Olá, bom dia. Tenho uma bomba submersa ebara de 4 polegadas a uma profundidade de 55 metros. Ela está instalada com caixa contol box da bomba e com sensor de nível coel. Ela liga normalmente, mas quando a agua baixa dentro do poço ela fica ligando e desligando simultaneamente dando tranco hidráulico na tubulação. Sabe me informar como resolvo isso? Pedro, obrigado.
Thanks for taking time to post a video. You forgot the pressure switch. If one was to wire a system as you have shown it could cause serious injury as well as damage to the pressure tank.
Dear sir i have installed 2hp submercible pump 8 month ago. I received heavey bill of electricity then i check the amp of motor if is drwaing 23 amp. As per my knowledge i should draw max 1amp kindly guide me.
how many watt is your submersible pump? i think your submersible pump is amp problem you please check your local electrician. Thank you. please subscribe this channel
That pump has a manufacturing default because the amparage supposed to be in the range of 9 to 10 amps, i had the same problem , 1. Maybe the pump has frictions between the rod and the impellas kindly dismantle the impellas and check if yes put washers. 2. The pump mighty have sacked sand or stones thats the one that is causing the friction. 3. Check the poly pipe maybe it has leakages that may keep the pump runing all the time. Also test the pump from out side to check whether the impellas are not sucking air in between them
Antes de subir el video deberías de investigar, amarillo no es earth al menos aquí en los estados unidos, es neutral caliente que adquiere voltaje y es el que corre con máximo amperios que los otros cables ya que los otros colores comparten un “relay” cable a tierra aquí es verde o cobre sin cubrimiento rara vez gris y neutral es blanco..
On my 3hp pump, the control box that comes with it has four wire connections and is wired this way but the plug coming out of the box is 110v. So does this mean the capacitor kicks on the 220v pump but it runs on 110v?
O video muito, mais infelizmente não é preconceito nem politico nem nada mais entrar propaganda política num video desse é complicado infelzmente não compactuoo com essas propagandas, são 3 coisas: POLITICA, RELIGIÃO E FUTEBOL, quando voces fizerem seus vídeos peçam para não propagar essas 3 desvangatens que denigre seu vídeo.........ATE TIREI O LIKE QUE FIZ por cooerencia indevida desses canais de propaganda quem saiu perndeno foi voce.......valeu colega
@@JrElectricSchool আপনি কোন সফটওয়্যার দিয়ে তৈরি করেন। বা ওই জিনিসগুলো কভার কিভাবে পান। যেমন সুইচ সকেট ইন্দিকেটর বেকার এবং সেগুলো কিসের সাহায্যে তৈরি করেন। তা আমাকে দেখিয়ে দিলে ভালো হবে।
Borewell depth is 335 feet. overhead tank is on the 4th floor home, roughly 50 feet height. What hp/stage motor please? Please also clarify water flow. Does it need to go from borewell to underground sump and then sump to overhead tank? How can same submersible motor/pump do both? What is function of starter/panel in this apart from starting motor?
Esas madres se la kitan dejan directo los cables no conectaan las protecciones.por que cuando es grande el corto ciryo consumo de corriente esas protecciones jamás abren y el motor se lo lleva la mierda. No tiene sentido conectar las protecciones
Very nice video i am syed alam from pakistan
Thank you very much
Exelente explicación 👍
Please avoid music background I like you video thanks
i will try
Thank you so much
অনেক ধন্যবাদ।।অনেক সহজ ভাবে বোঝানোর জন্য।।।
Thank you so much
Thanks for the video...upload more please
I will try my best
Olá, bom dia. Tenho uma bomba submersa ebara de 4 polegadas a uma profundidade de 55 metros. Ela está instalada com caixa contol box da bomba e com sensor de nível coel. Ela liga normalmente, mas quando a agua baixa dentro do poço ela fica ligando e desligando simultaneamente dando tranco hidráulico na tubulação. Sabe me informar como resolvo isso? Pedro, obrigado.
Very nicely diagrammed.
thank you
You are welcome
@@JrElectricSchool I would love to learn more
@@mathewsnyirenda4004 please subscribe our channel for more videos. Thank you
Hi bro share me your number
Thank you so much for this channel
This is good.you have life easy for me
Thanks 👍
Welcome 👍
Good for electricians.
অনেক অনেক ধন্যবাদ
In your connection the life is connected to capacitor while I have seen a tutorial also but the life is connected to the overload
Thank you
মাশাআল্লাহ ভাই এই ভিডিও আমার ওনেক উপকার হইছে আপনাকে ধন্যবাদ ভাই
Great video
Thanks!
Muy buena gráfica 🔥🔥🔥🔥🔥
De
I love it
Hola amigo muy bun video te paso a preguntar si no usas el termico y lo remplazas por un relay como seria su conexcion
Thanks for taking time to post a video. You forgot the pressure switch. If one was to wire a system as you have shown it could cause serious injury as well as damage to the pressure tank.
Good 👍👍👍👍👍
Thanks👍
Common is neutral . We don't need 4 wire only three wire but sometimes 4th wire is used for ground
yes your right sometimes ground wire is used.
Thanks for watching
Thanks ❤️❤️❤️
You're welcome 😊
Dear sir i have installed 2hp submercible pump 8 month ago. I received heavey bill of electricity then i check the amp of motor if is drwaing 23 amp. As per my knowledge i should draw max 1amp kindly guide me.
how many watt is your submersible pump?
i think your submersible pump is amp
problem you please check your local electrician.
Thank you. please subscribe this channel
That pump has a manufacturing default because the amparage supposed to be in the range of 9 to 10 amps, i had the same problem , 1. Maybe the pump has frictions between the rod and the impellas kindly dismantle the impellas and check if yes put washers. 2. The pump mighty have sacked sand or stones thats the one that is causing the friction. 3. Check the poly pipe maybe it has leakages that may keep the pump runing all the time. Also test the pump from out side to check whether the impellas are not sucking air in between them
Awsome bro more use full ur videos
Ok thank you
szxh7scfx
Tnx bro
you welcome
Yes condensor motor capacitor makes 90 degrees lead curent .
I hanve supprised cause of same as my country I have learned.
Thanks for watching
Nice
Thank you
Every submercible pump for bore well has red yellow blue no black wire. Wrong video
you have a good look at everything moreover color does not matter
My 4” Franklin Electric Deep Well Pump 3 - Wire Has BLACK / RED / YELLOW
+ GREEN Ground
there is black
Pumps don't have wiring, motors do.
Well mine has 4 earth, blue,brown, black.
1 submersible Pump/motor ko 2 ya 3 jaghe se control/operate kare?
Disculpen donde puedo conseguir los botones de ensendido de la bonba sumerjible truper de 1" porfavor gracias
good
Thanks
Thanks
Good luck 👍
Thanks 👍
please subscribe this channel
Thank you so much 🙏🙏
You're most welcome
Hola, hay forma de comprobar la bomba sin el panel. Gracias
You are amazing man
Thank you
What I need is 3 phase motor 440 volts with heater and thermostat control,35kw
Good
Thank you so much
please subscribe this channel
👌
Great sir g
Thank you so much
please subscribe this channel
Aq o meu desse n fica armado por MT tempo, relé desarma ,oq pode cer?
sorry i am not understand your language
please tell Bangla Hindi English.
Thank you
So, is the yellow wire ground??
yes
Nice warring
Thank you very much
Tnq
nice
Thank`s for watching this video
please subscribe this channel
Sir g ups k sath connection kese kre
Ups kitne watt Ka hona chahye
o ape ka motor ke opor depend karte he ape ka motor ketne watt ka he
@@JrElectricSchool sir ups 1.2 kV Ka he aur missile motor 1HP ki he
A small correction positive should be connect with capacitor running point but you connected to starting point by mistakenly.
no problem its ok
excelente video una pregunta el condensador es de trabajo o de arranque?
Thanks a lot
Antes de subir el video deberías de investigar, amarillo no es earth al menos aquí en los estados unidos, es neutral caliente que adquiere voltaje y es el que corre con máximo amperios que los otros cables ya que los otros colores comparten un “relay” cable a tierra aquí es verde o cobre sin cubrimiento rara vez gris y neutral es blanco..
Supongo que el verde es tierra.
Automatic phase change over system video podunga
i will try very soon
Thank`s please subscribe this channel
nic
Thanks for watching
On my 3hp pump, the control box that comes with it has four wire connections and is wired this way but the plug coming out of the box is 110v. So does this mean the capacitor kicks on the 220v pump but it runs on 110v?
O video muito, mais infelizmente não é preconceito nem politico nem nada mais entrar propaganda política num video desse é complicado infelzmente não compactuoo com essas propagandas, são 3 coisas: POLITICA, RELIGIÃO E FUTEBOL, quando voces fizerem seus vídeos peçam para não propagar essas 3 desvangatens que denigre seu vídeo.........ATE TIREI O LIKE QUE FIZ por cooerencia indevida desses canais de propaganda quem saiu perndeno foi voce.......valeu colega
ভাই আমি কী আপনার সাথে কথা বলতে পারি
yes! how can i help you
@@JrElectricSchool ভাইয়া আপনি কিভাবে ওই ভিডিওগুলো তৈরি আমাকে একটু শিখাবেন। আমাকে শুধু কিভাবে এডিট করেন তা শিখাইলি হবে
@@IsmailPointPresident a rokom video banate caile apnake animation jante hobe
@@JrElectricSchool আপনি কোন সফটওয়্যার দিয়ে তৈরি করেন। বা ওই জিনিসগুলো কভার কিভাবে পান। যেমন সুইচ সকেট ইন্দিকেটর বেকার এবং সেগুলো কিসের সাহায্যে তৈরি করেন। তা আমাকে দেখিয়ে দিলে ভালো হবে।
ilan uf sir ang dpat ilagay sa 7.5 hp ?
How do I connect a single float switch to two different tank?
Borewell depth is 335 feet. overhead tank is on the 4th floor home, roughly 50 feet height. What hp/stage motor please? Please also clarify water flow. Does it need to go from borewell to underground sump and then sump to overhead tank? How can same submersible motor/pump do both? What is function of starter/panel in this apart from starting motor?
Pourquoi le relais d'intensité se déclenche tout le temps
What happen if the red cable change with black cable ?
Or red with blue cable ?
Berapa harga nya bos ku
Control is ok
What if I want to add floating switch
Single phase motor connection
it is submersible single phase motor connection
Thank you
makasi infonya
sorry i am not understand
please Bangla,Hindi,English
Ami apnar moto video banano sikhte chai amake sikhaben
Quiero que por favor me recomiende una bomba su marca sumergible soy dominicano
how many uf for 7.5hpmotor?
Magistral gracias mil
How much is the capacitor capacity of the submersible
10 micro Farad
como ligo a bóia automática superior
Esas madres se la kitan dejan directo los cables no conectaan las protecciones.por que cuando es grande el corto ciryo consumo de corriente esas protecciones jamás abren y el motor se lo lleva la mierda.
No tiene sentido conectar las protecciones
Why does it need a capacitor?
It's a single phase... to increase the starting torque bt if it is three phase there's no need to connect capacitor
Sir can you regulate the speed of submersible pumps
i will try to make video on your topic
Thank you
ভাই আমার মটরের পানির গতি কম পানি কম উঠে এটার সমাধান কি,,
আপনি কত পয়েন্টের তাঁর দিয়ে মটর চালান।
Jalur singkat saja
Porque mi bomba trabaja 2 minutos y se bota el fucible
We need volcans backery system
Thanks for watching
BLUE? Is this a non-USA schematic?
Running
Is there an adult version of this?
Faltu
Bakwash
Supongo E es tierra fisica
Good
Thanks