  • This video shows that what is cranked bar, why we provide cranked bar in beam with 3D animation of cranked bar. For more details please watch full video.
    Our channel brings civil engineering videos for students of Diploma, B-tech, M-tech, Bachelors and Masters.
    Subscribe our channel for more civil engineering videos.
    / civilengineeringonlyci...
    #Cranked #Bar #Beam

Комментарии • 187

  • @civilengineering94
    @civilengineering94  Год назад

    Subscribe to my new Channel :)
    ruclips.net/channel/UCFON1In_xIuPqWc_GGWawUQ

  • @Panther-
    @Panther- 4 месяца назад +1

    The clearest explanation of why you need cranck bars at the point of where the beam meets the column is the best explanation I have seen thus far even doing a structural engineering diploma course which is pretty good, but they never explained it where I got it instantly like this.

  • @arthurtorin7098
    @arthurtorin7098 14 дней назад +1

    Clearly you fully understand the topic as the visual drawings are great. Although, I struggled to understand a few names at key points. I appreciate that teaching in a second language is no easy thing. Would love to have understood more (Y)

  • @MKo-cu5rn
    @MKo-cu5rn Год назад +1

    Again for the million time i came to a conclusion that youtube is better than all my professors !

  • @sasalshinas9166
    @sasalshinas9166 4 года назад +6

    I never get this much information from my college. Thank you so much Sir. Thanks a lot. You are a very good teacher .

    • @civilengineering94
      @civilengineering94  4 года назад

      Thanks #Sasal

    • @guardrailbiter
      @guardrailbiter 4 года назад

      But, how am I supposed to 'earn' an honorary engineering degree if you don't upload the entire textbook?

  • @dipakhadonge7317
    @dipakhadonge7317 4 года назад +1

    Thanks sir
    Clearly understood concept in beam section

  • @gopalvaer5651
    @gopalvaer5651 4 года назад +3

    What are effect if used two tops over two pillars instead of CRANKS!
    DOES IT SAME EFFECT OR NOT?
    PLEASE RESPONSE

    • @69bibin
      @69bibin 4 года назад +5

      basically, it is the same. this method is prospected to be more economical than without cranks. however, some standard doesn't allow cranking more than 1:6. Also the bending skill on producing cranks like this is a bit hard (especially > 25 mm bars).

  • @untouchable9917
    @untouchable9917 4 года назад +14

    The best explanation l have got on positive and negative bending moment of beam l clearly understood it now thanks

  • @angelremigiocardenasgutier2422
    @angelremigiocardenasgutier2422 3 года назад +1

    Explicación super detallada MAESTRO. Felicitaciones

  • @cnetInc
    @cnetInc 4 года назад +1

    very clear explanation.Thank you very much sir.best of luck for you...amal from - sri lanka

  • @ManneLearningAcademy
    @ManneLearningAcademy 3 года назад +1

    Interesting! I am an avid fan of yours. I was learning everytime you uploaded new content. Thank you.

  • @khadarvalipathan5821
    @khadarvalipathan5821 4 года назад

    superb explanation...thank u sir

  • @anashashmi979
    @anashashmi979 4 года назад +1

    Ur explanation can easily understand thnks sir

  • @shalzmv1
    @shalzmv1 Год назад +1

    Sorry to as a question that might be silly....I don't have any background in civil engineering but I am getting a house constructed. So I have been watching some of your videos. As the position of the crank bar is where overlaps are not allowed, does it mean that no overlaps are allowed in a crank bar?

  • @tsclly2377
    @tsclly2377 4 года назад

    so what about using 3-4" galvanized nails mixed in the cement batch for the cost savings in time one could add 100% more steel in mass ..

  • @kennedy1727
    @kennedy1727 4 года назад +1

    Sir nice video but I have doubt how can 8.8 inch bar can reach bottom of 1.5 inch in slanting conditions please explain me

  • @wingscanemandrae8883
    @wingscanemandrae8883 3 года назад

    Thank you very much it helps a lot...there's a lot of confusions in rebars but you explained it so clear Godbless you

  • @mohanbabupm5778
    @mohanbabupm5778 2 года назад

    What as amazing teaching skills god has bestowed on u sir l have grasped the concept immaculately thank u gentleman

  • @khondokerazizulhaque357
    @khondokerazizulhaque357 Год назад +1

    Most of us learn the things from you tuber like u sir ..what's the role of colleges?

  • @DGDG0000000
    @DGDG0000000 4 года назад

    Vert good, i didn't know that. i know pre constraint tensioning rebar beam.

  • @kennedy1727
    @kennedy1727 4 года назад

    Nice explanation video sir thank you for this video sir

  • @engineermoon
    @engineermoon 5 лет назад

    Thnks alot sir

  • @sheikhkais4140
    @sheikhkais4140 5 лет назад

    Thank u sir

  • @MasterCivilEngineering
    @MasterCivilEngineering 3 года назад +1

    Expertise in civil engineering here

  • @sheikhkais4140
    @sheikhkais4140 5 лет назад

    Fantastic

  • @iacsse6381
    @iacsse6381 4 года назад

    What about columns bending movement? Can crank transfer directly from a column to another? Today lifted bars...

    • @MitzvosGolem1
      @MitzvosGolem1 4 года назад

      Yes determined by advanced moment frame analysis as Finite element analysis method etc.

  • @doctormcgoveran2194
    @doctormcgoveran2194 4 года назад

    I am curious why not three bars with the top two over lapping the bottom?

  • @Arun930
    @Arun930 4 года назад

    Excellent Effort! Keep Rocking

  • @tajamulhussain3682
    @tajamulhussain3682 4 года назад

    Sir would you please upload a video on how we decide the position on slabs as well as on beams to crank the bars.i mean thumb rules to find the location on beams and slabs where bars will be cranked

  • @Habesha5473
    @Habesha5473 3 года назад

    very important vedio, even it decrease wastage of Re-bares, for lapping and splice . 10Q a lot

  • @sasalshinas9166
    @sasalshinas9166 4 года назад +1

    Sir , please do some videos about how to calculate the total length of a bend up bars with hook and tell some interview questions too....

  • @sitaljoy307
    @sitaljoy307 4 года назад +9

    It's √2D i.e. 1.42D not 0.42D because cranked bars are bent at 45 degree.. It's simple trigonometry

    • @letslearntv2692
      @letslearntv2692 4 года назад +2

      Sital Joy he is correct man. It’s is 0.42D only not 1.42.D.. D indicates depth of the beam

    • @ronmix1063
      @ronmix1063 4 года назад

      @@letslearntv2692 you're wrong mn. Common sense how can you connect the the top ang bottom bars if you only use .42 of the depth? It should be more than 100% the length of the depth

  • @johnathanlivingstonseagull5524
    @johnathanlivingstonseagull5524 4 года назад

    Distance is offset of the crank but what is that point from midspan? 1/3rd?

  • @ermengolrafael6281
    @ermengolrafael6281 2 года назад +1

    Excelent explanation, I was asking for it. Thank you.

  • @anashashmi979
    @anashashmi979 4 года назад +1

    Thanks bro

  • @fathimarumeena4135
    @fathimarumeena4135 3 года назад

    Sir, how to place his crank bar for a rcc beam which is upstanding (above slab) 13" (with slab 5" = 18").
    Beam Length is 20'

  • @tekdhant3731
    @tekdhant3731 4 года назад

    What’s the name of music played in the start of video??

  • @101raziel905
    @101raziel905 3 месяца назад +1

    Can you upload how to calculate a concrete slab on piles straight with no culmbs like a bridg in water or a ro ro platform please 🙏

  • @mohamedag8366
    @mohamedag8366 3 года назад +1

    How did you calculate L = 0.42 *D ? which code did you follow?

  • @supreethdraj3749
    @supreethdraj3749 3 года назад

    Super Sir really want this analysis sir♥️

  • @sakilsamrat1542
    @sakilsamrat1542 5 лет назад

    Excellent

  • @ferozahmed3353
    @ferozahmed3353 4 года назад

    Good explanation!

  • @kumaranshankar9463
    @kumaranshankar9463 4 года назад

    Wow thanku you I understand well

  • @manhessami
    @manhessami 4 года назад

    I am agree with gopal and think the same.

  • @shornyify
    @shornyify 4 года назад +4

    How can length of crank be less than D ??...also do the cranked bars help to resist vertical shear force ?

    • @MitzvosGolem1
      @MitzvosGolem1 4 года назад

      Shear at ends is 45° to longitudinal axis and is 1.5 times the stress found in pure vertical shear stress at maximum end reaction only on a simply supported beam..

  • @anieschaudhary7684
    @anieschaudhary7684 4 года назад +3

    My question is "if its placed in whatever angle i.e 45° in this case, then the length of the cranked will automatically be determined...right??

  • @yodaiam1000
    @yodaiam1000 4 года назад +2

    I think you meant 1.41 and not 0.42? The hypotenuse of a right triangle can't be less in length than one of the sides of a triangle.
    You also did not explain why you need to crank the bar. Why not just have steel at the ends on the top and on the bottom for the middle. Why add the additional cost of cracking the bar?

  • @karanamjbrao7889
    @karanamjbrao7889 3 года назад +1

    Pl.ae
    Share all your videos

  • @inhinyerongsibil6383
    @inhinyerongsibil6383 4 года назад

    Nice content this is usefull for us

  • @spatapoint8821
    @spatapoint8821 3 года назад

    Thank you so much.. very nice lecture sir

  • @MegaCrap90
    @MegaCrap90 3 года назад

    how to know at what distance the crank should be made?

  • @awqpak
    @awqpak 4 года назад +1

    Are cranked bars required if the beam is laid on earth soil?

  • @3dworld883
    @3dworld883 4 года назад

    well done virora..deer kha.. if you are pakhtoon then I hope you will must be like it :-)

  • @Lalekrushna
    @Lalekrushna 3 года назад

    Great sir

  • @sudeeprai9536
    @sudeeprai9536 4 года назад +4

    Please review the length of cranked bar..
    Its not actually the length of inclined bar..
    0.42D is the combine length along the base of complete base..
    Review using basic Pythagoras theorem..
    U have 45degree and perpendicular D.
    Soo inclination length comes to be D÷sin45
    ...
    0.42 comes after substitution of base length..
    Because when you calculate bar length you already include base length taking length of span

    • @sanjaykumar-dk8uw
      @sanjaykumar-dk8uw 4 года назад

      Bro there is no problem with length of span...use D only and find length of crank bar and I think D is depth of beam

    • @ronmix1063
      @ronmix1063 4 года назад +1

      @@sanjaykumar-dk8uw its wrong man. Think about this. If it is .42 of the Depth so .42×24=10.8, the distance of top and bottom bars is 21. So how will you connect that with only having 10.8 inches of length

  • @sukantaroy1202
    @sukantaroy1202 4 года назад +1

    If it's 45degree angle , then the length of Crank must be equal to Diagonal length , can be derived by Pithagorus theorem (Right angle triangle), i.e 1.42*d or 1.42*21".
    I Dnt think ur formula is right as per geometry atleast.

  • @basavarajkv7091
    @basavarajkv7091 4 года назад

    Excellent ,

  • @balashivam6720
    @balashivam6720 3 года назад

    1)When do we provide cranked bars???
    2)do we need to cranked the steel bars which we r going to provide or we need to put an extra bar ???
    3)do every beams have cranked bar ?
    4)In design steps of beam , is there any step for cranked bar ????

  • @mehrzadrashidkhani3250
    @mehrzadrashidkhani3250 3 года назад

    Thank you Sir.
    🙏🙏🙏

  • @russmancherose6946
    @russmancherose6946 4 года назад +1

    Good

  • @madiha1750
    @madiha1750 4 года назад

    Is there any anchor bars in the upper side

    • @civilengineering94
      @civilengineering94  4 года назад

      2 compression bars must be there, other bars depends on your design

  • @123rockstar2010
    @123rockstar2010 3 года назад +5

    The diagonal distance (hypD) is 1.42D not 0.42D.
    D = Beam Depth - 2 x Cover - Tie Diameter [10mm or 0.394]
    D = 24in - 2x1.5in - 0.394in
    D = 20.606in
    NOTE: 45°, horizontal length = vertical length = D
    hypD² = D² + D²
    hypD = sqrt( D²+ D²)
    hypD = 29.141in
    k x D = hypD
    k = hypD / D
    k = 29.141 / 20.606
    k = 1.42

  • @johnhaokip4008
    @johnhaokip4008 4 года назад

    Is it possible to remove the diagonal beam i. e which is put at 45°

    • @johnhaokip4008
      @johnhaokip4008 4 года назад

      Or is it a different type of crank bar design. Can you differentiate their function.

  • @prajwalmasurkar9487
    @prajwalmasurkar9487 3 года назад +1

    Where provide crank bar in plint beam

  • @ranjankumarsahoo6326
    @ranjankumarsahoo6326 4 года назад

    Great

  • @RaviShankar-uk2bd
    @RaviShankar-uk2bd 5 лет назад +1

    What should be the angle made for crank bars?

  • @techirupchi5073
    @techirupchi5073 2 года назад

    Whether we should provide single crank or double crank bar in a beam??

  • @rayaytatatuntatnafurtat2029
    @rayaytatatuntatnafurtat2029 3 года назад

    Thank you.

  • @prafulkindo5445
    @prafulkindo5445 3 года назад

    Well done.!

  • @abdurrahim3605
    @abdurrahim3605 2 года назад

    Thanks

  • @ganeshganee9572
    @ganeshganee9572 3 года назад +3

    Great presentation of concept. Best explanation that i ever seen about actual concepts of reinforcement provision at beam and reason for that.

  • @dr.v.selvanvelusamy1335
    @dr.v.selvanvelusamy1335 4 года назад +3

    Thanks for the excellent webinar.Dr.V.Selvan,KCT,Coimbatore-49

  • @loiccooper1425
    @loiccooper1425 Год назад

    Thanks for this video

  • @jagadishk639
    @jagadishk639 4 года назад +2

    How inclined length of crank bar is less than half( 0.42) of straight depth. I think there is some correction.

    • @sitaljoy307
      @sitaljoy307 4 года назад +1

      It's √2D or 1.42D not 0.42D.
      Simple trigonometry calculation

    • @jagadishk639
      @jagadishk639 4 года назад

      @@sitaljoy307 √2d only for 45° right angle triangle.

    • @jagadishk639
      @jagadishk639 4 года назад

      @@sitaljoy307 video thumbnail itself showing length is 0.42D.

    • @sitaljoy307
      @sitaljoy307 4 года назад

      @@jagadishk639 for whatever angle provided cranked bar length is always greater than D.. Any value less than D is impractical

    • @jagadishk639
      @jagadishk639 4 года назад

      @@sitaljoy307 I am asking for that correction 😁

  • @elizabeth3521
    @elizabeth3521 2 года назад

    Masterclass

  • @nizamali7027
    @nizamali7027 3 месяца назад +1

    Nice

  • @AlejandroCruz67
    @AlejandroCruz67 3 года назад

    If i had learned this before at the University...

  • @phyohtetkoko929
    @phyohtetkoko929 2 года назад

    Thanks For Teaching Sir

  • @gopalvaer5651
    @gopalvaer5651 4 года назад +8

    Crank bends,
    8.8 " does not fit within your (24' -3") = 21" height beam.

    • @shobanbabuketavathu5783
      @shobanbabuketavathu5783 4 года назад

      Yes

    • @liasdigitalmedia7594
      @liasdigitalmedia7594 4 года назад

      Gopal Va'er 59

    • @anieschaudhary7684
      @anieschaudhary7684 4 года назад +2

      Yes....i have a similar confusion. If the angle is maintained at 45°, then the length of the cranked bar will automatically be determined..... but still 0.42 doesnot work...1.42 is correct

    • @ToiletTrained1928
      @ToiletTrained1928 3 года назад

      @@anieschaudhary7684 comon guyz create a square at 21 inch x 21 inch find the length between 2 points
      there u go

    • @gilmorebacud9396
      @gilmorebacud9396 3 года назад

      0.42 x D = Hypotenuse.
      How come that D is longer than the hypotenuse. I think you miss + D sir.

  • @ks-pi1ut
    @ks-pi1ut 2 года назад

    Good information sir

  • @jigarpatel1727
    @jigarpatel1727 5 лет назад

    👍👍

  • @surveyingengineeringdesigninfo
    @surveyingengineeringdesigninfo 3 года назад

    good

  • @elxanhafizli736
    @elxanhafizli736 4 года назад +1

    My question is : is crancked bar also for save money? I am askim because of why you did not use 6bars for beam. 6bars are safely they can work positive and negative loads easily. Could u please answer my question? Many thanks

    • @civilengineering94
      @civilengineering94  4 года назад +2

      yes cranked bar are economical as compare to other options

  • @zoteasailofs1526
    @zoteasailofs1526 2 года назад

    I like it

  • @kevinnewell2561
    @kevinnewell2561 3 года назад

    Where u put lapping in the slabs

  • @vreddyb4552
    @vreddyb4552 3 года назад

    Super, Wonderful

  • @jaimehernandezperez5267
    @jaimehernandezperez5267 3 года назад

    Perdón es 21/0.7071=29.7, o sea 21/sen45°=29.7. Tambien puede ser 1.414x21=29.7.

  • @jaimehernandezperez5267
    @jaimehernandezperez5267 3 года назад

    La respuesta correcta es 21"x0.7071=29.7". Creo que esto fué a ver si ponen atención.

  • @touhiduzzamanraihan6619
    @touhiduzzamanraihan6619 4 года назад

    ❤❤❤❤❤❤

  • @mannexyee737
    @mannexyee737 3 года назад

    Youre placing your crank bar at the opposite. A crank bar is just the same design as a lift spring of a vehicle or the arc of an old bridge.

  • @hectorolimpogarciasandoval5123
    @hectorolimpogarciasandoval5123 4 года назад

    Excelente explicación...solo que las letras negras no dejan ver la explicacion en el pizarron.

  • @devilzpwb7596
    @devilzpwb7596 3 года назад +1

    Sound is very low n not clear...

  • @chennojumahender2087
    @chennojumahender2087 2 года назад

    0.42D may not be correct
    Diagonal length will be more than D

  • @meersarwar3604
    @meersarwar3604 4 года назад +2

    Use either 45 degree or 0.42d.not logical to use both lol

  • @christiesebaratnam9155
    @christiesebaratnam9155 4 года назад +4

    This is an outdated design . According to the design codes in the past more than 30 years , there is the requirement for certain amount of positive moment reinforcement to be anchored past the face of support . The anchorage past the face the support should be able to develop a force of 1.5x shear force at the support

  • @ako524mobilegaming7
    @ako524mobilegaming7 4 года назад

    I guess the cranked bar is phasing out.

  • @pedroveralopez9674
    @pedroveralopez9674 4 года назад

    tambien escrbelo y explicalo en español amigo xq yo veo tus videos desde veracruz mexico

  • @jagdeezlal3982
    @jagdeezlal3982 2 года назад

    The length of the crank bar should be 1.42 D not 0.42 D

  • @saddamislam9900
    @saddamislam9900 Год назад

    Sir ji crank length must be 1.42D not 0.42D.

  • @dannyfreeman1427
    @dannyfreeman1427 4 года назад

    WHAT ABOUT DOME ROOF