How to Install and Setup POW SunSmart10K Solar Inverter

Поделиться
HTML-код
  • Опубликовано: 18 июл 2023
  • Are you ready to take control of your energy supply and embrace renewable power solutions? Join us on our exciting journey to unlock the full potential of solar energy with the POW SunSmart10K solar inverter installation and setup guide!
    In this highly informative video, we will walk you through the step-by-step process of installing and configuring the POW SunSmart10K solar inverter. Our expert technicians will share valuable insights, tips, and best practices to ensure a smooth and successful installation.
    ______________________________________________________________
    Website
    powmr.com/
    Facebook
    / powmrsolar
    Email:
    support@powmr.com
    See you in my next video! :)
    ______________________________________________________________
    1: PowMr New 5KW Energy Storage System Unboxing
    • PowMr New 5KW Energy S...
    2: PowMr 10KW Solar Inverter Unboxing
    • PowMr 10KW Solar Inver...
    3: Detailed Solar Inverter Installation: A Step-by-Step Guide
    • Detailed Solar Inverte...
    4: Detailed Explanation of POW SunSmart5.5KW Time-of-Use Charging and Discharging
    • Detailed Explanation o...
    5: Inverter Setup Guide: A Comprehensive Tutorial for Beginners
    • Inverter Setup Guide: ...
  • НаукаНаука

Комментарии • 92

  • @TwoK24
    @TwoK24 8 месяцев назад +1

    Nice tutorial POWMR

  • @dannysuru
    @dannysuru 10 месяцев назад +1

    Hi looks good but can I use a generator to ac input when no sunshine and off grid ?

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад +1

      Yes. you can use a generator to connect this model.

  • @freddyc2121
    @freddyc2121 6 месяцев назад +1

    Hello, I need information about the wiring, I already saw the video,I already read the manuel, but in case I need to bypass from input from utility AC 240V, how do I apply the 240V comming from the mains to the inverter and the load , in the video it shows from input 120v , but if I need to use L1 and L2 + N at the input to feed the load and to charge the battery.
    Let's say, I use a laundry dryer at 240V connected to the inverter that will runn fom the batteries only of the utility power goes off, so initially it will take from utility at 240V and then if power from the grid fails, it will switch to batteries.

  • @JeffSmith-hq2gw
    @JeffSmith-hq2gw Месяц назад

    Impressive

  • @sgn8471
    @sgn8471 7 месяцев назад

    Hi Powmr, which model and watts can be Parallels..? and what’s AC Main output and 2nd AC output…? Thanks….I’m going setup a 48v to 240v system

    • @PowmrSolar
      @PowmrSolar  7 месяцев назад

      Hi, this model can be used in parallel. The product link for your checking as below: powmr.com/products/hybrid-inverter-charger-5000w-48vdc-110vac-for-parallel

  • @esdrasemile1450
    @esdrasemile1450 5 месяцев назад

    Good morning

  • @JesusPaidForYourSins7
    @JesusPaidForYourSins7 4 месяца назад

    Hello. I bought this inverter and have it connected to a 48v lifepo4 200ah battery. I have problems charging and discharging the battery. When it discharges, the inverter trips the OC protection. Are there specific parameters I should set for the battery? Would be great if the inverter and the battery could regulate these parameters.

    • @PowmrSolar
      @PowmrSolar  4 месяца назад

      Hi, please send your problem to this email: support@powmr.com. Please note that we may not be able to promptly respond to you due to the Lunar New Year. We apologize for the inconvenience this may take and thank you for your understanding. We wish you all the best!

  • @ramsaybolton9099
    @ramsaybolton9099 11 месяцев назад

    Thank you for this video, it was quite comprehensive. Can this unit can be monitored by an app?

    • @PowmrSolar
      @PowmrSolar  11 месяцев назад

      Hi, this APP(SmartESS).

  • @harty9018
    @harty9018 11 месяцев назад +2

    ist der SunSmart10K in parallel Schaltung möglich ( 2x SunSmart10K auf 2 Phasen ?

    • @PowmrSolar
      @PowmrSolar  11 месяцев назад +1

      Hi, this model cannot be used in parallel.

  • @johnmelvin808
    @johnmelvin808 4 месяца назад +1

    I've been utilizing my 10k solar inverter for nearly half a year, and overall, it has proven to be a highly satisfactory experience. However, I have observed that when encountering an error code, is there a more efficient method to reset the code without the need to power down the entire system and initiate a complete reboot? Thanks for a great product.

    • @PowmrSolar
      @PowmrSolar  4 месяца назад

      Hi, please send your problems to this email: support@powmr.com. Please note that we may not be able to promptly respond to you due to the Lunar New Year. We apologize for the inconvenience this may take and thank you for your understanding. We wish you all the best!

  • @MrBmonroe924
    @MrBmonroe924 11 месяцев назад +1

    are you able to wire two of these units in parallel?

    • @PowmrSolar
      @PowmrSolar  11 месяцев назад

      This model cannot be used in parallel

  • @MiguelLlanes-vn1wc
    @MiguelLlanes-vn1wc 8 месяцев назад

    Puedo conectar paneles orientados al este a una entrada de paneles y orientados al oeste a la otra

    • @PowmrSolar
      @PowmrSolar  8 месяцев назад

      Yes, you can connect like this.

  • @davemacdonald5106
    @davemacdonald5106 9 месяцев назад +1

    is this CSA and UL certified

  • @mattclark7941
    @mattclark7941 Месяц назад

    Hi will this inverter put out 230v to 240v in the single phase for uk?

    • @PowmrSolar
      @PowmrSolar  Месяц назад

      Hi, this model is only for USA.

  • @johnmelvin4091
    @johnmelvin4091 10 месяцев назад +1

    If i have a 4 -12 volt lifepo4 batteries setup for 48 volts, which setting should I use. LFP14, LFP15, and LFP16?

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад +3

      Hi, LFP16.

    • @johnmelvin4091
      @johnmelvin4091 10 месяцев назад +4

      So, I read the manual from top to bottom and in it states that the LFP14, LFP15, and LLFP16 setting, is the number of cells in your battery setup. A 12 volt Lifepo4 battery has 4 cells x 4 batteries is 16 = LFP16. Just an FYI for anyone else wondering. Thank you for the quick reply.

  • @gabaradama144k9
    @gabaradama144k9 6 месяцев назад

    Do I have to have two units for 240 V split phase power

  • @atlw12210
    @atlw12210 8 месяцев назад

    POW-HVM5.5K-48V-LIP missing RS485 communication cable. How do I get one?

  • @healtechpr5659
    @healtechpr5659 10 месяцев назад +1

    Max. Voltage of Open Circuit 500Vdc, is it for each individual mppt, or is it 500vdc for both?

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад +1

      For each, but the maximum input current is that the sum of the two does not exceed the PV maximum input current(22A)

    • @healtechpr5659
      @healtechpr5659 10 месяцев назад +3

      @@PowmrSolar Ok, to see if I'm okay…
      1st Mppt 500Vdc
      2nd Mppt 500Vdc
      22A for both

    • @alisaggaf7497
      @alisaggaf7497 2 месяца назад +1

      Solar Panel array, Watts not to exceed 11KW

  • @jojohnny4386
    @jojohnny4386 5 месяцев назад

    Hello my inverter HVM4.5K-24V
    At the 12 marathon it doesn't have volts.
    How to set the Back to Battery?
    But why the ampers?
    How should it be set up?
    Or do I need to update the software?
    Thank you

    • @PowmrSolar
      @PowmrSolar  4 месяца назад

      Hi, please send your problems to this email: support@powmr.com. Please note that we may not be able to promptly respond to you due to the Lunar New Year. We apologize for the inconvenience this may take and thank you for your understanding. We wish you all the best!

  • @amelieelibh
    @amelieelibh 8 месяцев назад +1

    I installed the 10k power inverter with 8 550w solar panels in serial. Only in one MPPT, and I don't have batteries yet.
    It works sending V from the sonar panels and Utility to the load, but it is throwing an error 03. How can I configure it to work without requiring batteries?

    • @PowmrSolar
      @PowmrSolar  8 месяцев назад

      Hi, the POW SunSmart10K model, right?

    • @amelieelibh
      @amelieelibh 8 месяцев назад

      @@PowmrSolar correct!

    • @PowmrSolar
      @PowmrSolar  8 месяцев назад

      @@amelieelibh Please connect PV and mains power at the same time, then set AC 1ST in item 01 and LOD in item 34.

    • @amelieelibh
      @amelieelibh 8 месяцев назад

      @@PowmrSolar I already configured utility in the option 01, and mix load in the option 34. And it worked, but the battery alarm never finished and all the time throws fault (even working). Is there a way to configure it to avoid requesting for the batteries?

    • @PowmrSolar
      @PowmrSolar  8 месяцев назад +1

      @@amelieelibh You can turn off the alarm in item 25.

  • @MakeItAdmirable
    @MakeItAdmirable 11 месяцев назад +1

    Can you do a video for SP5K
    5000W 48Vdc 110Vac Hybrid Inverter Supports Up to 6 Units in Parallel

    • @PowmrSolar
      @PowmrSolar  11 месяцев назад +3

      Hi, Ok. Stay tuned we will arrange later.

    • @horaciojimenez3586
      @horaciojimenez3586 10 месяцев назад

      Si, seria muy interesante conocer esa configuracion y el equipo

  • @muhammadshahzadyousaf1282
    @muhammadshahzadyousaf1282 Месяц назад

    our inverter POW-HVM6.2M-48V-N installed a day ago, error 52 appears and the system is not restarting. what to do further? please advice.

    • @PowmrSolar
      @PowmrSolar  Месяц назад

      Please send your problem to this email: support@powmr.com. Our teachnical staff will handle it for you.

  • @homeinspectionlosangeles4189
    @homeinspectionlosangeles4189 11 месяцев назад +1

    can this 10k inverter work off grid without the utility connected(while solar pv and battery are connected)??

    • @PowmrSolar
      @PowmrSolar  11 месяцев назад +1

      HI, sure, this model can work off grid.

  • @vladflorin7821
    @vladflorin7821 4 месяца назад

    I have a question if not intruding, I recently bought a 10,2kw inverter and don't understand what they use two outputs for,Main output, Second output??
    I'm under the impression that is not a 10kw inverter, but two inverters of 5kw each!?!? Please explain to me to understand, in the user manual it doesn't say anything about this subject.. thanks, I appreciate..
    Looking forward for the answer

    • @PowmrSolar
      @PowmrSolar  3 месяца назад +1

      Hi, the distinction between primary and secondary. Under normal circumstances, the ordinary load is connected to the main load terminal. If the battery power is insufficient, the inverter will lose power and stop working. However, in order for some loads to be kept powered on all the time, there is a secondary load, which means that even if the battery power is a little low, the main load is still disconnected and only the secondary load is carried, thereby keeping the secondary load uninterrupted.
      This function requires setting items 41 and 42 to be turned on.

  • @Ozzie-bq8vq
    @Ozzie-bq8vq Месяц назад

    I just installed my 10K inverter and I can barely see the display, not bright enough, what am I doing wrong? Help!

    • @PowmrSolar
      @PowmrSolar  Месяц назад

      Hello, please send your problems to this email: support@powmr.com. Our technical staff will check it for you.

  • @mugiraharjo6270
    @mugiraharjo6270 3 месяца назад

    hope adding feature for paralel multiple inverter,

    • @PowmrSolar
      @PowmrSolar  3 месяца назад

      This model has a parallel version.

  • @christianbravophotography4705
    @christianbravophotography4705 10 месяцев назад

    How is the maximum capacity (kilowatts) in battery for this inverter?

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад

      Capacity is not required, but we suggest not to connect too much (200AH-400AH)

    • @alisaggaf7497
      @alisaggaf7497 2 месяца назад

      Can I connect 5 Units of Lifepo4 batteries 51.2x280AH (parallel) to this inverter?

  • @johsell07
    @johsell07 10 месяцев назад

    Do you have any e mail for support? I have a few questions of this sistem

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад +1

      kindly contact this email: support@powmr.com

  • @MakeItAdmirable
    @MakeItAdmirable 10 месяцев назад

    What is the difference between LFP14, LFP15, and LFP16? Im not sure which one to select.

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад

      Hi, we would like to know what is the voltage of your lithium battery.

    • @MakeItAdmirable
      @MakeItAdmirable 10 месяцев назад

      @@PowmrSolar
      51.2 volt 100Ah

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад +1

      @@MakeItAdmirable Recommend you choose LFP16.

    • @MakeItAdmirable
      @MakeItAdmirable 10 месяцев назад

      @@PowmrSolar
      Ok thank you!

  • @MiguelLlanes-vn1wc
    @MiguelLlanes-vn1wc 8 месяцев назад

    Hola

  • @TwoK24
    @TwoK24 10 месяцев назад

    What is the proper procedures for switching ON the inverter which first PV, BATTERY, AC IN?
    and what is for switching OFF which first PV,BATTERY ,AC?

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад +1

      Hi, you need to turn on the battery switch first, then PV, the last is AC IN.
      The order of turning them off is AC IN first, then PV, then battery.

    • @TwoK24
      @TwoK24 10 месяцев назад

      @@PowmrSolar thank you so much

  • @technadi4556
    @technadi4556 10 месяцев назад

    has this inverter a limiter

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад +1

      This model has built-in CT.

  • @johsell07
    @johsell07 10 месяцев назад

    How to contact you to buy the inverter?

    • @PowmrSolar
      @PowmrSolar  10 месяцев назад

      Hello, kindly check the website: powmr.com/

  • @JosephCaile-js1wq
    @JosephCaile-js1wq 4 месяца назад

    Where is the anti reflux settings?

  • @missinglink2081
    @missinglink2081 3 месяца назад

    why can't I change my parameter 01

    • @PowmrSolar
      @PowmrSolar  3 месяца назад

      Please send your questions to this email: support@powmr.com

  • @saulvasquez1058
    @saulvasquez1058 5 месяцев назад

    Please upload this video in Spanish. thank you

  • @ridersmotoz2457
    @ridersmotoz2457 9 месяцев назад

    Still available and Hm??

    • @PowmrSolar
      @PowmrSolar  9 месяцев назад

      Hi, this model(POW SunSmart10K)?

  • @bimmers323ci
    @bimmers323ci 4 месяца назад

    Hi is this unit stackable

    • @PowmrSolar
      @PowmrSolar  4 месяца назад

      Hi this model can't be used in parallel.

    • @bimmers323ci
      @bimmers323ci 4 месяца назад

      @@PowmrSolar hi can this inverter run two 4hp motor @ 240v

    • @PowmrSolar
      @PowmrSolar  4 месяца назад

      @@bimmers323ci Hi, this inverter can not run two 4hp motor at the same time.

    • @bimmers323ci
      @bimmers323ci 4 месяца назад

      @@PowmrSolar ok the what can you recommend

    • @PowmrSolar
      @PowmrSolar  4 месяца назад

      @@bimmers323ci Hi, you can use two units.

  • @directionschoolnoorcampus
    @directionschoolnoorcampus 8 месяцев назад

    Price in pkr

    • @PowmrSolar
      @PowmrSolar  8 месяцев назад

      Hi, kindly check the product link: powmr.com/products/hybrid-inverter-charger-10kw-48vdc-split-phase-110vac-or-240vac

  • @atlw12210
    @atlw12210 8 месяцев назад

    POW-HVM5.5K-48V-LIP missing RS485 communication cable. How do I get one?