How to Properly Enable Solis Grid Tie Limiter Function

Поделиться
HTML-код
  • Опубликовано: 1 июн 2021
  • This video shows you how to prepare your Solis Grid Tie limiter functions enabled. What to do properly prior to activating your limiting functions on your Grid Tie.
  • ХоббиХобби

Комментарии • 191

  • @anakngjurassik
    @anakngjurassik 3 года назад +2

    Ayos to ka solar magandang info ito..stay safe

  • @allanbarge69
    @allanbarge69 2 года назад +1

    Thanks for the video

  • @benkanobe7500
    @benkanobe7500 5 месяцев назад

    Thank you for attempting this RUclips. I had my computer lap top turned to Max Volume and I could barely hear you. I do not think that was a simple set up and you seemed confused as to what to press next. Also, what was all the "Waiting"? I am looking to replace my Sun blue box 1000Watt Grid Tie Inverters with limiters, but this demonstration did not convince me this is any better. Can you recommend another RUclips on this subject with Solis Inverter? Thank you, it sure looks like a nice inverter.

    • @MarkMinoza
      @MarkMinoza  5 месяцев назад

      Thats "Waiting" to sync to the Grid for 10 minutes as a requirement by the local DU.

  • @CB27
    @CB27 Год назад +3

    Thank you for making this video.
    I have a 4G 5kW Solis inverter. Recently it started showing a hint alarm "Grid over voltage". How do I adjust the setting to stop the alarm. The grid is 238V, so not over voltage (240V system).

    • @MarkMinoza
      @MarkMinoza  Год назад +1

      you can change its Grid Standard to UL-240. Any voltages that goes beyond 235Vac, UL-240 is being used and stable.

  • @johnruben1444
    @johnruben1444 9 месяцев назад

    Very informative video, thank you very much. I have done the same setup and also limited export to -00000w (negative) since I do not have net metering from electricity company. The issue is throughout the day my minimum load is around 250-300watts due to my home UPS/inverter but LimByEPM generates around 160watts and limits the rest, when I turon on geyser then it generates more and delivers 2000w to 2600watts for the geyser, but when i switch off the geyser, it is back to 160-180watts and not generating full required load, why is this happening and I have the same CT and my solis inverter is S6 3kw with 540w x 6 mono perc panels. Pls help if further setting is needed to maximize my load. Also should I change my CT sampling ratio ?

    • @MarkMinoza
      @MarkMinoza  9 месяцев назад

      Don't change your CT ratio if it's working. Though I upgraded my 3kw Solis meter type. I only observe that if my PV voltage drops to 200v. Check your graphs for confirmation.

    • @johnruben1444
      @johnruben1444 9 месяцев назад

      @@MarkMinoza my PV voltage doesn't drop, most of the time I see PV being above 220+ and inverter only controls the amp. My graphs are usually up and down. What if I change export to +100w ? But I am scared my electricity bill will shoot up as mine is not a bi-directional meter.

    • @MarkMinoza
      @MarkMinoza  9 месяцев назад

      @@johnruben1444 you may consult your local support. your inverter might need a firmware upgrade.

  • @rickyrusselburgusa8644
    @rickyrusselburgusa8644 6 месяцев назад

    Hey Mark, great video. So if you had to do over again, would you still go with the salmon burgers?

  • @ramkumarsharma4139
    @ramkumarsharma4139 2 года назад

    What means power in watts in lcd schreen.it is generating by panels or going to household out appliances?

    • @MarkMinoza
      @MarkMinoza  2 года назад

      It's generating power going to the grid, not household. Its your grid that powers your appliances in your house loads.

  • @markgensiquian5399
    @markgensiquian5399 3 года назад +1

    ty bossing

  • @TubolMotoadventures
    @TubolMotoadventures Год назад +1

    What do u mean by make sure the load is above 500w? You mean the limiter wont work if the load is below 500w? so 300 watts will be just all be coming from the grid because it is below 500?

    • @MarkMinoza
      @MarkMinoza  Год назад +1

      You current load (watts) should be above 500w for the limiter to be activated. The CT will detect who big is your power during the CT Link test.

  • @raffy323232
    @raffy323232 3 года назад +1

    good and informative video.... just want to ask kung talagang matagal talaga yung "status"... napansin ko... from 9:06am.... nag start and mga around 12:30pm na nag start mag produce ng around 630 watts at nag start na mag configure ng settings

    • @MarkMinoza
      @MarkMinoza  3 года назад +1

      Ang explanation ko sir sa video is to have the grid tie first get its maximum generation. This is to validate that we have no issue sa output ng gti bago e limit. Kasi pag nag limit kaagad tayo din hindi natin nakuha ang peak generation, ang usual question ng mga user palaging, baba ng harvest ko. I hope I answer your inquiry right.

  • @SoLuna137
    @SoLuna137 Год назад

    how does Meter in Load work? does it mean that the CT is placed in the Load side of facility?

    • @MarkMinoza
      @MarkMinoza  Год назад

      Meter in Load connection depends on the type of meter you’re using, I’ve placed a reference link below. But the way it works, think of it like connecting a sub meter to other connection. The meter is placed between source and Load. DU setup is meter in Load. Accuracy is high also in terms of reading.
      ruclips.net/video/XalI0hPni3o/видео.html ,

  • @emydg.9872
    @emydg.9872 Год назад

    sir what is the procedure when shutting down the inverter? Which breaker to turn off first?

    • @MarkMinoza
      @MarkMinoza  Год назад

      If its running, do the following steps.
      1. Disconnect your Grid
      2. Disconnect your PV

  • @seans5960
    @seans5960 Год назад +1

    I have this inverter and a second 6kw hybrid 5G (with the meter) - but it’s exporting far greater than the backflow limit, it’s like the hybrid can’t “see” what the non hybrid 4g is exporting- any suggestions? The address on both inverters is 01, is that correct?
    Thank you 🙏

    • @MarkMinoza
      @MarkMinoza  Год назад

      Are you trying to limit the production? If you do. Enable. The limiter on Hybrid, have the GTi lower rating do all the harvest.
      What meter are you using in your Hybrid?

    • @seans5960
      @seans5960 Год назад

      No, I want to limit exporting -EPM. The meter is RS485, the model is Acrel ACR10R.
      If I set the backflow to zero, the hybrid stops exporting but the 4g inverter keeps exporting

    • @MarkMinoza
      @MarkMinoza  Год назад

      @@seans5960 then enable limiter on the 4G GTi. Regardless if its a ct or meter.

  • @oshinaguilar
    @oshinaguilar 2 года назад +2

    The sequence of Commissioning; 1. start the Inverter ON; 2. AC breaker ON; 3. DC Breaker On? Correct po?

    • @MarkMinoza
      @MarkMinoza  2 года назад +1

      1. Enable the Grid first
      2. Enable your PV side ON
      Regardless anong gamit nyo na safety device (disconnect switch or MCB) , importante may pang disconnect kayo ng supply (PV or Grid). Iba naman gamit fuses.

    • @oshinaguilar
      @oshinaguilar 2 года назад

      @@MarkMinoza when will be the inverter turn ON? before or after GRID & PV turned on? salamat po.

    • @MarkMinoza
      @MarkMinoza  2 года назад +1

      @@oshinaguilar it will turn on Only when your PV has reach its MPPT startup voltage (check your data sheet) . Depende sa wattage nyo, 3kw - 8kw Solis has 120Vdc startup while lower ratings has 90v and 60v.

  • @kmb123999
    @kmb123999 Год назад

    May I ask, what specification of Solar Panels for 1kw Solis GTI S6 model. Thank you

    • @MarkMinoza
      @MarkMinoza  Год назад +1

      my setup is having a 100w x 12. GTi on the video is 4G Model, not yet S6.

    • @kmb123999
      @kmb123999 Год назад +1

      Thanks sir Mark :D

  • @ryanvarona730
    @ryanvarona730 Год назад

    sir, once mulang e set/enable yung limiter? or do you have to enable it everyday?

    • @MarkMinoza
      @MarkMinoza  Год назад

      once lang sir, the system will automatically save it.

  • @luisreyes2546
    @luisreyes2546 Год назад

    What is your pv connections? I have 4pcs pv panels 250w @34.1Voc each, what connections do I do?

    • @MarkMinoza
      @MarkMinoza  Год назад

      Have it all in series. What I have is 12 x 100w all in series. Vdc startup is at 60v. So your 4 pv is perfect.

    • @luisreyes2546
      @luisreyes2546 Год назад

      @@MarkMinoza Done, sir all 4 in series. And it's generating power. Thank you

  • @wolfgangcorrea7878
    @wolfgangcorrea7878 8 месяцев назад

    Hi, When CT is 100:33mA .. sample ratio should be 3000:1 I guess. But i see a lot of people recommending 1500:1. Why is it?

    • @MarkMinoza
      @MarkMinoza  8 месяцев назад

      That's the standard value using the specific CT provided by Solis. No idea why some.people would have more than 3000:1 ratio.

  • @MrJeonard1985
    @MrJeonard1985 Месяц назад

    can i series 2 unit s6 5kw gridtie? if yes how connect the ct

    • @MarkMinoza
      @MarkMinoza  Месяц назад

      yes, CT can be placed on both Active Line wire. if more than 2 in parallel, you need EPM for that.

  • @ramkumarsharma4139
    @ramkumarsharma4139 2 года назад

    Sir good morning pl solve my problem.as in my house 3 phase Solis inverter and in one or 2 phases from 12 noon to 3.00 pm voltage comes from 170 to 195 Can we with yr kind help limit the minimum input voltage to reqd level to run the inverter without alarm and produce electricity.sir what is min voltage reqd to run inverter smoothly or we can set / modify the range as minimum under un- g- v01 or v02. Pl advise me or any other solution.pl

    • @MarkMinoza
      @MarkMinoza  2 года назад

      Hi Ram, User Define is country specific. Values might be different ours. If its low grid voltage, choose UL-208 grid standard.

    • @ramkumarsharma4139
      @ramkumarsharma4139 2 года назад

      @@MarkMinoza sir by this option problem will be solved because after 3 to 4 pm grid voltage reaches above 200 .so pl give yr mob no to chat and solve the problem.

    • @MarkMinoza
      @MarkMinoza  2 года назад

      @@ramkumarsharma4139 have you tried contacting your local support? You can choose the User Define Options, I'll. Be making that video on the coming days to address your concern.

    • @ramkumarsharma4139
      @ramkumarsharma4139 2 года назад

      @@MarkMinoza sir It is possible to make / modify limit coming from grid as such 170 to 195 during hot sunny time when solar produces optimistic valuable energy to max and it's use in real sense sir.Can I talk to yourself when Co man comes today most peobly and he will set the lower limit of grid voltage as required to run the 3 phase inverter smoothly sir.or we have to change single phase Solis inverter sir pl

    • @MarkMinoza
      @MarkMinoza  2 года назад

      @@ramkumarsharma4139 you can configure it. V1/V2 is youre threshold values.

  • @francisjunsay39
    @francisjunsay39 2 года назад +1

    boss baka may video ka paano magconfigure ng energy meter via rs485 zero export

    • @MarkMinoza
      @MarkMinoza  2 года назад

      Need nyo po API ng hardware to be able to do that. Solis supports modbus protocol running on rs485 using A B connection. External Energy meter is like the EPM. Please see my EPM unboxing vid, may pin config po doon.

  • @romelnungay7776
    @romelnungay7776 Год назад

    Does LimByEPM status means that my export control is off or on?

  • @ramkumarsharma4139
    @ramkumarsharma4139 2 года назад

    335 watt 15 panels sir

  • @kamalhussain8517
    @kamalhussain8517 3 года назад

    How can I buy one of these

    • @MarkMinoza
      @MarkMinoza  3 года назад

      Depending where you are, Solis is available worldwide. You may reach them thru this site. www.solisinverters.com . If you live in PH, Lazada or Shopee online portal has one.

  • @murattan3865
    @murattan3865 2 года назад +1

    Is a smart meter necessary? Is just ct enough?

    • @MarkMinoza
      @MarkMinoza  2 года назад +1

      Depending on the GTi type, this one is CT. Solis also has Meter type GTi, you need to ask it from your seller.

  • @franklaurencecanoy617
    @franklaurencecanoy617 3 года назад

    Nice vid. hi sir may alam po bakayung model ng solis inverter 4kw, na may export limiter ?

    • @MarkMinoza
      @MarkMinoza  3 года назад +1

      1/3/5/6/8/10kw lahat po may limiter functions. Ask your seller to include one.

    • @franklaurencecanoy617
      @franklaurencecanoy617 3 года назад

      @@MarkMinoza thank you po, Pano po ba malaman na may export limiter siya sir? may ibang name ho ba cya na it means this inverter is has export limiter ? kasi sa data sheet d ko makita yung exact word na export limiter, pa help po

    • @MarkMinoza
      @MarkMinoza  3 года назад

      @@franklaurencecanoy617 check your serial #, on the 6th digit, it should be 1 or 2, 1= ct, 2=meter. Pag 0, hindi activated ang limiting functions. Bili ka ng external EPM para mag function ang limiter.
      SN# 123A45 1

  • @andyronan1202
    @andyronan1202 2 года назад +1

    OMG you have just fried my brain,

  • @ramkumarsharma4139
    @ramkumarsharma4139 2 года назад

    In my single phase inverter status shows LIM By Vg normally in midday 12 to 3 pm when grid voltage show 270+ and oneby one some time generating and limbyvg Is It harmful to inverter and vice versa how to rectify this problem sir.pl

    • @MarkMinoza
      @MarkMinoza  2 года назад

      What's the model of your Inverter and its max PV installed?

    • @ramkumarsharma4139
      @ramkumarsharma4139 2 года назад

      @@MarkMinoza Solis inverter single phase 1P 5 k 4 G and panels 15 for 5 KW sir

    • @MarkMinoza
      @MarkMinoza  2 года назад

      @@ramkumarsharma4139 can you provide the break down of your PV String, how many are in DC1 , DC2 and DC3 in series ?

    • @ramkumarsharma4139
      @ramkumarsharma4139 2 года назад

      @@MarkMinoza in DC1 seven panels and DC2 8 panels .normally in DC1 status shows approx 230 or 240 and in DC2 shows above 250 to 270 in mid day time sir

    • @MarkMinoza
      @MarkMinoza  2 года назад

      @@ramkumarsharma4139 your pv setup is correct, the alert on LimbyVg is has something to do with power generation. The inverter limits its power generation during that time. Check your Advance Information page for more details or your SolisCloud Portal.

  • @anethemia7857
    @anethemia7857 2 года назад

    Sir mark yung linya namin dito sa cebu province is line to line,saan po dapat elagay yung ct sensor sir?

    • @MarkMinoza
      @MarkMinoza  2 года назад

      Either side since kung.L-L.

  • @sofiakulittv4880
    @sofiakulittv4880 2 года назад

    Good day sir....ok lang ba pag LimByEPM yung nsa satatus nya?....tnx you po

    • @MarkMinoza
      @MarkMinoza  2 года назад

      Yes po, that means the limiter is enabled.

  • @ranelmaglangit
    @ranelmaglangit 3 года назад

    sir mark panu po ba yung hybrid ko??6kw sya..tapos 1 to 2 kw lng na haharvest nya..wala pang battery...den naka limiter ako

    • @MarkMinoza
      @MarkMinoza  3 года назад

      Remove the limiter para malaman nyo sir ang max output. Install also the soliscloud app. Nakikita mo kasi lahat doon ang consumption nyo vs generation kung tama. Maganda ang graph ni Solis sa portal, puede kang mamimili ng data.

  • @anuledsroma
    @anuledsroma Год назад

    Hello Mark, gusto kong mag-ADD ng isa pang SOLIS inverter, i am using SOLIS-1P5K-4G at naka net-metering na, problem kulang na yung 5K sa akin. need more, can Solis be paralleled connection tho net metering?
    Salamat po. God bless po
    Paano po yung electrical wiring diagram?

    • @MarkMinoza
      @MarkMinoza  Год назад

      Yes, no issue on parallel if its net metered. Buy the Meter type GTi S6 models. Just like your existing, just add it to a new branch circuit.

  • @anethemia7857
    @anethemia7857 2 года назад

    may 2kw bah nah solis sir?

  • @richardalegre9881
    @richardalegre9881 Год назад

    Goodmorning sir, mag tatanong lang po ako about sa export control sir ng Solis, lalabas lang po ba yung status po na "LimByEPM" pag sobra napo yung ginegenarate po kesa sa load ng building po?

    • @MarkMinoza
      @MarkMinoza  Год назад +1

      Yes sir, lalabas yan. pag nag hahabol at it will have Generating display. 1Kw output, pero ang load is 2Kw, Generating ang lcd nyo.

    • @richardalegre9881
      @richardalegre9881 Год назад +1

      @@MarkMinoza Maraming salamat Sir!

  • @hawkray77
    @hawkray77 5 месяцев назад

    sir new user ako ng solis s6 gr1p6k s, pwede po ba magparuro pano set-up ang limiter nito? salamat po

    • @MarkMinoza
      @MarkMinoza  5 месяцев назад

      Sa Model S, wala pa akong guide, ill make one. kaka kuha ko palang ng unit.

  • @anethemia7857
    @anethemia7857 2 года назад

    Sir good day po,alwys watchng from cebu prvince.sir mark kung mag install ng sOLis ano una dapat esettings sah parameters sir?.

    • @MarkMinoza
      @MarkMinoza  2 года назад +1

      kung similar hardware na Grid Tie inverter (Solis), this YT is your guide to enable the Inverter not to export.

    • @anethemia7857
      @anethemia7857 2 года назад

      @@MarkMinoza sir mark hindi bah masira ang solis inverter kung sakali ang load ng aking bahay ay aabot ng 5kw,tapos yung sOLis invrtr koh ay 3kw lng sir?

    • @MarkMinoza
      @MarkMinoza  2 года назад +1

      @@anethemia7857 Hindi po since its a Grid Tie Inverter, walang issue sa overload since regardless of load, sa Grid siya nag send ng power, not to your load.

    • @anethemia7857
      @anethemia7857 2 года назад +1

      @@MarkMinoza ok thank u sir.

  • @RandyNicolas-mu9wp
    @RandyNicolas-mu9wp Год назад

    Sir, saan puede bumili ng current sensor para sa 6k s6 ct type. Thank you sor Mark.

  • @reggieanuta675
    @reggieanuta675 2 года назад

    Sir..paano po ba ang tamang paglagay ng limiter..
    1.Dapat ba malapit sa main panel box ng bahay?
    2.Ano po ang position ng arrow..Papunta ba sa main panel box?

    • @MarkMinoza
      @MarkMinoza  2 года назад +1

      1. Hindi po kailangan since ang CT lang dapat malapit sa main breaker
      2. Nasa video po paano malaman kung tama ang ang link. Dapat e test mismo.

  • @murattan3865
    @murattan3865 2 года назад

    CT connect ?

    • @MarkMinoza
      @MarkMinoza  2 года назад +1

      Connect your CT to your main line, before the Load.

  • @muhammadhilmiyusra8932
    @muhammadhilmiyusra8932 2 года назад

    This solis 1kw or 3kw?

    • @MarkMinoza
      @MarkMinoza  2 года назад

      the procedure works on any Single Phase Solis units. Im using a 1Kw GTi on this video

    • @muhammadhilmiyusra8932
      @muhammadhilmiyusra8932 2 года назад +1

      can you make a video for the installation from beginning like how to install solar panel to inverter and grid from electric home. Thankyou sir because i wanna make solar grid tie in my home.

    • @MarkMinoza
      @MarkMinoza  2 года назад

      @@muhammadhilmiyusra8932 you might want to see this past video using micro GTi i did. Ill create one in the future. you can drop me an email and ill be happy to help you.
      ruclips.net/video/dqj1wfxc-kY/видео.html

  • @maymay1382
    @maymay1382 2 года назад

    Sir paano gamitin ang user define kc laging nag highvoltage s amin kaya nagkulay orange si inverter gusto k sanang iadjust voltage range ng solis 3kw na gamit kp. Tnx po sana maituro niyo po.

    • @MarkMinoza
      @MarkMinoza  2 года назад

      User Define is based on your Grid provider. Sila ang mag bibigay sa inyo nyan. Ill come up with a guide on that also dahil marami ding nag tatanong. But if your grid is high, use the UL-240 settings.

    • @maymay1382
      @maymay1382 2 года назад +1

      @@MarkMinoza tnx po. Try ko po, aabot kc ng 242 - 246volts ang grid namin kaya lging alarm pag sa tanghali lng nman.

  • @kentoy5598
    @kentoy5598 3 года назад

    Good day, Bakit kaya sir yung solis 3kW inverter ko kapag e on na yung transformer type na welding machine sa grid sya kumukuha ng power?

    • @MarkMinoza
      @MarkMinoza  3 года назад

      Sa grid po lahat, since your gti is connected sa grid. Mag depende naman po yan sa generation ng gti nyo during usage ng welding nyo. Malakas ang welding.

    • @kentoy5598
      @kentoy5598 3 года назад

      @@MarkMinoza Kasi pag nka on na yung welding machine may 8 amps reading ang clamp meter sa grid na side then 300 watts sa inverter. Papalo ng 1kW mahigit genereated power sa inverter kapag mag wewelding na. Sa grid side nman aabot ng 10 Amps. Gusto ko sana pag nka standby yung welding machine sa inverter sya kukuha ng power mara masagad yung harvest.

    • @MarkMinoza
      @MarkMinoza  3 года назад

      @@kentoy5598 the Inverter cannot react automatically sa surge ng welding nyo po. Also, kung naka limiter kayo, talo pag may welding kayo. To get your current ng inverter nyo, but a clamp meter with inrush capability. Para makita nyo gaano kalaki ang lumalabas na current during welding.

  • @raymundzacarias834
    @raymundzacarias834 3 года назад

    bakit ung sakin naka set nmn na ung ct at correct nmn pero bakit pag nagbawas na aq ng load sa bahay eh nag exxport aq sa meralco, any tips? ung linya nmin d2 110v-0-110v khit sa kabilang linya same parin nag eexport parin aq.. baka pd nyo aq matulungan sa issue q salamat po

    • @MarkMinoza
      @MarkMinoza  3 года назад

      Split phase ba ang 220v nyo ?

  • @boymakul8vlogs363
    @boymakul8vlogs363 2 года назад

    Ask lng po paano kung na install na lahat tapos ang power lang is 30w ang nasa display ano po gagawin

    • @MarkMinoza
      @MarkMinoza  2 года назад

      dont enable the limiter muna. Just like in my video, pina takbo ko muna para makita ko ang peak harvest then doon pa ako nag enable ng limiter. Now, ang pag lagay sa CT mag depende sa Grid type nyo. Pag L-L no issue, pag L-N, sa L nyo ikabit.

  • @ejjuan9220
    @ejjuan9220 3 года назад

    Kahit po ba to connected sa grid, di sya mag oon hangga't walang power si panel?

    • @MarkMinoza
      @MarkMinoza  3 года назад

      Yes po, the gti will shutdown without PV

  • @bibsky222
    @bibsky222 2 года назад

    sir may paraan ba para ma zero limit ang grid. kc kahit mganda naman harvest ay may 70 to 80 watts pang consume sa grid.

    • @MarkMinoza
      @MarkMinoza  2 года назад +1

      Ang limiter nyo po nag aadjust lagi sa load nyo. Either mahuli o mauna. Hindi talaga ma 0 yan unless ang load nyo constant, hindi gumagalaw. Kung 100w, 100w lang talaga, pero hindi yan mangyayari dahil ang mga gamit natin pabago bago.

    • @bibsky222
      @bibsky222 2 года назад

      @@MarkMinoza k salamat sir. nkita ko kc solax 0 and 5 lng lagi yung makikita mong cobsumed load s metro. maliban lng kung mababa harvest. yung sakin solis 1 kilowatt pv ang max load ko lng ay 300 watts . pansin ko kahit tirik araw more or less 700 watts na ang harvest pero mataas pa din yung load s metro bka may mali ako sa settings.

    • @MarkMinoza
      @MarkMinoza  2 года назад

      @@bibsky222 nakikita ko sa 3kw ko na mag 0 using may external digital watt meter sa bahay. Ang 1kw ko pang test lang so hindi ko na test properly. Ill test again.

    • @KutsiTekin
      @KutsiTekin 2 года назад

      İnverter devredeyken gücüne göre şebeke enerjisini sıfır tüketen cihaz bakıyorum tavsiyeniz varmı ?

    • @jasonking4697
      @jasonking4697 3 месяца назад

      Set mo lng backflow power from 0 to 100 watts ma zero yn lalo n pag malakas harvest vs load

  • @anethemia7857
    @anethemia7857 2 года назад

    Kung magset up ng grid tie sir,kaelangan paba magpaalam sah DU Sir mark?

    • @MarkMinoza
      @MarkMinoza  2 года назад +1

      not necessarily since On Grid po, sa umaga lang libre. kung gusto mong putulin si DU, mag Hybrid Off Grid ka. though mahal dahil sa battery.

    • @anethemia7857
      @anethemia7857 2 года назад +1

      @@MarkMinoza ok po sir,maraming slmat sayo.

    • @anethemia7857
      @anethemia7857 2 года назад

      @@MarkMinoza yung CT sensor sir,kasya bah sya eclamp sah stranded wire nah ang sukat ay 25mm or 35mm sir?

    • @MarkMinoza
      @MarkMinoza  2 года назад

      @@anethemia7857 Kasya pa sa 25mm (4awg) sa 35mm mukhang hindi na mag kasya.

  • @lopin-nh2oy
    @lopin-nh2oy 7 дней назад

    SIR KASAMA BA CT LIMITER SA PACKAGE NG SOLIS INVERTER? OR NEED KO PA BUMILI SEPARATE

    • @MarkMinoza
      @MarkMinoza  6 дней назад

      @@lopin-nh2oy alam ko kasama, but ask bago bumili just to make sure.

  • @ruelebio8179
    @ruelebio8179 Год назад

    Puede ba yan i set na off grid lng?

    • @MarkMinoza
      @MarkMinoza  Год назад

      Grid Tie Inverter po yan, hindi po yan tatakbo na walang grid. Need nyo po is off grid Inverter or hybrid off grid inverter para magamit nyo ang hardware kahit walang grid ang lugar nyo.

  • @pierduos2099
    @pierduos2099 2 года назад

    Good day sir baka pwd po pahelp .. panuka namin makontak gusto lang po namen magpa assist. Sa solar set up namin?

    • @MarkMinoza
      @MarkMinoza  2 года назад

      You may ask for Solis Support from the FB Group here.
      facebook.com/groups/413473389645478/?ref=share_group_link

  • @diyaccesories7788
    @diyaccesories7788 4 месяца назад

    Every morning po ba need to set the limiter kapag ng power on na inverter?

    • @MarkMinoza
      @MarkMinoza  4 месяца назад

      once lang yan sir e set. then activated na.

    • @diyaccesories7788
      @diyaccesories7788 4 месяца назад

      @@MarkMinoza how about load sir kahit bellow 500w example umalis ako maga at 200 watts lang maghapon nakaactivate pa din po limiter nun? Worry ako kc baka magexport sa DU. TNX PO

    • @MarkMinoza
      @MarkMinoza  4 месяца назад

      @@diyaccesories7788 regardless, once ma set ang limiter, activated na po yan kahit gaano kaliit ang load.

  • @shaagaelecp6musicmadhushan795
    @shaagaelecp6musicmadhushan795 Год назад

    sound is very low. 😪

  • @marigoldkitchenette6103
    @marigoldkitchenette6103 3 года назад

    Magandang araw po sir 3k Solis inverter po ung gamit ko.bkit po kya pag binubuksan ko ung aircon nag aalarm ung inverter ko.salamat po

    • @MarkMinoza
      @MarkMinoza  3 года назад

      Paanong alarm? Baka puedeng ma share mo ang alarm code or description.

    • @marigoldkitchenette6103
      @marigoldkitchenette6103 3 года назад

      Ung monitor po nya sir naka kulay orange.tsk bkit po ung export ay sobrang laki ng nilalabas? salamat po sir sa pag bigay nyo ng pansin

    • @marigoldkitchenette6103
      @marigoldkitchenette6103 3 года назад

      @@MarkMinoza hnd po ako marunong mag insert photo sa youtube

    • @marigoldkitchenette6103
      @marigoldkitchenette6103 3 года назад

      @@MarkMinoza sir may contact No.po b kyo para kyo n lng irecomend ko sa kaibigan ko

    • @marigoldkitchenette6103
      @marigoldkitchenette6103 3 года назад

      Hnd po kya dahil pag malaki ang Load umiinit ung inverter kya nag aauto shot down?ok lng po kya sir lagyan ng cooling fan?

  • @anethemia7857
    @anethemia7857 2 года назад

    Good po sir mark,magkano ang 2kw solis sir?

    • @MarkMinoza
      @MarkMinoza  2 года назад

      sa OnePoint ko eto nabili, 1Kw and 3.6Kw ang available sa kanila. 12K bili ko sa 1Kw ko. 27K ang 3.6Kw nila

    • @anethemia7857
      @anethemia7857 2 года назад

      @@MarkMinoza yung output ng solis invrtr sir mark,saan dapat elagay sir sah input ng main breakr ng bahay sir?.

    • @anethemia7857
      @anethemia7857 2 года назад

      @@MarkMinoza maraming slmat sah mga sagot moh sir,alwys watchng ur vedios from cebu province.

  • @marigoldkitchenette6103
    @marigoldkitchenette6103 2 года назад

    Sir ano po ibig sabihin ng limbyVar. Salamat po

    • @MarkMinoza
      @MarkMinoza  2 года назад

      Not familiar by it. You may escalate it to support.

  • @fireandrevivalinmyheart6365
    @fireandrevivalinmyheart6365 2 года назад

    Hi po boss pano po mg install ng 30kw grid tie po na solis grid tied po diko po alam yung pag parallel nga solar panel po hehehe ng try lng mg design sir... hehehe

    • @MarkMinoza
      @MarkMinoza  2 года назад

      need nyo po EPM for that huge capacity. ang EPM may manual, nandoon ang design paano nyo e parallel ang connection.

    • @fireandrevivalinmyheart6365
      @fireandrevivalinmyheart6365 2 года назад +1

      @@MarkMinoza salamat po bossing try ko e search duon..thanks

    • @MarkMinoza
      @MarkMinoza  2 года назад

      @@fireandrevivalinmyheart6365 sali ka po sa PH Solis Group, may local support naman yan. facebook.com/groups/413473389645478/?ref=share

  • @alaehcjsvlog
    @alaehcjsvlog 2 года назад

    boss tanung lang po about sa ct pano po gagawin dun naka saksak naman po sya pero wala sya sa settings po walang mode select at ct sampling ratio wala po sa setting solis 3kw din po gamit ko

    • @MarkMinoza
      @MarkMinoza  2 года назад

      Napasok nyo po ba ang “Advanced Settings” ng unit nyo?

    • @alaehcjsvlog
      @alaehcjsvlog 2 года назад

      @@MarkMinoza opo wala nga po dun

    • @alaehcjsvlog
      @alaehcjsvlog 2 года назад

      @@MarkMinoza wala po sya sa advance settings

    • @alaehcjsvlog
      @alaehcjsvlog 2 года назад

      @@MarkMinoza na reset and update kona din po sya wala parin po

    • @MarkMinoza
      @MarkMinoza  2 года назад

      @@alaehcjsvlog anong model ng unit nyo?

  • @aldeebigueja9609
    @aldeebigueja9609 Год назад

    sir yun arrow ng limiter papalabas ba ng grid or papasok, sa video kc papalabas pero binago nyo. tnx

    • @MarkMinoza
      @MarkMinoza  Год назад

      Yung CT link Test po ang susundin nyo kung saang arrow. Hindi nyo ma activate ang limiter kung hindi kayo mag CT link sa CT type Inverter. Sa meter no need, ill post a new video using meter.

    • @aldeebigueja9609
      @aldeebigueja9609 Год назад

      @@MarkMinoza sir mark m ano ibig sabihin ng fail safe sa gti

    • @MarkMinoza
      @MarkMinoza  Год назад

      @@aldeebigueja9609 you can enable Fail Safe or Not, hindi requirement sa atin yan. Ang trabaho ng failsafe is to check the connection ng CT at Inverter. Pag nawala or open ang ct mo, mag alarm.

    • @aldeebigueja9609
      @aldeebigueja9609 Год назад

      ​@@MarkMinoza sir bakit kaya 11w lang na generate ng gti ko 4x240w pv ko tnx

    • @MarkMinoza
      @MarkMinoza  Год назад

      @@aldeebigueja9609 anong Vmp ng pv nyo at rating ng Solis Inverter na Ginamit? Disable nyo muna ang limiter para ma check ang max output.

  • @markgilder9990
    @markgilder9990 2 года назад

    About as clear as mud.

  • @werdem
    @werdem 2 года назад

    mali ata. nag ON nang EPM pero Generating parin. dapat LimByEPM. mag babayad ka sa meralco nya. dagdag load

    • @MarkMinoza
      @MarkMinoza  2 года назад +1

      Half of the vid po ata ang nakita nyo, or you skip it. 8:15 timeline ang limbyepm.

    • @werdem
      @werdem 2 года назад +1

      @@MarkMinoza tama. hnd ko nakita limbyepm.

    • @MarkMinoza
      @MarkMinoza  2 года назад

      @@werdem pina generate ko muna para makita ko ang Peak harvest before enabling the limiter. Kasi pag enable nyo kaagad, palaging tanong ng iba, bakit ang baba ng harvest?

  • @llewellynala6807
    @llewellynala6807 3 года назад

    Sir ano ibig sabihin ng LimBEPM STATUS

    • @MarkMinoza
      @MarkMinoza  3 года назад

      Limited By EPM = active ang limiter po.

    • @llewellynala6807
      @llewellynala6807 3 года назад

      @@MarkMinoza meaning pag active na siya pagmag sobra ang supply ng pv solar hindi ko eto consumption? Tama ba?

    • @MarkMinoza
      @MarkMinoza  3 года назад

      @@llewellynala6807 hindi ka po mag export ng power sa grid. Pag sobra ang pv generation, e limit ng inverter, e supply lang nya anong current load mo sa bahay.

    • @llewellynala6807
      @llewellynala6807 3 года назад

      @@MarkMinoza curious lang talaga ako sir . Kasi meron ako clamp meter pagtumaas ang harvest napansin ko sa clamp meter ko tumaas din ang consumptions ko. Hindi kaya instead na makatipid eh mas lalong madadagdagan consumptiins ko sir? Or baka merong settings na kailangan ko pang e configure. Need your thoughts po sir. Tnx

    • @llewellynala6807
      @llewellynala6807 3 года назад

      Tsaka para wala kasing indicator dito sa screen kung nag produce at nag export ba etong grid inverter ko

  • @arielyu7103
    @arielyu7103 10 месяцев назад

    Hello sir, paano po setup ng ng limiter pag dalawang Solis grid tie na nka parallel? Hindi ko kasi mkita sa manual. Salamat po

    • @MarkMinoza
      @MarkMinoza  10 месяцев назад

      Connect both CT on live wire, or use external EPM to consolidate your graphs.

    • @arielyu7103
      @arielyu7103 10 месяцев назад

      @MarkMinoza salamat sir.. kahit 6-10pcs na ct sensor pwede ilagay lahat sa live wire?

    • @MarkMinoza
      @MarkMinoza  10 месяцев назад

      @@arielyu7103 parallel still stable at 2 GTi, more than that, you need EPM if you plan to limit it. But if you don't. EPM is optional. For more info on EPM, kindly see this video.
      ruclips.net/user/liveyOFpafL-h4o?si=F-OjJ9nODGJygkuA

    • @arielyu7103
      @arielyu7103 10 месяцев назад

      ​@@MarkMinozacopy. salamat sa pag share ng knowledge sir.