    @abdauamranal-kautsar9809 Год назад

    How to set temperature to keep same as set value? My modul keep overshoot the sv

    • @AutonicsCorp
      @AutonicsCorp  Год назад

      Basically, it is recommended to use [Auto tuning] after setting the SV.
      If the problem continues even after [Auto tuning], set the P(Proportional band) value larger than before.

  • @jahidhasan0904
    @jahidhasan0904 Год назад

    How to set Auto tuning settings?

    • @AutonicsCorp
      @AutonicsCorp  Год назад

      To perform auto-tuning, the temperature sensor and heater must be connected.
      After setting the SV, please set the [At] parameter of parameter group 1 to [ON].
      The temperature controller calculates and stores the PID values after performing temperature control twice based on the SV reference.

  • @mohammadsutarjo2303
    @mohammadsutarjo2303 4 года назад

    Mhn terjemahan bhs indonesia