  • @Coreengineers
    @Coreengineers  Год назад +2

    Watch more technical videos:🛠️👇
    1. Industrial Engineering Videos:
    ruclips.net/p/PLrqNx2OqGF51_BYmmF_z2TrR2x0EkVH3z
    2.Industrial Pump Videos: ruclips.net/p/PLrqNx2OqGF51IVvA2ivV1XdiMRnlWMLsC
    3. Centrifugal Pump Videos:
    ruclips.net/p/PLrqNx2OqGF513HW1AN7M9sw0kTqnO1ESX
    4. Instrumentation Engineering Videos:
    ruclips.net/p/PLrqNx2OqGF50F-gYBOccjSb9E-9F8zCi7
    5. Piping Engineering Videos:
    ruclips.net/p/PLrqNx2OqGF513CRbtuqu77IKBuIak9M3S

  • @mkbhuin6193
    @mkbhuin6193 Год назад +3

    I think the valve will remain open till defferential pressure is maintained 20 bar. Whenever there is a change in pressure either upstream or downstream the valve will close thus it maintains 20 bar pressure in the line. Is my understanding correct.

  • @manishankarraju5354
    @manishankarraju5354 Год назад +1

    Please make one video on different types of pump characteristic curves

  • @chemicalengineer1985
    @chemicalengineer1985 Год назад +1

    What is criteria of accentric and concentric flange to control valve.

    • @Coreengineers
      @Coreengineers  Год назад +1

      I have covered that topic in the reducer and expander video

  • @saikrishnasai2686
    @saikrishnasai2686 Год назад +1

    Sir please make a video on utility system ( offsites)

  • @GajendranGajendran-g8n
    @GajendranGajendran-g8n 9 месяцев назад +1

    Sir could you please draw the one p&id source to the destination to transfer the water as an interview poin mode. Including Nrv, reducer, strain, valve

  • @mohd.faisalbagban8242
    @mohd.faisalbagban8242 Год назад +1

    The valve may fail or get damaged due to the excessive pressure. This could result in leakage, which can be unsafe and lead to system failures.

  • @pranali6meshram707
    @pranali6meshram707 Год назад +1

    How to calculate shut off pressure of control valve

    • @Coreengineers
      @Coreengineers  Год назад +1

      We will make the video soon about it

    • @pranali6meshram707
      @pranali6meshram707 8 месяцев назад

      Design pressure -downstream pressure am I correct

  • @altafshaikh-vt6hq
    @altafshaikh-vt6hq 7 месяцев назад +2

    Control valve will not close becos the shut off pressure 40 bar is higher than 20 bar design oressure of the valve

  • @infodailyhub2352
    @infodailyhub2352 9 месяцев назад

    please make videos in hindi🙏