Hello, Dcs880/800 drive me ref voltage and ch.A+encoder feedback not match... please suggest how to set parameters to match the feedback and ref. Speed
Congratulations on the explanation. Would you be kind to explain to me: what is the field exciter? what happens if you reverse the field exciter wires? When I get error 515 field exciter, does it mean that I need to repair the motor? Thanks for the reply.
Hello sir hope you doinv well...i have dcs 800 dc drive s02-0025-05-0 As from data sheet it is 230vac to 525 Suorces volatges are 3 phase line 400.. I want to limit fileld volatges at 250 dc And armature voltages also at 250dc Thanks for your reply in advance
Make a video on dcs880 direction change
Practically full parameters setting ka video upload kijiye sir
Ok sir
Sir, can u make video about other dc drive like Parker, gemco splint, Siemens
I'll try.
Hello,
Dcs880/800 drive me ref voltage and ch.A+encoder feedback not match... please suggest how to set parameters to match the feedback and ref. Speed
I'll have to check sir. I'll revert ASAP
Fantastic overview explain
Thank you
hi
can you help me about commissioning cable and pinout or how to connect dcs800
thank you
I'll check and revert ASAP
Sir please make video on name plate of ACS 850 or Ac drive
Already available on my channel
Congratulations on the explanation.
Would you be kind to explain to me:
what is the field exciter?
what happens if you reverse the field exciter wires?
When I get error 515 field exciter, does it mean that I need to repair the motor?
Thanks for the reply.
Please give me some time. I'll check and revert ASAP
@@bishantkumar12589 OK
Sir ABB DCS 800 ka full detail ka video bnaye sir
Sure
Good explanation
TQ bhai
Is ki direction change kese Karen ge
Output DC hai. Isme direction ka issue nai hota hai.
Fantastic 👌👌
Tq
Hello sir hope you doinv well...i have dcs 800 dc drive s02-0025-05-0
As from data sheet it is 230vac to 525
Suorces volatges are 3 phase line 400..
I want to limit fileld volatges at 250 dc
And armature voltages also at 250dc
Thanks for your reply in advance
I'll check and reply sir. Pl wait
👌👌👌
Tq
SO1 means two quadrant
S02 means four quadrant
TQ sir
1 means what
1 - single bridge: 2-Q
Kirpa trable shooting bataya
Okay
@@bishantkumar12589 ,sugar lndustries batch type centrifugal machine
Aap ke phone number dijiye.kiyun ki mera life jo blind tha aaj bright hone ki ummeed aagaya hai
Bolo sir. How can I help
Mujhe DC drive ABB dcs 800 ke bare mein
@@chandrashekharjena729 okay I'll