Sir 3 phase system me agr tino Phase ka use single phase ki tarh karte hain matlab sirf lighting and other single phase home appliance use karte hain to yeh to unbalance load condition hai to kya yaha neutral wire same size ka rhe ga ya R Y B wire se double size k rahega plese solve the problem.
Sir electricity bord se 3 phase and neutral supply aati hai or hamare building me single phase ki tarh use hoti hai but tino phase k wire and neutral wire same size ka hi Aisa q Agr har phase me 5 amp current flow ho rah hi to neutral wire me 15 amp current flow hota hoga to neutral wire mota hona chaie . Yahan system to single phase ki tarh use hoara hai to system to unbalance hai yahan koi 3 phase motor to nahi chal rahe hai system balance ho or neutral me koi current nahi flow horaha . To neutral wire mota q nahi hai plese help.
Very nice earthing explane #mtelectricals
Thank you...
Very good information. Thanks
Well explained.👍
Thank you..
Good explanation, thank u
Helpful video
Very nice 👌👌
Thanks sir
Most welcome KK..
Good
Nice video sir
Thank you Rajendra..
Brother can you pls make video on substation earth mat..its construction and other imp details.
Thanks for this video.
👌👌👍
v.nice sir
Sir 3 phase system me agr tino
Phase ka use single phase ki tarh karte hain matlab sirf lighting and other single phase home appliance use karte hain to yeh to unbalance load condition hai to kya yaha neutral wire same size ka rhe ga ya R Y B wire se double size k rahega plese solve the problem.
Thank you sir
Ok
Thank u very very much Ok
Thank u very very much Ok
Thank u very very much
Relay or contactor pr dc load chala sakte hai ya dc load k liye dusra relay or contactor aata hai plz bataye
DC relay aur DC contactor bhi aata hai.
@@electricalwithabhishekjoshi thanks bro
Thanks sir sir agar hamko pipe ke done side par esa kiea dale ki earthing ka oms kam se kam mile plz r jarur batana plz I am waiting sir
Suppobbb sir
Sir electricity bord se 3 phase and neutral supply aati hai or hamare building me single phase ki tarh use hoti hai but tino phase k wire and neutral wire same size ka hi Aisa q
Agr har phase me 5 amp current flow ho rah hi to neutral wire me 15 amp current flow hota hoga to neutral wire mota hona chaie .
Yahan system to single phase ki tarh use hoara hai to system to unbalance hai yahan koi 3 phase motor to nahi chal rahe hai system balance ho or neutral me koi current nahi flow horaha . To neutral wire mota q nahi hai plese help.
Sir please provide relay setting calculation such as Differential, over current, earth fault, over voltage and under voltage etc.
Nice explanation .
Sir , where do we use pipe earthing ? Especially
We have used pipe earthing for Transformer earth pit in our Industry.
Hello Brother ..wat abt static earthing. Also wat abt earthing in hazardous area.
Hum VCB ko maximum kitne baar ON and OFF operation karne ke baad testing karna jaroori hai? Pls answer in brief
It depends on VCB voltage level and other technical specifications. Kindly go through the manual for details.
Sir, how can we protect equipment by earthing?
Sir vfd delta c2000 ka control wiring explain kariye
Help me about dg unit charges by electricity board
Sir electrical drawing kase read karte hai us par ek video banaea
Sar maximum aur minimum resistance Kitna hona chahie?
Sir plate earthing ham substation mai hi kyo karte h
Interview me itni information de de to kafi hoga??
Ye to interviewer pe depend hai ki wo ek topic ko kitna extend karna chahta hai..
Earthing installation k liye contact kare