  • Learn how accumulator works. The BOP control unit consists of accumulator bottles, a reservoir tank, a charging system to pump hydraulic fluid into accumulator bottles, pressure regulating valves, an operating manifold, pressure relief valve, pneumatic pressure transmitters, and air junction boxes. The purpose of the BOP control unit is to provide pressurized hydraulic fluid that will promptly operate the blowout preventers. The BOP control unit consist of at least one electric pump and two or three air pumps. Its purpose is to pump hydraulic fluid into the accumulator bottles. The sizing of the pumps depends on the volume required to be pumped into the accumulator bottles. With the number of pumps available in the unit, the system should be charged within 15 minutes. As
    per API, with accumulators are isolated, each pump system should be capable of closing annular preventer, opening one HCR, and provide the operating pressure level recommended by the annular BOP manufacturer to effect a seal within 2 minutes. Before commencing a visual inspection, ensure power to the electric pump and air supply to the air pump is turned off.
    Electric Pumps The guard which covers the chain or belt & connects the motor to the pump, sometimes vibrates & becomes loose and should be secured. Routine maintenance includes checking of oil level in pump & crank case, chain guard, and cleaning of filters. A hydro-electric pressure switch is connected to the electric pump which starts the pump automatically when the pressure drops below 90% of unit rated working pressure & stops the pump when the rated working pressure is reached. The cut-off limit of the pump can be increased or decreased by adjusting the screw provided in the pressure switch. In normal operation, the starter switch should be in Auto mode.
    Air Pumps
    Check the condition of the air filter and lubricant. Ensure that the lubricator contains a sufficient amount of oil. Inspect the condition of the air line running into the pumps and ensure that the high-pressure discharge lines are secured to the control unit. The suction filter should be cleaned periodically. This provides an opportunity to assess the condition of hydraulic fluid by exposing the type of contaminant present. A hydropneumatic pressure switch is connected in the air line to automatically shut off the air pump when desired accumulator pressure is reached. The cut-off limit of the air pump can be increased or decreased by adjusting the spring compression by tightening or loosening the adjusting nut provided in the pressure switch.
    5.10.1.6 Pressure Regulating Valve (Regulators) The BOP control unit comprises two regulators; one is a manifold regulator which regulates the accumulator pressure from zero to 1500 psi and in some units from
    Zero to 3000 psi. The downstream of the manifold regulator is connected to a bypass valve and from there to an operating manifold. Manifold pressure operates all the functions except annular preventer in BOP stack. Another regulator is for annular preventer which regulates accumulator pressure to operating pressure of the annular preventer from zero to 3000 psi.
    RigWorld Wellcontrol Training Manual

Комментарии • 29

  • @peacefulwithin7289
    @peacefulwithin7289 5 месяцев назад +1

    Never had anyone,even the books explained the working of this system so well. Thank you

  • @80yash
    @80yash 2 месяца назад

    Nicely explained sir. Thanks for the video.

  • @pradeepsinghkarki1540
    @pradeepsinghkarki1540 3 месяца назад

    Best video every oil field person must watch this..... love the way you explain everything sir ... Plz explain solid control equipments also like that...

  • @johnogwumike2860
    @johnogwumike2860 Год назад +1

    Great! A very thorough and clear teaching.

  • @ramprashadsanase1592
    @ramprashadsanase1592 3 года назад +3

    Thank you so much. Very clear explanation!

  • @nitin2067
    @nitin2067 4 месяца назад

    Thank you sir

  • @radhakrishan4406
    @radhakrishan4406 Год назад +1

    Great to learn from this video. Thank you so much.

  • @Trendingpower213
    @Trendingpower213 3 месяца назад +1

    Good morning sir can you explain about of shear operation during well blow out......

  • @alihameed6612
    @alihameed6612 Год назад

    Thank you so much. Very clear explanation

  • @ricardosaulombo8484
    @ricardosaulombo8484 Год назад

    Thanks for your explaination sir keep doing good job

  • @aqeelrabbani1388
    @aqeelrabbani1388 Год назад

    Very nice explanation sir thank you so much

  • @aatishchouhan9374
    @aatishchouhan9374 11 месяцев назад

    Very detailed video 👏👏

  • @mithifun5361
    @mithifun5361 3 года назад

    Such as you great sir

  • @osmanokyay8429
    @osmanokyay8429 Год назад

    Excellent

  • @user-zk6wx1ek6f
    @user-zk6wx1ek6f Год назад

    Thanks for the detailed information. Can you also share the Accumulator Electrical Charging Working video? As I found the Accumulator Pneumatic charging working video.

  • @mosinholic2695
    @mosinholic2695 Год назад

    Whats the procedure during ram change? Do we need to isolate the banks? Or keep it open?

  • @inderjeethooda3710
    @inderjeethooda3710 2 года назад

    When I close a bop and put the 3p4w valve in neutral , and suppose a kick occurs, will it open ?

  • @wadahahmed7207
    @wadahahmed7207 Год назад

    👏👏

  • @jillbuntagna
    @jillbuntagna 3 года назад

    Sir if BOP has closing ratio of 10.56:1 with BOP class 5 A1-R4 15K BOP. can you make any video for usable fluid on this one when closing all annular and rams.

  • @inderjeethooda3710
    @inderjeethooda3710 2 года назад

    What is the purpose of selector valve as 3P 4W valve , sir ?

  • @acquirean
    @acquirean 2 года назад

    At 08:03 neutral position has been mistakenly depicted wrong way. In neutral position ,Ports are locked and disconnected rather than directed to drain . Correct me if I am wrong.

    • @AjayVermaErigworld
      @AjayVermaErigworld  Год назад

      MANIPULATOR AND SELECTOR VALVES
      All these valves are 3-position 4-way valves. When a manipulator or selector valve is kept in open position, the pressure port gets connected to open port and drain port gets connected to close port. When these valves are kept in close position the pressure port gets connected to close port, and drain port gets connected to open port. When a manipulator valve is kept in Block(neutral) position the open and close ports get connected to drain. When a selector valve is kept in Block(neutral) position all the four ports get isolated.
      Sorce

  • @cocktailunlimiteddemow1657
    @cocktailunlimiteddemow1657 2 года назад

    Thank you so much sir.. But you dint explained the bypass

  • @muhammedsalih3262
    @muhammedsalih3262 2 года назад

    Our accumulator is 5000 Psi

  • @talibturki5612
    @talibturki5612 2 года назад

    Sir please gime me pdf please

  • @Devarshgaming2013
    @Devarshgaming2013 2 года назад

    Dear sir when I charged accumulator upto 3000 psi then it's goes down to 2700 psi without any operation but after then it's remain keep hold 2700 psi please guide me this issue

    • @thinaharran
      @thinaharran 2 года назад

      It should still drop but there could be a leak in the system. Did the electric pump cut in to charge it back up again? Depending on your cut in of the electric pump, it should charge to the max system pressure.