3 года назад +1

    God bless po ser. Tuloy nyo lang po . Marami po kayo natutulungan. Hindi ako nag skip ng ads hehe🤗

    • @GabsRomano
      @GabsRomano  3 года назад

      maraming salamat ser and God Bless po

  • @jomarcdariguez1595
    @jomarcdariguez1595 2 года назад +1

    Not CE po. Ano po yung load or weight na kayang buhatin ng ganyan na design? Yung total

    • @GabsRomano
      @GabsRomano  2 года назад +1

      typical residential po and if not need na ng structural analysis. thanks for watching

  • @eugenetugano3769
    @eugenetugano3769 2 года назад +1

    Gud am sir. What if wala ng cold joints sa slab pero gusto ko palagyan ng column, possible po kaya at maglagay pa ng another slab on top of it? Thanks in advance.

    • @GabsRomano
      @GabsRomano  2 года назад +2

      need nio po linisin ung contact point and in some practices nilalagyan ng cement grout para ma cure ung surface incase na may cracks na.

  • @densyrawr9626
    @densyrawr9626 3 года назад +4

    Sir ask ko lang po kung pede ng gamitin 10-16mm sa 9 na column na ang bahay po ay 8x8 mtrs 3 storey??

  • @jaybangayan6255
    @jaybangayan6255 2 года назад +1

    Ano ang magandang gmitin if mei kabuyang sukat n 7 x 6,,tpos magkakaroon ng 4 span,,2 way b n 10mm or 2 way n 12mm,,tnx po,,,

    • @GabsRomano
      @GabsRomano  2 года назад

      2 way slab with 10mm deformed bar 4 areas. thanks for watching

    • @jaybangayan6255
      @jaybangayan6255 2 года назад

      @@GabsRomano ano ang spacing sa main bars at sa distribution bars,,,tnx eng'r

  • @user-jy2pc8ci5n
    @user-jy2pc8ci5n 7 месяцев назад

    Tanong ko lang po Kong pweding asintadahan ung overlop hanga dalawang palapag salamat

    • @GabsRomano
      @GabsRomano  7 месяцев назад

      as long as nka proposed or may beam supports.

  • @rogerdabalos2597
    @rogerdabalos2597 2 года назад +2

    Sir Good day, ask lang po regarding standard hook of rebars ng conventional suspended slab at the end of the slab or at beam support. Thanks Sir! More power

    • @GabsRomano
      @GabsRomano  2 года назад +3

      pag continuous wala po hook, pag end slab development length. Thanks for watching

  • @datubimboromatho4506
    @datubimboromatho4506 2 года назад +1

    Sir paano hindi tumagas ang tubig sa slab o flooring sa taas ? Ano ang technik diyan ?

    • @GabsRomano
      @GabsRomano  2 года назад +1

      Mahal po ang pawater proofing kaya ang gnagawa q inaaplyan q ng flintcoat # 2 and #3. Thanks for watching

  • @edmarcabalan9491
    @edmarcabalan9491 3 года назад

    Sir halimbawa steeldick ang gawin slab ano ba ka thickness ng cemento

    • @GabsRomano
      @GabsRomano  3 года назад

      4 in parin po pag residential as long as theres no occasional heavy load sir

  • @dondongoles5493
    @dondongoles5493 2 года назад +1

    Sir gabs,plano ko magpagwa ng slab,pano ang style kong my mga beam na?

    • @GabsRomano
      @GabsRomano  2 года назад +1

      need po may bakal na kakapitan, kung finish beam npo, pwede na ipatong same po sa method ng w-beams, Thanks for watching

  • @geneseloft7692
    @geneseloft7692 3 года назад +1

    Sir paano ung 2 storey n bahay balak ko ipa slab ung steel roof ng second floor,ok lng b kung ipababasag ko ung kalahati ng roof beam pra maipasok ko ung mga bakal ng slab or pagagawa ulit ako ng panibago n beam ?

    • @GabsRomano
      @GabsRomano  3 года назад

      Need po nyan ng as built plan at actual site visit para po macheck kung paano magandang paraan sir

  • @uekihunter752
    @uekihunter752 3 года назад +2

    Bossing kung my steel deck OK lng ba na walang bend bars o crank bars?

    • @GabsRomano
      @GabsRomano  3 года назад +2

      gawa po aq ng ganyang video soon po

  • @samuelmillorenii1784
    @samuelmillorenii1784 2 года назад

    Good eve sir, ask lang po pwidi ba yong 16 mm para sah slab...

  • @drawingtable8802
    @drawingtable8802 2 года назад +1

    Sir pano kung 2 ang lumabas sa ratio 4/2=2 (1way po ba or 2way). Second question po, in determining the Bar Diameter, kung ang Slab Depth po ay 200mm? Lalabas 24mm Dia ang Bar. Kaya po ba 2 layer? 10mm Top, and 10mm sa Bot?
    Champion kayo sir, thank you sa mga videos nyo!

    • @GabsRomano
      @GabsRomano  2 года назад +1

      1 way po, kc ang condition is less than 2 but not = 2, kung 200mm thck slab, mas ok kung pa structural analysis kc may effect sa collumn and foundation. Thanks for watching

  • @mva6213
    @mva6213 2 года назад +1

    nakawelding po ba ang mga bakal?

    • @GabsRomano
      @GabsRomano  2 года назад +1

      Tie wire po mas cgurado kc may tendency na bumitaw ung hinang.

  • @ravenventura3414
    @ravenventura3414 7 месяцев назад

    Boss ano po dapat gamitin sa conventional 10m by 7m po ang sukat pwede ba 1 way slab jan?

    • @GabsRomano
      @GabsRomano  7 месяцев назад

      check po ang ratio ng width and length , ask someone to inspect it with knowledge and see my other videos po.

  • @renzpusanggalavlog8202
    @renzpusanggalavlog8202 2 года назад +1

    Ask ko lang po sana sir nagpagawa din po ako nang bahay at balak kopo sana ipa steel deck 18x20 po ang laki nang bahay kaso po sir sa taas may mga dinagdag na lapad paikot mga isang metro kaya lumapad sa taas

    • @GabsRomano
      @GabsRomano  2 года назад +1

      kung ipapa steeldeck po , pwede lagyan paikot ng beam para may proteksyon ung decking materials from corossion kung nag lagay pa ng 1m overhang.

  • @diomedescardenas1914
    @diomedescardenas1914 2 года назад +1

    Sir ..Pwede po ba ang slab 6m x 3.7m in two way slab in 10cm thinkness concrete by 20cm reinf distancing with both side paikot with beam 20x40cm .........please rply thanks.

    • @GabsRomano
      @GabsRomano  2 года назад +1

      Two way cya may beam between 6m span po sana. Thanks for watching

    • @diomedescardenas1914
      @diomedescardenas1914 2 года назад

      @@GabsRomano thanks po

  • @sweaterboston7751
    @sweaterboston7751 3 года назад +1

    Sir mgtanong lng ako kc ngpagawa ako ng slab sa 4thfloor,,medyo pinagaan ko un gawa..kaso nong ngawa na sa bandang gitna pag may tumalon nagkakaroon ng vibrate..ano po kaya mgnda gawin sir,sna mpayuhan nyo ako

    • @GabsRomano
      @GabsRomano  3 года назад +1

      maaaring kailangan ng stiffener/tie beam po, sa experience q po nung nalagyan ng floor tiles nabawasan ung vibrate.

  • @robertdionne6073
    @robertdionne6073 7 месяцев назад

    👍👍👍

  • @tommacabulostoledo
    @tommacabulostoledo 3 года назад

    Ayos, idol! Always following your videos! highly informative!
    Boss, tanong ko lang, kung sakaling di matapos or kailangang ihinto ang pagbuhos ng beam at slab, ano po ang mabisang gawin at saan banda or area po natin eto i terminate ? Maraming salamat Sir, Mr. Gabs Romano, IDOL!!!

    • @GabsRomano
      @GabsRomano  3 года назад +2

      please see my upload " POURING and LAPPING of column"

    • @tommacabulostoledo
      @tommacabulostoledo 3 года назад

      Salamat Sir Gabs!

    • @bagice9313
      @bagice9313 2 года назад

      Big help sir! Thankyou po!, Godbless!!!

  • @markedisoncortez2117
    @markedisoncortez2117 3 года назад +8

    3 years na akong civil engineer pero di ko alam kung bakit nandito ako HAHAHAHA

    • @raybacasmas511
      @raybacasmas511 2 года назад

      Mark Edison Cortez sa kapapanunuod mo ng video ibig sabihin nyan you have insatiable desire to learn, it’s good, but the best teacher is actual experience. You can pick up learnings from Engr Gabs & apply it in your own or workplace. God bless 👍

    • @benitobalneg6947
      @benitobalneg6947 Год назад

      Is there something funny?

  • @jeffbarrientos9363
    @jeffbarrientos9363 2 года назад +1

    Pde sir na i combine ung dalwa 12 ung sa ilalim saka 10mm sa top

  • @robertbigueja5988
    @robertbigueja5988 Год назад

    May tanong lang po ako at sana po ay mabigyan nyo ng kasagutan, ano po ba ang sinasabi sa plano na hanger bars sa slab rebars? Salamat po

  • @andrewes1278
    @andrewes1278 2 года назад

    Hi po sana masagot. Ung 2nd floor slab po nami nag vivibrate kahit simpleng lakad lang. Sabi nang tatay ko malaki daw ang bakal nun, pero manipis lang ang cementeto. Pag pinatungan namin nang another flooring para kumapal ang cemento, ma reresolve ba ang vibration issue ng sahig?

  • @michaelisaguirre1104
    @michaelisaguirre1104 3 года назад +1

    Boss tanong KO LNG po gsto gawin semento un sahig ng bahay KO gawa sa kahoy un sahig KO

  • @thomasbenafin9530
    @thomasbenafin9530 2 года назад +1

    Sir gab safe ba gamitin ang grade 33 na rebars sa 3 story building?

    • @GabsRomano
      @GabsRomano  2 года назад +2

      Check design and analysis parin po kc 3 storey.

    • @thomasbenafin9530
      @thomasbenafin9530 2 года назад

      @@GabsRomano maraming salamat engr