I can't like this vid twice. I liked this vid maybe a year ago and I'm back again just get the definition and difference of the three. Thanks for sharing.
These are great videos thanks from the UK, I'm building a solar system, I understand DC due to working with DC for a hobby, but AC is still a bit of a mystery. Thanks for taking the time to make the videos
Yes. It is good to point out and (ruclips.net/channel/UCdKPm5KM99O75NtArFkMDDA) @The Electrical Guy is kindly requested to include it in your next video.
Really thank you for this enlighting video my friend. I begun searching the differences just for curiosity and you explained everything very,very well!
Thank you so much for sharing your knowledge and wisdom and making it understandable for a beginner like me. My boss and coworkers will not slowdown to teach or explain anything to me, thank you again.
I live in high rise building. Many electronic and electrical devices like computers, washing machine are flowing electrical current which gives a shock. They say it is earthing problem and solutions are for ground level homes and not for high rise. How do we overcome such problem in high rise building?
So... I got a couple of these to use on my solar system. One of them is backwards on instead of being off when green its red when its off. And then when I switch it to green its flowing power. The others are all different than that where red means power is on or 'hot'. What do you do to fix it when they are backwards on the on and off switch? And has this happened to others with them having the off and on switch function being backwards?
bro RCCB is connected to MCB just after the meter MCB, now anywhere in the house if any short-circuit happens in any device this RCCB will trip so entire house is protected from leakage ? or it only protects the meter ?
Nice one, but which are the best protection of short circut, shock, overload and also to get proper electric supply of a big house, do we need all of them or which one based on the above issues?
Very well explained, thank you. A question, you mentioned that RCCB with 40A means, a maximum of 40A can flow through it. But what if more than 40A flows? Won't it trip?
40A on RCCB told us that we can use the RCCB with Maximum 40A if you flow current more than 40A it terminal will Start heating and it will burn You will not get overload protection by RCCB
Glad you are making videos in English. It's very helpful for non Hindi speaking people also
Really educational and clearly explained
Now it is in English I can understand .More of this please. Thank you so much.
Now you make me understand the difference amongst these breakers. Thank you very much.
Watching from Australia. Really clearly explained. Thanks
I can't like this vid twice. I liked this vid maybe a year ago and I'm back again just get the definition and difference of the three. Thanks for sharing.
For the first time I comprehended easily..great lectures. Thank you
That was impressive sir thank you !!
Thank you
You made me to understand the difference between the breakers.
These are great videos thanks from the UK, I'm building a solar system, I understand DC due to working with DC for a hobby, but AC is still a bit of a mystery. Thanks for taking the time to make the videos
One thing you forgot to mention was the Overload Trip classes A, B, C, D
Yes. It is good to point out and (ruclips.net/channel/UCdKPm5KM99O75NtArFkMDDA)
@The Electrical Guy is kindly requested to include it in your next video.
Really thank you for this enlighting video my friend. I begun searching the differences just for curiosity and you explained everything very,very well!
Thank you so much for sharing your knowledge and wisdom and making it understandable for a beginner like me. My boss and coworkers will not slowdown to teach or explain anything to me, thank you again.
Good video on RCCB RCBO. Thank you.
Amazing explanation...I have learn new things from dis video
Very useful explanation among other RUclips Channels. Thank you very much keep doing it!!
Good and clear explanation👍👍
Keep it up
A good teacher indeed
Thank you for sharing with such simplicity and also for sharing in English
Beautifully explained
Thank you for the detailed explanation.
Sir, Really very good explanation. Hearty thaks
Nice one
Infact you do all,God bless you
very clear explanation and very useful. thanks
Thanks for sharing this vital information.
Simple yet informative
Thank you sir ,very very helpfull information
Very helpful keep it up
Very well explained! Thank you.
Thank you for this very informative video about circuit breaker.
Great explanation! One question! Which one can save us from Neutral failure/cut-off?!!
Thanks so much, very clear explanation ❤
Good information
thank you i wondered if RCBO had earth fault protection now i know it does
Very informative
Great details, nicely explained.
Thanks for the teaching !
Thanks for sharing it with us
thank you, things a lot clearer now
Nice information thank you
Thanks from France Samuel.. !
*Thank you. I use RCBO. RCBO is the best*
This was helpful... thank you
Thank you sir! that is a very useful information.
Very nice described
I want to buy a RCBO CNC but I am confused to choose between RCBO CNC YCB9LE-80M or YCB9L-40 ??? What do you recommend
Good, clear explanation
Well done sir.
Good video
Very Nice !!! I love to learn here.
Thank you I learn something new
thank you very much, sir!👍👍👍😊😊😊
Thankyou very much,
Nice video... 👍👍👍
You made it clear
Good job bro,big up from 🇹🇿🇹🇿
Well explained. Thank you
I live in high rise building. Many electronic and electrical devices like computers, washing machine are flowing electrical current which gives a shock. They say it is earthing problem and solutions are for ground level homes and not for high rise. How do we overcome such problem in high rise building?
Sir, can we put 3 pole rcbo before rooms mbc distribution or between main/ meter line and mcbs of rooms .
Thanks
Very nice
Hello all points are cover . I am wasting my time searching in RUclips . thanks again
Can I use it for 110v connection?
So... I got a couple of these to use on my solar system. One of them is backwards on instead of being off when green its red when its off. And then when I switch it to green its flowing power. The others are all different than that where red means power is on or 'hot'.
What do you do to fix it when they are backwards on the on and off switch?
And has this happened to others with them having the off and on switch function being backwards?
Good.
😊 thank you sir
Thanks u bro... Nice 👏
Nice. Thanks.
Good sharing upload video 👍👍
Thanks 👍
bro RCCB is connected to MCB just after the meter MCB, now anywhere in the house if any short-circuit happens in any device this RCCB will trip so entire house is protected from leakage ? or it only protects the meter ?
👍
Types of RCCB ki video please?
GREAAAAAAAT
good
I'd like to know what will happen if there is 50A current and 0 leakage current flow into a 40A/10mA RCCB, it's not safe but will the RCCB trip?
Is CNC breakers are good to use
Sir 2 kw load le liye kitne Ampere ka RCBO lagayein?
Both of them, can I use at once?
Yes
Thanks!
noce vids,
Thanks
Nice one, but which are the best protection of short circut, shock, overload and also to get proper electric supply of a big house, do we need all of them or which one based on the above issues?
Very well explained, thank you. A question, you mentioned that RCCB with 40A means, a maximum of 40A can flow through it. But what if more than 40A flows? Won't it trip?
rccb does not protect from current overload..
to simply answer your question, it would go in smokes or burn.
No , only a chance to get damaged..
40A on RCCB told us that we can use the RCCB with Maximum 40A
if you flow current more than 40A it terminal will Start heating and it will burn
You will not get overload protection by RCCB
@@TheElectricalGuy Understood. Thank you.
Sir sa RCBO PO BA PEDE.GAMITIN SA AIRCON
you really described it well . Thank you so much and u earned a new subscriber
❤
1:50 C32 will trip when current is 160A to 320A.
Thx
Neutral should be zero current, only live should have current
will an RCCB protect from electric shock if my home don't have ground ??
So if it mean i could use the RCBO with RCCB both sided aren't finest way ?
Pls make video of full house wiring
video is available on channel you can watch
What is the Im value of RCBO circuit breaker?
Sir a b c tripping current and time of RCBO is what.
Lekin rcbo purchase kaha se karne ki.
Yaha ahmedabad me dukan pe nahi hai.
Product link
amzn.to/46BktkR
Magnificient
Which capacity RCBO used for Double bedroom room.. i.e Amps & milli Amps
For lighting circuit use 10 Amp and 30 mA RCBO
For power 16 A 30mA
♥️♥️♥️♥️