Hydro test Basic Procedure/ Heat exchanger hydro test/pipe line hydro test/operation/Maintenance/

Поделиться
HTML-код
  • Опубликовано: 21 ноя 2024

Комментарии • 59

  • @vsudhakar8436
    @vsudhakar8436 Год назад

    அருமையான பதிவு. மிக்க நன்றி.

  • @ChandraMohan-qs7hb
    @ChandraMohan-qs7hb 3 года назад +2

    Very usefull points sir.. This week I have hydro test in boiler.. Like this type of videos expecting more.

  • @Theeran_sathya
    @Theeran_sathya 2 года назад

    சிறப்பு... தம்பி.
    நன்றி🙏

  • @saikrishna3977
    @saikrishna3977 3 года назад

    Thanks for making such useful content 😊 love from Andhra Pradesh

  • @funnytime5777
    @funnytime5777 3 года назад +1

    Super bro.. all equipment Shutdown procedure podunga bro itha maari... Once again thanks for detailed info.

  • @ramr7916
    @ramr7916 3 года назад +2

    Good and proper information make more videos bro.

    • @MOHANKUMAR-bz6sg
      @MOHANKUMAR-bz6sg 3 года назад

      Please, share about column shutdown activity

  • @jayamurugans.sevugapandian5613
    @jayamurugans.sevugapandian5613 3 года назад

    THIS IS VERY Useful information.

  • @Manojsmanoj-tj1qc
    @Manojsmanoj-tj1qc 10 месяцев назад

    good sir , can you explain about what types of tools and tackles are using

  • @dillikumar7970
    @dillikumar7970 9 месяцев назад

    Super very useful for knowledge recall

  • @arunkumar-kb5yg
    @arunkumar-kb5yg 3 года назад

    Very useful and informative video bro

  • @sajai_official
    @sajai_official Год назад

    Thank you

  • @lakshmiraghavan6215
    @lakshmiraghavan6215 2 года назад

    Brother Enaku Konjam valve details and safety valve pressure relief assembly difference video venum

  • @FunwithFun-s5f
    @FunwithFun-s5f 3 года назад

    Satisfied brother thanks 🤝🤝🤝

  • @venkadeshmalaxyah6305
    @venkadeshmalaxyah6305 3 года назад +1

    Super info sir

  • @sathishkumarrasu5524
    @sathishkumarrasu5524 3 года назад +2

    psv செலக்ட் பண்ரதுக்கு எதாவது கணக்கு இருக்கா சகோ.எப்டினா 20% அபௌ டெஸ்ட் பிரசர் அப்டி..

  • @cr7saro932
    @cr7saro932 2 года назад

    Anna fitter work irutha solluka anna

  • @RAJKUMAR-qy5rz
    @RAJKUMAR-qy5rz 3 года назад

    Bro planning side ethachi video podunga

  • @sen-ow7ub
    @sen-ow7ub 3 года назад +1

    please make a video about the pneumatic test in lieu of the hydro test for the newly constructed pipe benchmark study?

  • @paramasivan4953
    @paramasivan4953 3 года назад

    9:48 water outlet fittings la rendu value kum middle la thana sir pressure gauge fix pananum ? But ithula appadi illaye sir .clear my doubt sir.

    • @tamilengineeringworld
      @tamilengineeringworld  3 года назад

      we need to avoid the valve gland leak so we provided the valve after the gauge.

    • @paramasivan4953
      @paramasivan4953 3 года назад

      @@tamilengineeringworld ok sir thank you

  • @sadhasivam4455
    @sadhasivam4455 3 года назад +1

    Sir,test ring which type Exchanger used,,,details pls

  • @ldm8484
    @ldm8484 3 месяца назад

    🎉

  • @abdulazizm6517
    @abdulazizm6517 3 года назад

    Bro interview la oru foreman udaya responsible yenna oru hydrotest panradu kku kettaga bro answer please.

  • @abhijithraaghu7831
    @abhijithraaghu7831 2 года назад

    Thank u sir..❤️

  • @stalinn5008
    @stalinn5008 3 года назад

    Bro ithula psv selection eppadi bro design pressure×1.1 ah illa 30 psi ah

    • @tamilengineeringworld
      @tamilengineeringworld  3 года назад +1

      Hi, In this PSV section we are not take any standards. because we need to safety for hydro testing activities,it's tempory arrangement only. if your hydro test pressure 30kg/cm2 means you can used 35 kg /cm2 PSV. our ultimate goal is to secure the equipments.

    • @Harismtk
      @Harismtk 3 года назад

      1.05 times * test pressure

    • @sethunagupasumaipuratchi3346
      @sethunagupasumaipuratchi3346 2 года назад

      Psv we select according test pressure . design pressure is the procedure only not for final...we would select final pressure value for example test pressure 10bar 10×1.1=11...

  • @sivasankars807
    @sivasankars807 2 года назад

    Which type work permit?

  • @sadhasivam4455
    @sadhasivam4455 3 года назад

    Sir wt type valve v use in hydrotest assembly

    • @tamilengineeringworld
      @tamilengineeringworld  3 года назад

      Gate valve

    • @sadhasivam4455
      @sadhasivam4455 3 года назад

      @@tamilengineeringworld can u add hydrotest procedure with codes....

    • @nanisfamily5030
      @nanisfamily5030 3 года назад

      @@tamilengineeringworld how many times we do hydrotest for heat exchanger then how we leak

  • @dheebumadhu279
    @dheebumadhu279 3 года назад

    how it comes both the guage pressure will be same. surely there will be pressure difference in both guages. In fittings pressure guage pressure is more than top guage pressure because of static head pressure

    • @tamilengineeringworld
      @tamilengineeringworld  3 года назад

      Thanks for commenting.. Sir,have you conducted the hydro test in the field?

    • @dheebumadhu279
      @dheebumadhu279 3 года назад

      s

    • @tamilengineeringworld
      @tamilengineeringworld  3 года назад

      Does the QC person accept the pressure difference?

    • @dheebumadhu279
      @dheebumadhu279 3 года назад

      @@tamilengineeringworld if you are hydrotesting a vertical vessel. wheather the two guages pressure same or not

    • @tamilengineeringworld
      @tamilengineeringworld  3 года назад

      if the vessel height is above 10m bottom gauge reading has a difference. but we are discussed with the horizontal heat exchanger only. The exchanger has no pressure difference will come. so don't confuse with exchanger and vertical vessel.
      I only explain the horizontal exchanger and pipeline hydro test procedure in this video.
      10-meter height means bottom gauge reading shows 1 kg/cm2

  • @shahnawazalam8742
    @shahnawazalam8742 Год назад

    Bro upload with English subtitle

  • @mahadhoombasila4333
    @mahadhoombasila4333 3 года назад

    Thank you sir

  • @mageshkumart4362
    @mageshkumart4362 Год назад

    🕶

  • @abdulazizm6517
    @abdulazizm6517 3 года назад

    Bro complete image of hydro test diagram camiga bro.

  • @nagaraj1721
    @nagaraj1721 2 года назад

    👌🙏

  • @DhanaLakshmi-vq2is
    @DhanaLakshmi-vq2is 6 месяцев назад

    99 adandam is 1.3 now 1.5

  • @ArunKumar-ub2co
    @ArunKumar-ub2co 8 месяцев назад

    Enku interview dout na unga number venum na enku

  • @harindarsharma4466
    @harindarsharma4466 3 года назад

    Hinde me video send karo

  • @fredrickmonteiro9689
    @fredrickmonteiro9689 3 года назад

    Good knowledge you give me can you arrange me two heat exchanger technician
    Experience in shell and tube .re tubing and caliprition on tube and make new tube stuck manufacturing knowledge person required. My company in Sharjah UAE.
    Two year agreement with legal labour low in UAE we follow
    Two year after leave .two month leave salary.if person continue after two year salary we pay on WPS

    • @tamilengineeringworld
      @tamilengineeringworld  3 года назад

      Please contact me through email. My Email ID: neelakandan.s13@gmail.com

  • @hussainjan9165
    @hussainjan9165 3 года назад

    Use English dear

  • @PraveenKumar-ry2oe
    @PraveenKumar-ry2oe 6 месяцев назад

    Bro unga contact number venum some doubt

  • @stephenrevino3988
    @stephenrevino3988 3 года назад

    Thanx brother