Difference between VFD and Solar Inverter

Поделиться
HTML-код
  • Опубликовано: 9 ноя 2022
  • Difference between VFD and Solar Inverter
    VFD is a variable frequency drive and use in industry and solar tubewel for water pumping. And solar inverters are used in house and commercial places with batteries or without batteries . In this video i have explained the difference between these two
    For more Information Contact: 0311-4011444
  • НаукаНаука

Комментарии • 120

  • @zahoorulhaq986
    @zahoorulhaq986 Год назад +3

    Thank you janab ap ne itni zabardast video banai or ham ko sikhaya bhi

  • @waqifkhan4526
    @waqifkhan4526 Год назад +1

    زبردست جناب وقاص بھائی

  • @vaseem.k6839
    @vaseem.k6839 Год назад +1

    VERY NICE PRESENTATION SOLVED MANY QUESTIONS

  • @shahrukh5797
    @shahrukh5797 Месяц назад

    Very well explained JazakAllah

  • @farhanjani1142
    @farhanjani1142 2 месяца назад

    Thank you Bhai Jan informatave video

  • @relativerelations99888
    @relativerelations99888 15 дней назад

    بہت عمدہ شکریہ.

  • @muhammadafzal5472
    @muhammadafzal5472 3 месяца назад

    Very good information.

  • @zubairhaider4854
    @zubairhaider4854 3 месяца назад

    Great information.

  • @amr342
    @amr342 11 месяцев назад +1

    very good explaination

  • @HoneyAhmad-wi9xh
    @HoneyAhmad-wi9xh Месяц назад

    Very well explained 👍

  • @ExploreVerse
    @ExploreVerse Год назад +1

    Bohat khoub janab

  • @MuhammadHassanKhan-nf6wm
    @MuhammadHassanKhan-nf6wm Месяц назад

    Informative ❤

  • @user-yu4er7hy1x
    @user-yu4er7hy1x 4 месяца назад +1

    Well done.thanks

  • @HadiHadi-pk7eg
    @HadiHadi-pk7eg Год назад +2

    Good information

  • @mdessa2022
    @mdessa2022 Год назад +1

    Great speech 💬 bro 💞

  • @zeeshanshani6598
    @zeeshanshani6598 5 месяцев назад

    Good information 🎉🎉🎉

  • @8uhayat
    @8uhayat Год назад +1

    Very informative, thanks

  • @aamr9811
    @aamr9811 Год назад +2

    Best video 👍

  • @arqumshehzad489
    @arqumshehzad489 4 месяца назад

    5:26 Good information ❤❤

  • @teachersforum5192
    @teachersforum5192 2 месяца назад +1

    Good

  • @mjanmjan1803
    @mjanmjan1803 Год назад +1

    Excellent

  • @masifkhan4999
    @masifkhan4999 6 месяцев назад

    ماشاءاللہ

  • @engafghan2738
    @engafghan2738 6 месяцев назад +2

  • @abdullahjutt6993
    @abdullahjutt6993 Год назад +1

    Nice 👍

  • @alamsher4398
    @alamsher4398 Год назад

    Very nice

  • @abdulmannan1722
    @abdulmannan1722 15 дней назад

    good ❤

  • @marsalan4982
    @marsalan4982 11 месяцев назад +2

    Dear sir .kindly 2/3 question hain
    1 is .ye 7/11 ya 5/7 etc vfd ka kya mtlb h
    2. Kya hr vfd 3 phase hoti hai? Us py single phase chala skty hain?
    3.ghar ki 220v item run krny k leay vfd k sath koi asi chez jis se ghr ka load chalaya jay or chezen khrab na hn.
    4. Vfd start time py frequency low to high ho k adjust velu py ja k stable ho jati.kya dhoop km hony ki wja se frequency km ho gi ya voltage km hongy ???? Plz guide sir

  • @daudtahir7130
    @daudtahir7130 4 месяца назад

    Thanks

  • @ghulamhussainzardari4138
    @ghulamhussainzardari4138 Год назад +1

    Sir market mai hybrid vfd ai hai un ka information dai plz

  • @arsalanyaqub
    @arsalanyaqub Год назад +2

    Can we deploy VFD at home for motors ?

  • @abidazadarinetwork
    @abidazadarinetwork 5 месяцев назад

    بہترین . سر گھر والی موٹر, واشنگ مشین وغیرہ پر VFD لگا سکتے ہیں

    • @SmartSolar1
      @SmartSolar1  5 месяцев назад

      Nahi sir vfd tubewell system k sath lagti hy ghar me inverter use huta hy

  • @mazharmazhar4492
    @mazharmazhar4492 Год назад +1

    Mazhar Rana Kuwait

  • @aurangzebkhan8292
    @aurangzebkhan8292 Год назад +1

    Can we use vfd for 2 HP AC motor for home extracting water from 100 feet depth. How many solar panels and what vfd would be required?

    • @SmartSolar1
      @SmartSolar1  Год назад

      Contact us at 0311-4011444 for details

  • @abdulrazzaq5072
    @abdulrazzaq5072 Год назад

    What is better for domestic 2 hp missile motor, vfd or inverter ?

  • @homeoherbalproductsreview
    @homeoherbalproductsreview 11 месяцев назад

    Magar humaray friend to vfd ki madad sy AC chlatay hain, or wo bhi bghair batteries k.

  • @AbdulWahab797
    @AbdulWahab797 7 месяцев назад

    Can I use volt protector for home appliances?

    • @SmartSolar1
      @SmartSolar1  7 месяцев назад

      Yes sir you can use the voltage protector device for home appliances.

  • @noorawan6267
    @noorawan6267 Год назад

    Tokia masheen chl sktee han

  • @mudsirsaeed382
    @mudsirsaeed382 3 месяца назад

    Do invertor same panels pr laga sakty hain

    • @SmartSolar1
      @SmartSolar1  3 месяца назад

      Kindly sir contact us on whatsapp for further detail 03114011444

  • @user-ry7fr5wp9v
    @user-ry7fr5wp9v 4 месяца назад

    VFD laga kr uski output per staiblizer conect kr dy uski output achi aygi ?

    • @SmartSolar1
      @SmartSolar1  4 месяца назад

      Vfd aur panels inka kaam hy

  • @maftabk
    @maftabk Год назад

    That means VFT should be used for water motor in homes and inverter for rest power requirements. Please clarify. Thanks

  • @nasirsiddique1747
    @nasirsiddique1747 2 месяца назад

    Can we install VFD on single phase motor?

  • @tallalahmedkhan9799
    @tallalahmedkhan9799 Год назад

    I am very confused and shucked in a huge problem of inverter sizing and solar panel sizing.
    Kindly answer to my Question.
    Question: We have 1 HP AC 3phase Motor and we want to calculate how much solar power and inverter size we required?
    1 HP=746 Watt
    Current it draws during running condition 3.39 Ampere
    Starting current 1hp of motor requires 3.39*6=20.34 Ampere
    If we design Solar System at 746 watt with 3.39 Ampere then with safety factor of 1.35 we need almost 1100 watt of panels
    and these panel cannot provide 20.34 Starting current to Motor . Inverter may switched off flickered....
    now to start Motor we need 20.34 Amperes . what to do in this case should we design and calculate our system on starting current ?
    Starting Power= 220*20.34=4474 watts
    Solar Panel we required =4474*1.35= 6040watts
    It is blowing my mind that to provide starting power to a motor we need to install 6500 watts of Solar system for just 746 watt of motor.
    If this is not So, Kindly tell me how motors achieve starting current of 20.34 Ampere with 1100 watt of solar panels.
    Kindly Answer this i know every thing about solar designing just this point is confusing me alot and I am shucked at all.
    And tell me which power starting or running power we will consider in designing phase of inverter and solar panel calculation?
    It is also blowing my mind that people are running smoothly 746 watt of motor on 1100 watt of solar panel without any problem but how ? The logic behind it is confusing me because AC, Refrigerator ..heavy loads required high amount of current
    If we have AC, Refrigerator, Water Pump Motor, Led Bulbs ,TV At home ..what to do in this case you said we cannot use hybrid for motor. we have water pump at home with other loads..what to use in this case ?

    • @SmartSolar1
      @SmartSolar1  Год назад

      ok sir this is our contact no 0311-4011444 for details.

    • @razikhan8927
      @razikhan8927 9 месяцев назад

      Insert a VFD between Solar Power and Motor. 3 kVA System is sufficient. The initial current issue would be handled by VFD by providing small current initially and then gradually increase it. Rest house eqpt shall run on normal inverter.
      VFD is reqd if your inverter failed to run the motor properly.

  • @abdullahqayoomabdullahqayu9607
    @abdullahqayoomabdullahqayu9607 Год назад +1

    Sir, 5 Kw VFD DC Ketne Ampere Letee Hai ? halaaqe Us Me 34 Solar Plates Hote Hain

    • @SmartSolar1
      @SmartSolar1  Год назад

      Kindly whats app at 0311-4011444

  • @technologymania8553
    @technologymania8553 Год назад

    Salam Bhai 1.5hp ki motor agr 5.2kw ke inverter per chalaen to kia ho ga.??

    • @SmartSolar1
      @SmartSolar1  Год назад

      Thank you so much for reaching out to us . Kindly contact at 0311-4011444 for details .

  • @TheConceptAcademy
    @TheConceptAcademy Месяц назад

    i have invt VFD for home.

  • @javeediqbal5000
    @javeediqbal5000 3 дня назад

    Vfd sy moter km bijle pr slow chalte rhhte hy jb wapda ke bijle km hote hy to moter kuen nhe chalte?

    • @SmartSolar1
      @SmartSolar1  3 дня назад

      Kindly sir contact us on whatsapp for further detail 03114011444

  • @muhammadahmedjamil6975
    @muhammadahmedjamil6975 3 месяца назад

    Kia Volt Stablizer Ki VFD k sath laga kar Ghar ka load chalaya ja sakta hai?

    • @SmartSolar1
      @SmartSolar1  3 месяца назад

      Ni sir inverter lazmi huta hy solar system mein

  • @malikwaqas1293
    @malikwaqas1293 10 месяцев назад

    آپ نے جتنا کچھ بتایا اس سے میرا کنسیپٹ کلیئر نہیں ہوا ،
    میرا ایک سادہ سا سوال ہے کہ 4.5 kw کی آؤٹ پٹ والے انورٹر پر 3hp کا submersible water pump چلایا جا سکتا ہے یا نہیں ، اگر نہیں تو کیوں نہیں ؟؟

  • @muhammadtahirnawazofficial7806

    Sir vfd ma sath single face shring ho jatti ha kia

    • @SmartSolar1
      @SmartSolar1  Год назад

      Thank you so much for reaching out to us . Kindly contact at 0311-4011444 for details .

    • @pervaizkhan6546
      @pervaizkhan6546 Год назад

      سر وی ایف ڈی. میں ساتھ سنگل فیز شئیرنگ ہوجاتی ہے

  • @alirazamojmasti0074
    @alirazamojmasti0074 3 месяца назад

    Matlab k agar is k agay bara stablisar laga lain to wo voltage pory kar day im right.

    • @SmartSolar1
      @SmartSolar1  3 месяца назад

      Kindly sir contact us on whatsapp for further detail 03114011444

  • @studentsactivitieschannel8899
    @studentsactivitieschannel8899 Год назад

    میرا فرونس 4.2 انورٹر دونوں فیز دے رہا ہے جس کی وجہ سے فریج کام نہیں کرتا.. کیا کوئی بتا سکتا ہے کے دونوں اطراف میں فیز کیوں آرہا ہے

  • @naveedahmad4327
    @naveedahmad4327 Месяц назад

    اسلام علیکم سر جی vfdبغیر سولر کے بھی لگای جاسکتی ھے آٹا چکی پر

  • @UsmanAli-mq2js
    @UsmanAli-mq2js 3 месяца назад

    سرہماری آٹا چکی ہے 15کی موٹر ہے اور555والے 26پینل ہیں کون سا اور کتنی پاور والا انورٹر لینا چاہیے

    • @SmartSolar1
      @SmartSolar1  3 месяца назад

      Kindly sir contact us on whatsapp for further detail 03114011444

  • @qaiserghouri6055
    @qaiserghouri6055 3 месяца назад

    Wapda se vfd attach ho jati ha

  • @user-ki5wj6mm2c
    @user-ki5wj6mm2c 3 дня назад

    میں شنگل فیز موٹر 300 فٹ گہرائی پانی کیلۓگہراہی سے پانی لے رہا ھوں (چوہا موٹر) سولر کیلۓ دھوپ کبھی کبھی ناکافی ھوتی ھے -5 1 ہارس پور دھوپ نہ ھو تو بجلی پر چلانی ھو گی سولر کیسے ایڈجسٹ میں موٹر سنگل فیز ڈیڑھ ہارس پاور ھے

    • @SmartSolar1
      @SmartSolar1  3 дня назад

      Kindly sir contact us on whatsapp for further detail 03114011444

  • @bakhtawarshah8282
    @bakhtawarshah8282 Год назад +1

    سر میں تو vfd پر گھر کے تمام اشیاء چلاتا ہو یہاں تک کہ الیکٹرک پریشر کوکر بھی لیکن سر کیا میں اس پر مائکروویو استعمال کر سکتا ہوں مہر بانی کر کے جواب دیں۔

    • @Whitestonetahir
      @Whitestonetahir Год назад

      Vfd pe sirf motors chalti hain yeh speed control device hoti hy jaise fan m dimmer kaam krta hybissivtrah vfd motor m.
      Jb k invt dc to ac k liye use hota hy

    • @gulfammehmood5037
      @gulfammehmood5037 9 месяцев назад

      ​@@Whitestonetahirhelo

    • @sayedwaheedalinaqvi2064
      @sayedwaheedalinaqvi2064 Месяц назад

      Kia vfd per china ups chala sakty hain

  • @user-te8ih4lp9m
    @user-te8ih4lp9m 11 месяцев назад

    VFD lagging in corner 😂

  • @zakirhussain9968
    @zakirhussain9968 Год назад +4

    سر میرے پاس ایک سو پچاس واٹ کی تین سولر پلیٹ ہے بغیر بیٹری دن میں صرف موبائل اور وائی فائی راوٹر چلانا ہے تو اس کے ساتھ کیا لگانا چاہےرہنمائی فرمائیں

    • @SmartSolar1
      @SmartSolar1  Год назад

      Thank you so much for reaching out to us . Kindly contact at 0311-4011444 for details .

    • @ch_shahid577
      @ch_shahid577 Месяц назад

      Mini car inverter 1000w laga lo agr bettry hai ap k pass to

  • @walisalman786
    @walisalman786 Год назад +2

    سوال یہ ہے کہ جب انورٹر پر میکس ڈی سی وولٹ اور ائمپیر لکھے ہوتے ہیں تو میکس input PV کیوں لکھا ہوتا ہے ؟ مثلاً 1000 واٹ کے انورٹر پر ہم 3000 واٹ کیوں نہیں لگا سکتے انورٹر کی وولٹ اور ائمپیر کی رینج میں رہتے ہوئے ۔

    • @awaistajamal9824
      @awaistajamal9824 Год назад

      jab hum 1000 watt k invertr pay 3 hazar watt ka load lgaye gy
      jb k volt or amp invertr k range m.hain
      tu wohi invertr os 3 hazar waatt k load ko chalany ki koshish kry ga lekin.oska load zyada hoga jo invertr k.andr electronic system.lga hai jo.components lagy hai wo.1 hazar watt tak k load ko chalany k liye lagy hoty isliye 3 hazar ka jaisy load dalanin gy wo.burn ho jaye gu

  • @angaarkhan5749
    @angaarkhan5749 Год назад

    ویلڈنگ مشین کو سولر پر کیسے چلایا جا سکتا ہے؟کیونکہ ویلڈنگ مشین سٹارٹ میں بہت زیادہ کرنٹ لیتی ھے۔
    400 واٹ کی مشین ابتدائی سپارک میں 6 کلو واٹ تک پاور لے لیتی ھے۔ تو کیا ایک لوہار سولر سسٹم سے استعفادہ نہیں کر سکتا؟

  • @faizurehman2464
    @faizurehman2464 Год назад

    Bkwas

  • @shoaibalamkhan21
    @shoaibalamkhan21 Год назад +2

    Nice #shoaibelectronicstech

  • @dawat-e-fikar4204
    @dawat-e-fikar4204 19 дней назад

    Good

  • @hafizabid7928
    @hafizabid7928 Месяц назад

    Good