Motor Control: Forward Reversing Starter

Поделиться
HTML-код
  • Опубликовано: 23 май 2019
  • #accesstopower #MotorControl #AccessElectric
    accesstopower.com
    In today's episode of AccessToPower we will wire up a forward reversing starter. We will show how the mechanical and electrical interlocking works and how to do a proper forward and reversing starter in order to keep personnel and equipment safe. There are many different ways to achieve a forward and reversing starter setup. This is one of those methods.
  • НаукаНаука

Комментарии • 121

  • @Manchessollte421
    @Manchessollte421 3 месяца назад +1

    dude this is amazing, thank you so much. having an ACTUAL MOTOR is going next freaking level. thank you.

    • @AccessToPower
      @AccessToPower  3 месяца назад

      Thank you. I appreciate the comment.

  • @Steven-qs6wj
    @Steven-qs6wj 5 лет назад +19

    I am binge watching your videos lol. Refreshing on everything and you are a tremendous teacher. Thank you.

  • @nickmctiernan6979
    @nickmctiernan6979 3 года назад +6

    Wow. If only every Jman could explain topics like you do. Break it down wonderfully and kept it simple. Love the schematic drawing on the side that highlights what's live and what is not. I'm sure that will help with more complicated wiring.

  • @theprophet4233
    @theprophet4233 3 года назад +2

    Give this man a raise. You have simplified this way better than the computer learning we are currently doing. I commend you for all the work you do and all the help you have given us.

  • @Loredo_1
    @Loredo_1 Год назад +1

    Thanks to your video I passed my mine electrician test, and be making almost 60/hr 😎

  • @xavierramirez2196
    @xavierramirez2196 Год назад

    Very well explanation thanks for not being in a hurry like the last guy!!!

  • @RaymondBurton
    @RaymondBurton 3 года назад +1

    This is great and much appreciated. Refreshing my memory for garage door openers and this is exactly what I need to see. You explain everything very clearly. The wiring diagram on the side is PERFECT. It crosses the bridge between the paper and real world application.

  • @evanherpin6980
    @evanherpin6980 4 года назад

    This is a pretty comprehensive and well done video, thank you!

  • @andyramone8497
    @andyramone8497 2 года назад

    You are the best teacher ever!!

  • @aladdindorado3608
    @aladdindorado3608 4 года назад +1

    Thank you for the very clear demonstration.

  • @jesusmylife6766
    @jesusmylife6766 3 года назад +1

    Within the first 2 mts I liked your lecture, I can't wait until I finish the video to subscribe. You are the man.

  • @Talinthis
    @Talinthis 4 года назад +7

    this is incredible with the diagram in the corner. in most video's you just see people connecting stuff but you dont know what the contactor is labeled or what terminal they are putting it in.
    I have installed and wired pretty much every device in industrial construction in the field, but sadly not even once have i had the opportunity to actually wire any contactor, relay, or any control related device.

  • @james.8985
    @james.8985 5 лет назад +2

    Thanks mate absolutely love watching your vids. Keep up the great work👍
    Brisbane Australia

    • @AccessToPower
      @AccessToPower  5 лет назад

      James. Thanks for commenting on our video, and welcome from Brisbane!

  • @kamilkarakaya1887
    @kamilkarakaya1887 Год назад

    Thank you very very much. It is very helpful.

  • @Taylor-op8tv
    @Taylor-op8tv 3 года назад +1

    Yeah, this was great man thanks for the refresh.

  • @adanarceo4636
    @adanarceo4636 3 года назад +1

    Very impressive sir, I was wondering what would happen if you turn on the reverse button while the forward started was on, but you just did it right away.
    Very cool presentation.
    Thanks for sharing.

  • @noeldelrealaguirre3916
    @noeldelrealaguirre3916 5 лет назад +9

    Thanks you so much for your videos! I'm currently going to college to get my elec. Certification and they really helped alot. Much appreciated man.

    • @AccessToPower
      @AccessToPower  5 лет назад

      Noel, I am glad the videos helped you through your college classes. Thanks for letting me know they helped you. It encouraging!

  • @derrickfettig100
    @derrickfettig100 5 лет назад +2

    Thanks for the videos!

  • @stanleykania7184
    @stanleykania7184 4 года назад

    I keep watching, so when the time arises I will be ready

  • @Automationacademytv
    @Automationacademytv 4 года назад

    Thanks Walter I always watch your video

  • @thevalinor8282
    @thevalinor8282 3 года назад

    Thank you, thank you, thank you ! I finally understand how to set it up

  • @mgqubasihle3342
    @mgqubasihle3342 4 года назад

    Good teacher ,I like his lessons

  • @stanleykania7184
    @stanleykania7184 4 года назад +1

    Love your videos.

  • @brady0630
    @brady0630 Год назад

    these videos are priceless

  • @athilaldurry5880
    @athilaldurry5880 2 года назад +1

    Many thanks for wonderful information

  • @velasquezc4
    @velasquezc4 Год назад

    This video is so good! Thank you!

  • @Idrathernot.
    @Idrathernot. Год назад +1

    I love your videos man!

  • @romanusoduwole713
    @romanusoduwole713 2 года назад +1

    enriching video presentation, please will like to learn more on electrical controls from you

  • @OrlandoMartinez-bx9tg
    @OrlandoMartinez-bx9tg 2 года назад +1

    Great work on teaching us, you are meticulous on how to explain functionality, thank you for doing that I understand more from your videos which I greatly appreciate thank you Sir

    • @AccessToPower
      @AccessToPower  2 года назад

      Thanks for your positive thoughts and comments! I appreciate it!

  • @danielteyehuago1633
    @danielteyehuago1633 2 года назад +1

    Thanks for your sharing it with us. This is a great tutorial and very informative...
    dl

  • @matthewmiller4177
    @matthewmiller4177 4 года назад +1

    Your videos are awesome I'm going to school for a associate's of applied science in industrial technology and your lessons are exactly what I'm learning in motor controls

    • @AccessToPower
      @AccessToPower  4 года назад +1

      Thanks Matthew for the comment. I am glad you are finding the content here helpful. Much success in your studies!

    • @matthewmiller4177
      @matthewmiller4177 4 года назад +1

      @@AccessToPower I need to sharpen my ladder diagram skills far as labeling could you post a video on that please mainly what should be labeled and a clean readable way to label thank you so much

  • @rimasp4769
    @rimasp4769 2 года назад

    Amazing video

  • @calonarv1453
    @calonarv1453 Год назад +1

    Que bien lo explica., gracias!!

  • @vinmansucc2698
    @vinmansucc2698 3 года назад +1

    Very nice thanks

  • @ericweiden6232
    @ericweiden6232 3 года назад +1

    Access electric by far the best hooray hooray for Access electric

  • @PolygonMatic14
    @PolygonMatic14 5 лет назад +1

    Excellent nice presentation i learn more about your channel teach more im just a begginer

  • @TechTricks786
    @TechTricks786 4 года назад +1

    Good job

  • @lauroolmos3362
    @lauroolmos3362 4 года назад +3

    Thank you these videos helped me so much.... bad **s

  • @charlie774751
    @charlie774751 4 года назад +1

    So amazing

  • @wakeup215
    @wakeup215 4 года назад +1

    thank you so much

  • @bamideleabdulmajeed1917
    @bamideleabdulmajeed1917 4 года назад

    Nice presentation sir

  • @johnle1465
    @johnle1465 Год назад

    Good morning - thank for sharing your knowledge. Please share part number for switches that you're using in the video. Thank you Sir.

  • @hhr1985
    @hhr1985 3 месяца назад

    I always teach to only swap A & C phase to reverse the phase rotation. This prevents accidentally burning stuff up in the rare time one may have to deal with the high leg on a 120/240 3 phase feed. (Code here is the high leg must be on B Phase)

    • @AccessToPower
      @AccessToPower  3 месяца назад +2

      That is a good idea. Especially if the control voltage is 240 volt delta. But it is a good practice to teach newbies as it eliminates possibly making a mistake when the voltage, or high leg information is not understood or known. And yes, High Leg is most often on B Phase in the field... but there are some utilities that provide the high leg on C phase and it must be switched after the MSB to B phase on all Panelboards, and MCC's. This too can be a bit confusing and cause people to make mistakes. Thanks for your comments and sharing your best practices with the community.

  • @nspresents6699
    @nspresents6699 3 года назад

    you are a very good teacher thank you very much. would you please tell me the simulator name and where we can find it ?

  • @johnnystoka6625
    @johnnystoka6625 Год назад

    Would like to see that done for a single phase motor .

  • @swetunafpv1856
    @swetunafpv1856 2 года назад

    Is there a schematic for this somewhere? This is very useful

  • @mikehessock8277
    @mikehessock8277 4 года назад +1

    Could you add the terminal numbers? 13/14, 95/96? as example. I have found that this helps students keep track from the drawings to the components. No complaint just a suggestion. Great videos, well done and easy for folks to follow. I like how you split screen to show component and drawing simultaneously.

  • @kenhuff9136
    @kenhuff9136 3 года назад

    Can you do a video of a VFD with a remote switch control with an E-stop and, an of/on switch, a forward/reverse, and a potentiometer all to be used in a milling machine. The drum switch currently on the machine reverses almost instantly (needed when tapping); it is not necessary to stop the motor and then energize the reverse switch.

  • @RGL642
    @RGL642 11 месяцев назад

    Nice in depth explanation video. I'm looking for info just like this. I am looking to wire up something like this for my cargo lift in my garage, three phase worm gear drive motor system. Looking to have EMO, up and down fixed on second floor and the same for first floor. Also looking to have one on the platform wall so when I'm riding it. Would the switches need to be three way.

    • @AccessToPower
      @AccessToPower  11 месяцев назад

      Nice! This could work, but you also may want to add limit switches for the “at top” and “at bottom” locations which break the holding circuit as well. This will ensure the lift stops when it reaches your desired location. For Saftey purposes you may also add 2 additional limit switches for over travel which are tied into your Emergency Stop circuit. This is to protect you in case the normal limit switches malfunction and the lift doesn’t stop where it is supposed to, the over travel switch’s will trigger the Emergency Stop.

  • @kirubakaranRashmika
    @kirubakaranRashmika 3 года назад +1

    Superb ❤

  • @RGL642
    @RGL642 11 месяцев назад

    Would you be able to provide a parts list with PN's on what you used for this video. Thank you.

  • @TedWodoslawsky
    @TedWodoslawsky Год назад +3

    Good videos. However. those devices are not starters. they are contactors. A starter is a contactor plus and overload relay. When you added the overload relay, they became a starter.

  • @bricekokou7463
    @bricekokou7463 Год назад

    Hello sir thank you for everything how can I get all the components can you please send me the whole description of everything

  • @arnoldabadilla3291
    @arnoldabadilla3291 4 года назад

    Very Helpful Video! But could you make a video on Wye-Delta Motor Control Circuit with Forward and Reverse, Please!

  • @jesusacevedo2465
    @jesusacevedo2465 4 года назад

    Hello good video can you give the the list the parts you used I have project the same you do I’m confused 🤷‍♀️ thanks if can help

  • @lukestrange5501
    @lukestrange5501 4 года назад

    What kind of program do you use for the ladder diagram?

  • @KorisnikBr1
    @KorisnikBr1 Год назад +1

    Nice video but I think it's way easier to have 1-0-2 switch so you can't mix direction and it's really simple.
    I think this could be useful in bigger machines but then it's better to add PLC
    And I'm all about safety and working with live wires is not my thing.

  • @nilobue7857
    @nilobue7857 4 года назад

    Like video

  • @paulmanhart4481
    @paulmanhart4481 Год назад

    How does this work for a 130 vdc, 25 amp dc motor? I’d like a forward, stop, reverse buttons for this but I don’t know what I need or how to wire it. I’m using a 4.25 hp Leili treadmill motor.
    Thanks,
    Paul

  • @RGL642
    @RGL642 24 дня назад

    Hello, I have wired my 3 phase motor per your video and used same components best to my knoledge, the issue I'm having is when I turn on my 120v brkr it pops. I looked over everything a phew times and can't see what's wrong. Any ideas.
    Thank you for your time.

  • @jctai100
    @jctai100 Год назад

    I was wondering if you could do an updated video but more zoomed in to the motor starter to see the termination labels? Thanks

    • @AccessToPower
      @AccessToPower  Год назад +1

      I actually just filmed a new forward/reverse video and it should be done editing today. I will release the video on Tuesday next week.
      Thanks for your comments!

    • @jctai100
      @jctai100 Год назад

      @@AccessToPower My pleasure, your videos are very informative!

  • @lvnnurse1
    @lvnnurse1 3 года назад +1

    I wish you would provide links to purchase all of these components so that I could build my own set.

    • @jollyroger5147
      @jollyroger5147 3 года назад +1

      He is using products made by Eaton just google them and many electrical retailers sell them

  • @tinysand3517
    @tinysand3517 4 года назад

    HI Walter, what state do you live in? Offer any classes? Great presentation, would be nice if you can do a close up with interlock for the forward and reverse please

    • @AccessToPower
      @AccessToPower  4 года назад

      Young Pam we are in California. We currently offer classes to our employees but have just begun construction on what we hope will be a vocational training center

    • @tommyflyer5115
      @tommyflyer5115 3 года назад

      @@AccessToPower hello walter, which city in California? I hope your vocational classes is offer to outsiders and not just your employees, which I hope to joined in prospective.

  • @EKonMesh
    @EKonMesh 4 года назад +1

    I was wondering if you wanted to wire a indicator light when either starter is pulled in how you would do that in this situation?

    • @AccessToPower
      @AccessToPower  4 года назад

      good question. stay tuned ... in the next few videos we will add sequential starting. indicator lights on run and on fault, as well as timed start....

  • @romanusoduwole713
    @romanusoduwole713 2 года назад

    Do you give a hands on Training?

  • @RB-xv4si
    @RB-xv4si 4 года назад +1

    I think I would need to physically wire all of that myself to fully grasp the concept.

    • @salb714
      @salb714 3 года назад

      That is why being a adult and having money you can go buy this equipment and learn it at home or at work or business.

  • @niiayiteyaryee986
    @niiayiteyaryee986 4 года назад

    Can you tell us the name of the simulation software you used

  • @sarfrazally6575
    @sarfrazally6575 4 года назад

    How do you connect a110 volt where it’s 4 wire to the Motor

  • @top10trends59
    @top10trends59 3 года назад

    Can someone please tell me the software he is using for the simulations.

  • @tonyciarleglio8651
    @tonyciarleglio8651 4 года назад +1

    This system seems as if it would make a great dumb waiter set-up, how would you incorporate limit switches into this system? Fyi you have awesome teaching skills, very informative without going over doing it. Lmk thanks

    • @AccessToPower
      @AccessToPower  4 года назад +1

      Tony Ciarleglio
      This would work for a dumb waiter setup with the addition of 2 Normally Closed limit switches. If forward is up then I would place the top limit switch in line just before or after the existing NC “R” contact on the rung that powers the forward starter. When the waiter gets to the top the forward starter would loose power as the limit opens. You could then add a bottom NC limit just before the reverse starter coil to stop the waiter when it reached the bottom.

    • @tonyciarleglio8651
      @tonyciarleglio8651 4 года назад +1

      Thanks you're the best!

  • @johnocean5188
    @johnocean5188 Год назад +1

    did you do the control circuit wiring simulation on some kind of software, if so what is it?
    thanks a lot btw.

  • @aaronfidelisrecine
    @aaronfidelisrecine Год назад

    I have an old conveyor belt and it has a similar circuit to this BUT if the motor is spinning clockwise and you push the momentary switch to engage the counter clockwise position it auto cancels the other contactor and engages the other contactor. Do you have a video that explains this wiring?

    • @AccessToPower
      @AccessToPower  Год назад

      It sounds like you are missing the normally closed electrical interlocks.

    • @AccessToPower
      @AccessToPower  Год назад

      Grumman, I looked a bit more at your question and what is different about your forward/reversing setup is that your interlocks are not being controlled by a normally closed contact from the starters, but by normally closed contacts on the buttons. I am creating a video right now with the schematic on what is different and how to wire it. Thanks for the comment. I will send you a link to the new video when it is uploaded.

  • @butchlumansoc8427
    @butchlumansoc8427 2 года назад

    Sir you or your company sell a software or Cd that I can download to my computer so I can study while I'm on the ship. Thanks

  • @DarkKnight-ys1yg
    @DarkKnight-ys1yg 4 года назад +3

    Note: they a contactors (relays) not starters.

    • @kyliejoe91
      @kyliejoe91 4 года назад

      Please tell me the difference between a starter and a contactor

    • @jolyonwelsh9834
      @jolyonwelsh9834 4 года назад

      @@kyliejoe91 The only difference between a contactor and a starter is that there is an overload relay connected in series in line with the controlling contactor. This overload relay is what protects the motor from burn out if something goes wrong with the mechanical load such as a conveyor belt jamming or a bearing seizure. Some starters even have a phase loss feature which shuts off the motor if one of the phases is lost due to a storm for instance. This will also prevent motor burn out due to single phasing.

  • @hetasarvaiya6443
    @hetasarvaiya6443 2 месяца назад

    Motor control forward start yellow stop off reverse green switch power teacher ji

  • @ctbt1832
    @ctbt1832 7 месяцев назад

    This video is good but it would have been a whole lot better if he broke down where the wires are attached from and where they are coming from such as when he was installing the wires for the hold button so they will not be operating like a momentary button. He should also show the pieces and model numbers on the screen. But he should’ve broke down where each wire was coming from and where it’s going and zoomed in so people could see it. I would say he should remake this video and be more in detail.

  • @michaelkeith5178
    @michaelkeith5178 4 года назад +1

    Nice video But Demonstrating Proper PPE around live wires is also educational to others Due to arc fault and your NFPA 70e standards

  • @kennyporter7841
    @kennyporter7841 4 года назад

    Wheres your PPE

  • @irwinjimenez
    @irwinjimenez 4 года назад

    Don't you have change AB or BC to change direction? Changing AC will do nothing.

    • @AccessToPower
      @AccessToPower  4 года назад +3

      irwin jimenez , changing any 2 will reverse direction

  • @shamshadali7318
    @shamshadali7318 4 года назад

    Sir your videos very nice but you talking English Indian people need Hindi I love you working ❤️

  • @dallas5374
    @dallas5374 4 года назад

    Me confused 🙈

  • @lorchservice4366
    @lorchservice4366 4 года назад

    Where is mechanical interlock?

    • @AccessToPower
      @AccessToPower  4 года назад

      Lorch Service, I install it at the 1 minute mark and explain what it is.

  • @tnr6898
    @tnr6898 3 месяца назад

    You still need some electrical knowledge to understand this video. I know almost nothing and get lost after he adds the bridges. More detail on components is needed.

  • @georgenarso3148
    @georgenarso3148 4 года назад

    This isn't the right way to do a forward/reverse motor controls it does not meet IEEE standards of manufacturing nor it meets electrical trade industry requirement, further more it will be difficult to troubleshoot in case of failure.

    • @scottbustos819
      @scottbustos819 4 года назад

      -line protection this is exactly how its supposed to be wired. All equipment I work on comes wired this way straight from the manufacturer. You're telling me they dont follow the laws?

    • @georgenarso3148
      @georgenarso3148 4 года назад

      @@scottbustos819 Yes I am telling you that they not following IEEE

    • @BillFye
      @BillFye 3 года назад

      @@georgenarso3148 UL seems more prevalent in the industry.

  • @Loredo_1
    @Loredo_1 Год назад

    Dude you didn't explained where to wire your holding contact

  • @Loredo_1
    @Loredo_1 Год назад

    F*ck it looks so complicated 😫 😕 😩 and i got a practical next week.

  • @kirubakaranRashmika
    @kirubakaranRashmika 3 года назад

    Superb ❤