Dixell XR60CX Controller full Parameter Details

Поделиться
HTML-код
  • Опубликовано: 20 окт 2024
  • Dixell XR60CX Controller full Parameter Details
    Cooling controller with defrosting management and fan control, HOT KEY, without sensor: The XR60CX is a device for front panel installation for normal and low temperature applications with three relay outputs for regulating the compressor, fan and defrosting process. These regulators have an NTC/PTC input for recording the room temperature as well as an evaporator sensor for defrosting. The regulator also stores the minimum and maximum temperatures. These can be viewed using the arrow keys. This device also features a configurable digital input. Easy programming via a “hot key”. The regulator has a TTL interface and is Modbus capable. These models can therefore also be connected to XWEB logging systems.
    More Parameters more safety for your machine.

Комментарии • 42

  • @manpritsinghsinghmanprit3257
    @manpritsinghsinghmanprit3257 5 месяцев назад +1

    Very good,, information and your way to teach is also very nice and easy

  • @ashokrawat9081
    @ashokrawat9081 Год назад +1

    आप sir बहुत ही अच्छे से हिंदी में समझा रहे है। प्लीज मैं चाहुंगा कि आप eliwel caral, danfus। और सभी पर विडियो बनाए।

  • @AsumujjuMujju
    @AsumujjuMujju 3 месяца назад +1

    Thank you sir thank you for everything very very helpful this video

  • @syedhussain8336
    @syedhussain8336 Год назад

    Bohath khoob Masha Allah

  • @Landeezy
    @Landeezy 6 месяцев назад

    how do i get to AC? Anti-short cycle delay? i know its in PR1. also to the OdS (Outputs activation delay at start up). im stuck at the Hy parameter

  • @ashokrawat9081
    @ashokrawat9081 Год назад +1

    Very nice sir 👍 thank

  • @bhavnapatel6476
    @bhavnapatel6476 4 месяца назад +1

    Good

  • @bhutiatenzi8816
    @bhutiatenzi8816 Год назад

    Thank you sir ❤

  • @macarthuralmuedajr541
    @macarthuralmuedajr541 Год назад +1

    How to change defrost setting?? My open chiller not stop compressor. Thanks

  • @mahendrayadav8408
    @mahendrayadav8408 Год назад +1

    Very nice 👍

    • @syedhussain8336
      @syedhussain8336 Год назад

      I have 3 door reaching freezer model S-72 F some time temperature goes 20 -30F I think of parameter setting please advise thanks

  • @greenland2166
    @greenland2166 11 месяцев назад +1

    Bro... Compressor running but defrost sign alwways blinking why.. How to reset

    • @uniquetechnicalservice
      @uniquetechnicalservice  11 месяцев назад +2

      Defrost sign blinking means it's Dripping time . Change the Fdt parameter set 2mintus.

    • @greenland2166
      @greenland2166 11 месяцев назад

      @@uniquetechnicalservice sir plese give me whatsapp number
      . Im here with unit.. I need to fix this now...plses help me

  • @syedfazaljajnerysheikhpurw5676

    Freezer on kartye hi compressor and upper fan on ho jata hai
    2 ya 3 minutes ka delay karna hai

  • @mohammedsyedali8438
    @mohammedsyedali8438 Месяц назад +1

    Wat. Is ptc. Wat is ntc

  • @shibumon4066
    @shibumon4066 Год назад

    When start the controler solinod is blinking.. What is the reason and how to fix this problem

  • @shibumon4066
    @shibumon4066 Год назад +1

    How to activated fan.. Digital is Showing only compressor

    • @uniquetechnicalservice
      @uniquetechnicalservice  Год назад

      In Fnc folder select O N setting.

    • @shibumon4066
      @shibumon4066 Год назад +1

      For freezer which mode need?

    • @uniquetechnicalservice
      @uniquetechnicalservice  Год назад

      O N is better for freezer allso. Need air circulation in all the time and defrosting time fan will be in off condition.

    • @shibumon4066
      @shibumon4066 Год назад +1

      But this mode fan not activated in digital

    • @uniquetechnicalservice
      @uniquetechnicalservice  Год назад

      Ok then can you check FST set point. Fst means fan stop temperature. Increase that set point above 30 Degree

  • @ravisankar8383
    @ravisankar8383 Год назад +1

    Showing H2 erorr ...what is the reason

  • @naushadmohammad2784
    @naushadmohammad2784 2 месяца назад

    Modebus mapping

  • @kalim162
    @kalim162 Год назад +1

    Fen aaor hitr dono chalo krna hi

  • @arjunapeiris981
    @arjunapeiris981 7 месяцев назад +1

    Nice can make one vedio carel thermastat if you give your mail I'd or whats up number. I will send carel model