Liquid Penetrant Testing

Поделиться
HTML-код
  • Опубликовано: 3 июн 2024
  • ХоббиХобби

Комментарии • 95

  • @abc6312
    @abc6312 Год назад +9

    If provide more close-up pictures for all indications on the second test plate, it will be great.

  • @arvindnavinsv2227
    @arvindnavinsv2227 3 года назад +3

    thanks man you did a great job explaining, i am gonna show this to my student for easy understanding

  • @sv7382
    @sv7382 9 лет назад +1

    Great demonstration Robert. Mike told me the story behind the test plate. Sneaky!

  • @wizyasilupumbwe2497
    @wizyasilupumbwe2497 7 лет назад +1

    thanks am actually writing an end of term essay on this, cleared alot of things up thanks.

  • @writer1meb
    @writer1meb 7 лет назад +4

    Thank you. This video is very helpful. We didn`t know before watching this video how to use liquids.

  • @dan-xl4mg
    @dan-xl4mg 2 года назад +18

    this is so much easier to understand then my teachers explains it in front of 30 students, so thank you for this amazing video, I will definitely recommend this to the other students.

  • @georgevitor6975
    @georgevitor6975 3 года назад

    After mechanical cleaning ( example wire brushing,grinding,buffing) of part to be tested,is cleaning of part by means of cleaner/remover still necessary?or it can be skipped and apply penetrant already?

  • @ptrangdang
    @ptrangdang 7 лет назад +2

    very clear. well-done. thank you

  • @FacetiousUniqueness
    @FacetiousUniqueness 7 лет назад

    Excellent Video! Thanks!

  • @kmondak3387
    @kmondak3387 7 лет назад +8

    Should have tilted the plate to do away with glare and let the viewer see. An intentional crack in the plate would have been good for checking engine heads etc.

  • @marcodiegocambronerovillal7647
    @marcodiegocambronerovillal7647 3 года назад +9

    Me studying, getting asmr vibes from this lmao

  • @finessedagain4557
    @finessedagain4557 4 года назад +1

    You are an absolutely legend, I hope you know that pal

  • @planetbeatmobb1762
    @planetbeatmobb1762 8 лет назад +8

    great job, we were taught to spray the developer away from the metal first to make sure it's fully agitated tho?

    • @ifaheemonline
      @ifaheemonline 8 лет назад

      +Planet Beat Mobb Yes you are right. it ensures the uniform spray of developer.

  • @yuvrajbhatt1050
    @yuvrajbhatt1050 6 лет назад +3

    It was nice illustration of the whole process. Can u tell which cleaner, dye & developer you used here?

    • @prasadsawant1213
      @prasadsawant1213 3 года назад +1

      Pmet is one the oldest and leading companies.
      Different products available as per different sizes of cracks

  • @jjjsss3869
    @jjjsss3869 8 лет назад +27

    A close up of the plate with the defects so we could actually see what they look like would have been helpful.

  • @nathanbra8605
    @nathanbra8605 Месяц назад

    If you spray a paint brush with penetrate and brush weld, will that decrease results or is that ok?

  • @DPeter1967
    @DPeter1967 9 лет назад

    Great Jog Robert! Haven't seen you since the New Bay Bridge Project.

  • @dishitapurohit2478
    @dishitapurohit2478 8 лет назад +3

    Can you provide with the product name and specifications of the red spray dye and cleaning sprays you used? also can this be used to test for solders on PC boards

    • @robertmertz7544
      @robertmertz7544 8 лет назад

      +Dishita PUROHIT I would recommend using RT for PC boards.

  • @kalpeshsingh2670
    @kalpeshsingh2670 3 года назад

    How to find out the length of a circular defect whose end is loose? as in not connected?

  • @brettb.7425
    @brettb.7425 5 лет назад +1

    Good demonstration but please get the camera closer to show the details. Thank you for posting this!

  • @Gabby-du4mc
    @Gabby-du4mc 6 лет назад

    Thank you!!

  • @muhammadahsanmehar3265
    @muhammadahsanmehar3265 4 года назад

    Why we are not use to cleaner direct sprey in welding .

  • @adilhafeez5942
    @adilhafeez5942 4 года назад

    Really good explanation thx

  • @rubenrosales7823
    @rubenrosales7823 4 года назад

    Close up of defects?

  • @ezekielmunatsi5496
    @ezekielmunatsi5496 2 года назад

    Very informative, Thank you.

  • @jithinmathewjoseph9465
    @jithinmathewjoseph9465 4 года назад

    can this method be used in pipes

  • @ryanarnold2813
    @ryanarnold2813 7 лет назад

    Very Nice, Well Done !

  • @tradingmachine65
    @tradingmachine65 2 года назад

    make sure cleaner flashes off for correct time, 5 minutes min. old cleaners used to flash much faster. if cleaner remains in crack, inspection is void, if being audited you'll be flagged

  • @The3Shogun
    @The3Shogun 8 лет назад +16

    You must wipe off pentrant vertically or horizontally only. One direction. And way to much developer on your HAZ.

    • @robertmertz7544
      @robertmertz7544 8 лет назад +3

      +The3Shogun You are correct for most PT applications regarding cleaning. I disagree about the HAZ. I suppose I could have masked the area of base metal that was not under inspection but the developer spray covers a large area and cleans off very easy. The procedure I was following allows me to wipe in both directions and as indicated I won't have a lot of non-relevant indications that need to be re-tested. Also, the weld and HAZ are evaluated based on VT after PT so I can wipe penetrant out of U/C, etc. and measure for acceptance. Cracks that are very tight would not be wiped away but may be missed by VT. I could have explained why I was cleaning in both directions. Thanks for the feedback.

  • @riddhisarvaiya5243
    @riddhisarvaiya5243 5 лет назад

    You should clean the plate in one direction. And also apply penetrant and developer in one direction. It is either horizontally or vertically. Not both direction you can use for perfect results.

    • @newmovieschannel1364
      @newmovieschannel1364 5 лет назад

      ya mam absoultly write ...he is not correct because of pentrates also pick out in defects

    • @newmovieschannel1364
      @newmovieschannel1364 5 лет назад

      ya mam absoultly write ...he is not correct because of pentrates also pick out in defects

    • @razvancampean
      @razvancampean 4 года назад

      can you specify where does it say so? in which standard or norm (what page)?

  • @abidsaleemdesconian3528
    @abidsaleemdesconian3528 3 года назад

    Thanks for fine explaination.

  • @nomuplays7487
    @nomuplays7487 Месяц назад

    Why u did to and fro motion which doing solvent removal? It's clearly written in ASME BPVC SEC 5 ARTICLE 6

  • @crackersphdinwumbology2831
    @crackersphdinwumbology2831 6 лет назад +1

    I'm an Air Force NDI technician.
    It's kind of shocking how similar yet different Method C inspections are in the civilian sector. Only 20 minutes of dwell time only using visible dye penetrant! It makes sense though, given its easier, faster, and it's doubtful you need as much sensitivity.

    • @subinperingave9777
      @subinperingave9777 6 лет назад

      Hi..
      I have a doubt.
      Is there any need to do penetrate test on a complete machining part ?

    • @chuckb9595
      @chuckb9595 2 года назад

      That was only 10 min of dwell time.

  • @tanveerahmed3094
    @tanveerahmed3094 7 лет назад +1

    thanks very helpful.

  • @socialhelp5704
    @socialhelp5704 5 лет назад +1

    removing pen
    etrant is only in one direction ... To and fro is not allowed

  • @yacinebenz1349
    @yacinebenz1349 9 лет назад

    great job

  • @malikahmad781
    @malikahmad781 5 лет назад

    superb video

  • @akkusrocks3367
    @akkusrocks3367 3 месяца назад

    Sir penetrant cleaning need to do in one direction , am i right ?

  • @imanebahar286
    @imanebahar286 4 года назад

    great video

  • @raymonddupuis9461
    @raymonddupuis9461 9 лет назад

    Nice video moderately informal though....

  • @adamismail9895
    @adamismail9895 8 лет назад

    super

  • @givenmahlangu1266
    @givenmahlangu1266 4 года назад

    Is Post cleaning necessary ?

    • @rubenrosales7823
      @rubenrosales7823 4 года назад

      Given Mahlangu depends where you are and who you are working for. My preference is to leave clean, unless there are any relevant indications. If there is a defect that is Rejectable I mark up and leave so the welder/QC or whoever is the one you are reporting to may see... I have worked places where they are big on us leaving it clean and also have been places where they just go to next job/weld...

  • @samueljacob6031
    @samueljacob6031 5 лет назад

    thank you sir

  • @hahaclintondix6099
    @hahaclintondix6099 Год назад

    This is definitely Walter white Heisenberg

  • @hectorpaniagua5702
    @hectorpaniagua5702 6 лет назад

    What method is this

    • @spoonbill01
      @spoonbill01 6 лет назад

      Hector Paniagua This is Type 2 (visible ) Method c ( solvent removeable ) Form e ( nonaqueous type 2 visible dye solvent based ) Class 2 solvent ( non-halogenated )

  • @shanwarn3772
    @shanwarn3772 6 лет назад +7

    Hi sir
    good morning
    I'm from india
    i finished NDT Level 2
    i need a job
    did any vacancy is in your factor

  • @shreeramvenkatesan1658
    @shreeramvenkatesan1658 4 года назад

    This guy is really really cool

  • @abdelwahedbanouji2638
    @abdelwahedbanouji2638 7 лет назад

    i wanna learn the liquid penetrant teasting cuz im a radio log i wanna some info about that and i wish if someone contac me for ask him meny thing about liquid and magnet

  • @victornjoku9684
    @victornjoku9684 Год назад

    Why cleaning zig-zag.,? Clean from one side.

  • @srinivasandwarakanathan3822
    @srinivasandwarakanathan3822 Год назад +1

    Well explained, But as per standard practice while applying , cleaning pentetrant from the surface we should not wipe or clean bi-directionally. It shall be cleaned only in one direction, the same is applicable while applying penetrant. Hope i am correct.
    Regards
    Dwarakanathan ASNT LEVEL III

  • @user-zf4ov2rs1g
    @user-zf4ov2rs1g 3 года назад

    معهد النجف 😎 يرحب بكم

  • @narendernayakguguloth5018
    @narendernayakguguloth5018 5 лет назад

    Tq sir

  • @itsimzaa621
    @itsimzaa621 Год назад

    Will the fluorescent non-aqueous developer produce better results in evaluating the defects than the visible non-aqueous developer?

  • @ar-1571
    @ar-1571 Год назад +1

    Great video! My teacher played this during class and me and my friends laughed at this because you made it look like a Porn video.. I mean the way you were breathing and cleaning 🤣🤣

  • @kuranenuhaa1880
    @kuranenuhaa1880 Год назад

    Well Explained. Thank you sir, please can u list some examples of the liquid penetrant commonly used

  • @sneakpeek7767
    @sneakpeek7767 2 года назад

    Keep doing

  • @brianb5779
    @brianb5779 2 года назад

    Camera guy afraid to get close. Otherwise good info

  • @redcarpet2544
    @redcarpet2544 2 года назад

    Hello! Thanks for useful video! I have the only one question...Why don't you use a respirator? These sprays are extremely harmful for your health, especially for lungs.

  • @esmeraldaalviso2220
    @esmeraldaalviso2220 2 года назад

    I didn't like it cause a indication in the plate will be better explanation.

  • @chanthasavann
    @chanthasavann 4 года назад

    Hello Guy let mark your Friend too

  • @fahdhanif4150
    @fahdhanif4150 3 года назад

    Watching this just for exam purposes 😑😑😑

  • @mood666
    @mood666 Год назад

    6:00

  • @rmvmedia4897
    @rmvmedia4897 5 лет назад +1

    Wrong apply method

  • @bn70066
    @bn70066 9 лет назад

    hi am NDE man from middle east :))

  • @saqarjamel3383
    @saqarjamel3383 5 лет назад

    Goog

  • @user-bm1jt1jz4o
    @user-bm1jt1jz4o 2 года назад

    CovidImages need to be invested more than half19

  • @TheAjnett23
    @TheAjnett23 4 года назад

    your camera man/women is not so very good..

  • @somnathghosh9873
    @somnathghosh9873 9 лет назад

    Post cleaning is not proper Way..

    • @JavierD
      @JavierD 9 лет назад +1

      Somnath Ghosh why?

    • @somnathghosh9873
      @somnathghosh9873 9 лет назад

      for post cleaning you must clean the surface, from first point to 2nd point you can't clean first to 2nd and again 2nd to 1st. you can clean any of one way 1st to 2nd or 2nd to 1st jv071

    • @chevellecarcass
      @chevellecarcass 8 лет назад

      Somnath Ghosh Post cleaning after the penetrant is applied? What do you mean by 1st to 2nd?

    • @JavierD
      @JavierD 8 лет назад

      ***** 1st point to 2nd point. What Somnath state is that one should clean in the same direction, always right to left (for example)

    • @somnathghosh9873
      @somnathghosh9873 8 лет назад

      yaa you are right