[English] Hydrotest

Поделиться
HTML-код
  • Опубликовано: 29 авг 2024
  • Hydrotest basic concept explained

Комментарии • 148

  • @vvpk1217
    @vvpk1217 4 года назад +3

    things like air vent, isolation valve, pressure relief valve and selection of gauge well explined.

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @tapasdash1100
    @tapasdash1100 2 года назад

    Very well explained sir. Being a non technical person too I could easily understand the entire thing. Many wishes for your channel.

    • @WeldingandNDT
      @WeldingandNDT  2 года назад

      Thank you. Please join my channel to support me. Joining Link: ruclips.net/channel/UCH7nXSievFlbRKzKzEySbkwjoin

    • @arunkumar-ij8lw
      @arunkumar-ij8lw Год назад

      @@WeldingandNDT sir 10 minutes and 6minute/cm maximum 2hr... Can u pls explain

  • @yasirkhan4743
    @yasirkhan4743 3 года назад +1

    No one can match your quality explanation. ..thank you.

    • @WeldingandNDT
      @WeldingandNDT  3 года назад

      Thank you. Please visit my website www.weldingandndt.com/

    • @AAMIRSHAHZAD1122
      @AAMIRSHAHZAD1122 3 года назад

      @@WeldingandNDT sir channel ko join karny me problem aa rahi ha CSWIP 3.1 ki video kaisy dekhan

  • @humenbot24
    @humenbot24 3 года назад

    Sir, please upload more videos consisting of industrial knowledge. It helps freshers to view and learn for entering the industry. This way we can make our set of knowledge to enter companies and make a better career.

    • @mistermhw
      @mistermhw 2 года назад

      Hi, if you don't mind, please also visit my channel, maybe it can take more information and education

  • @munnakaka3907
    @munnakaka3907 4 года назад

    I'm requesting for you please make this topic and other videos in Hindi language. I'm understanding but my some friends not understand.
    This video knowledge full video.
    Thanks for this.

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Hindi version of all videos are available. Except this topic, which will be uploaded in Aug/Sep.
      Thank you. Please visit my website www.weldingandndt.com/

  • @user-yy6us6rq2x
    @user-yy6us6rq2x 3 года назад +1

    Sir,
    please make a video for the reason of selecting the pressure gauge having the minimum and maximum limit of reading between 1.5 to 4 times of the test pressure .
    Also the capacity of the PSV/PRV with reason.
    Why are two pressure gauge needed ?

  • @haleelimprove
    @haleelimprove 4 года назад

    Super sir.. Watching your videos and also your websites 👍🏻 good work

  • @Infoten_K
    @Infoten_K 4 года назад +1

    Excellent explain sir.. thank you

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @mohammadshabbir7524
    @mohammadshabbir7524 3 года назад

    THANKS SIR VERY GOOD EXPLANATION....KINDLY MAKE MORE...VERY HELPFULL THANKS

    • @WeldingandNDT
      @WeldingandNDT  3 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @manushareddy4707
    @manushareddy4707 3 года назад

    Wonderful video sir.. Thank u

    • @WeldingandNDT
      @WeldingandNDT  3 года назад

      Thank you. Please join my channel to watch all the videos. Joining link: ruclips.net/channel/UCH7nXSievFlbRKzKzEySbkwjoin

  • @harerhdesai5324
    @harerhdesai5324 8 месяцев назад

    Nice presentation 👌

    • @WeldingandNDT
      @WeldingandNDT  8 месяцев назад

      Thank you. Please join my channel to support my initiative. Joining link: ruclips.net/channel/UCH7nXSievFlbRKzKzEySbkwjoin

  • @nirmalsurendranmenon7049
    @nirmalsurendranmenon7049 Год назад

    Tanks undergo Hydro Pneumatic Test. So how is the test pressure calculated for Hydro Pneumatic?

  • @amazingvideos9370
    @amazingvideos9370 4 года назад

    This session is very good
    Plz upload hydrotrst checklist and describe.

  • @adhwaafiq7159
    @adhwaafiq7159 2 года назад

    Easy to understand..thanks for the knowledge.

    • @WeldingandNDT
      @WeldingandNDT  2 года назад

      Thank you. Please join my channel to watch all videos. Joining Link: ruclips.net/channel/UCH7nXSievFlbRKzKzEySbkwjoin

  • @ilangkumarkumar377
    @ilangkumarkumar377 4 года назад +2

    Dear sir, Nice stuff. I knew the holding time is 10 minutes as per B 31.3, but 6 minutes per centimetre of thickness and 2hrs maximum. Could you please provide me reference?

  • @devkumar-gk2bo
    @devkumar-gk2bo 4 года назад

    Guruji .....great explanation...

  • @saurabhsurti1075
    @saurabhsurti1075 4 года назад +1

    Great lecture sir!!

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @saleeshmadhavan6077
    @saleeshmadhavan6077 2 года назад

    Sir, set pressure for PRV ? Chloride content of water used for SS ?

  • @rupakdey1478
    @rupakdey1478 3 года назад

    Sir, please discuss pump selection criteria during hydraulic test

  • @Allinone-jw3sy
    @Allinone-jw3sy 4 года назад

    Language is very good and very good info sir...

  • @unclejamesx9808
    @unclejamesx9808 2 года назад

    Very nice. Thank you sir

    • @WeldingandNDT
      @WeldingandNDT  2 года назад

      Thank you. Please join my channel to watch all the videos. Joining Link: ruclips.net/channel/UCH7nXSievFlbRKzKzEySbkwjoin

  • @user-qx1fk9cu7p
    @user-qx1fk9cu7p 2 года назад

    Thank you very much ,,if we make a pressure test for pipes with liquid out of water, what is allowable drop in pressure?

    • @WeldingandNDT
      @WeldingandNDT  Год назад

      Thank you. Please join my channel to support my initiative. Joining Link: ruclips.net/channel/UCH7nXSievFlbRKzKzEySbkwjoin

  • @himagiriparasingi8142
    @himagiriparasingi8142 4 года назад

    Thankyou sir. Very good explanation.

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @pradeepreddy8651
    @pradeepreddy8651 3 года назад

    Very nice explanation sir
    Tqvery much

    • @WeldingandNDT
      @WeldingandNDT  3 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @rohitpatil3780
    @rohitpatil3780 4 года назад

    Thanks sir for explaining about hydro tesr.similarlyvrequesting you to guide about air test or pneumatic test.

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @NiranjanMehta1
    @NiranjanMehta1 4 года назад

    Very good. Keep making more such video

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @vasanthakumar-nv9fq
    @vasanthakumar-nv9fq 2 года назад

    Sir super explanation thank u so much sir

    • @WeldingandNDT
      @WeldingandNDT  2 года назад

      Thank you. Please join my channel to support me. Joining Link: ruclips.net/channel/UCH7nXSievFlbRKzKzEySbkwjoin

  • @saurabhsurti1075
    @saurabhsurti1075 4 года назад +1

    Is there any particular quality water required when we are carried hydro test in stainless steel components??

    • @NIKHILJADHAV333
      @NIKHILJADHAV333 4 года назад +1

      Demineralised water

    • @qismatali4073
      @qismatali4073 2 года назад

      @@NIKHILJADHAV333 as per SAES-A-007 water for SS should below 50pPM chloride conc. And PH value greater than 5.5

  • @omprakashmiddi6164
    @omprakashmiddi6164 4 года назад

    How much pressure drop allowed in Piping?
    What is the calculation for Piping systems?
    How to select the pressure gauges?

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      no pressure drop, pressure gauge selection explained in this video itself

    • @omprakashmiddi6164
      @omprakashmiddi6164 4 года назад

      @@WeldingandNDTThanks for your prompt response.
      What about due to temp. & lengthy piping systems difference.
      I faced a problem like this.

    • @ranjanprakash91
      @ranjanprakash91 4 года назад

      ASME SEC. VIII DIV.1 -UG -102 & 99 FOR MORE INFO.

  • @victors8456
    @victors8456 4 года назад +1

    Sir During hydro how much pressure difference allowed in two pressure gauges?

    • @qismatali4073
      @qismatali4073 2 года назад

      I guess 5% different is allowed if different heights

  • @vivekjindal1499
    @vivekjindal1499 4 года назад

    Sir, calculation of Hydro pressure is same EN standard or different calculation?? kindly explain on this

  • @narasimhabhagavatula8360
    @narasimhabhagavatula8360 3 года назад

    The main problem is isolation fittings calclations for safe testing

  • @erikzeynl4347
    @erikzeynl4347 3 года назад

    Thank you detailed explanation.

    • @WeldingandNDT
      @WeldingandNDT  3 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @rahulahir7775
    @rahulahir7775 3 года назад

    Really really helpful

  • @mohammedamjad3978
    @mohammedamjad3978 3 года назад

    Really excellent presentation.Thank you boss.

    • @WeldingandNDT
      @WeldingandNDT  3 года назад

      Thank you. Please join my channel to watch the members-only exclusive videos. Here is the link: ruclips.net/channel/UCH7nXSievFlbRKzKzEySbkwjoin

  • @arunr3695
    @arunr3695 4 года назад +1

    Sir, If we have a system with 90m height. Due to the height variations in pressure gauge reading arises. And how much difference between both gauges is allowed?
    And in section where it is mentioned?
    Thanks

  • @muhammadbilawal8075
    @muhammadbilawal8075 4 года назад

    Does hydro test comes under metallurgy / material science technology?

  • @lokeshmanjhi
    @lokeshmanjhi 3 года назад

    Sir, please explain about Overlay welding in your style..

  • @kafeelahmad9803
    @kafeelahmad9803 4 года назад

    from where you are taking the value 118 and 138

  • @qismatali4073
    @qismatali4073 2 года назад

    Sir, thank you for your efforts. Could you please guide how to prepare safety instruction sheet for process piping?

    • @WeldingandNDT
      @WeldingandNDT  2 года назад

      Sure. Thank you. Please join my channel to watch all the videos. Joining Link: ruclips.net/channel/UCH7nXSievFlbRKzKzEySbkwjoin

  • @saanbk7258
    @saanbk7258 2 года назад

    Sir how you get St 138 n Sd 133 please reply

  • @qismatali4073
    @qismatali4073 2 года назад

    Sir, how to calculate pressure for process piping.

  • @jiyaslittleworld9598
    @jiyaslittleworld9598 4 года назад

    Nice video sir ji

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @krkumaran3718
    @krkumaran3718 3 года назад

    good explanation

    • @WeldingandNDT
      @WeldingandNDT  2 года назад

      Thank you. Please join my channel to watch all the videos. Joining Link: ruclips.net/channel/UCH7nXSievFlbRKzKzEySbkwjoin

  • @viswanath31
    @viswanath31 3 года назад

    When to include bolting

  • @sksaddamhussainofficials6971
    @sksaddamhussainofficials6971 3 года назад

    How to know pipe is fully full

  • @chhatrapatishivaji7212
    @chhatrapatishivaji7212 3 года назад

    Very useful video sir..

    • @WeldingandNDT
      @WeldingandNDT  3 года назад +1

      Thank you. Please visit my website www.weldingandndt.com/

  • @vikeshpatel8801
    @vikeshpatel8801 3 года назад

    Sir,If pressure increased?

  • @tushantpulkanthwar1200
    @tushantpulkanthwar1200 4 года назад

    Great video.... Thanks....

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @parisworld5343
    @parisworld5343 3 года назад

    add Valve helium leka test by hood method as per asme sec.v

  • @saddamhussain-br9gz
    @saddamhussain-br9gz 4 года назад

    as per b31.3 which formula is to be use

  • @arvindchauhan54
    @arvindchauhan54 Год назад

    Sir loop file kaise bnate h oske upe videos daliye n🙏

  • @venkateshgondu2645
    @venkateshgondu2645 3 года назад

    How to get pdf files of this topics

  • @mohan12357
    @mohan12357 4 года назад

    Well explained sir

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @er.kiran.mt15
    @er.kiran.mt15 3 года назад

    Sir how to see St & Sd?

  • @yme9980
    @yme9980 4 года назад

    How much pressure drop is allowed during pressure test after reaching test pressure?

  • @santoshrana1785
    @santoshrana1785 3 года назад

    Sir Hydrotest me guaje ka selection kaise karege pls guide me....

  • @khurshedansari9598
    @khurshedansari9598 4 года назад

    Pressure drop kitne limit tk acceptable hota hai aur kis condition mei aur calculation kase krte hain ki kitna water hai pipe mei

    • @WeldingandNDT
      @WeldingandNDT  4 года назад +1

      no pressure drop

    • @khurshedansari9598
      @khurshedansari9598 4 года назад

      Sir calculation kase krte hain ki pipe mei kitna water hai

    • @souravbohrays4189
      @souravbohrays4189 4 года назад +1

      no pressure drop allowed but in piping if pressure exceed than the max pressure than can release upto hydrostatic test pressure than again hold

    • @ranjanprakash91
      @ranjanprakash91 4 года назад +2

      Theoretical volume of pipe Vt= (ID)^2/4*π*Length of pipe in (m)
      Where, I -internal dia of pipe
      π-3.14

    • @khurshedansari9598
      @khurshedansari9598 4 года назад

      @@ranjanprakash91 Dear fd please details in brief plz..

  • @rajasekharbarla6179
    @rajasekharbarla6179 3 года назад

    Sir ji please do pratictical vedio on hydro test

  • @JavedAlam-gy6vt
    @JavedAlam-gy6vt 4 года назад

    Sir Please Explain how to calculate welding consumable...

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Already explained in one of my video. Please check into the playlist.
      Thank you. Please visit my website www.weldingandndt.com/

  • @sksaddamhussainofficials6971
    @sksaddamhussainofficials6971 3 года назад

    How to calculate water volume in sylender

  • @nikhildaunderiya3944
    @nikhildaunderiya3944 4 года назад

    Pls upload single video related painting and blasting.

  • @akashvimal9222
    @akashvimal9222 3 года назад

    Good sir

    • @WeldingandNDT
      @WeldingandNDT  3 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @vinodbhosale2103
    @vinodbhosale2103 4 года назад

    Sir you are superb

  • @nirmalsurendranmenon7049
    @nirmalsurendranmenon7049 4 года назад

    Sir why are you taking ASME Sec VIII Div 1 and not B31.3?

  • @legendsyamokkaElephant
    @legendsyamokkaElephant Год назад

    Thnks sir🙏🙏🙏

    • @WeldingandNDT
      @WeldingandNDT  Год назад

      Acceptance Criteria video also available on my channel. Please check into the playlist. Thank you. Please join my channel to support my initiative. Joining Link: ruclips.net/channel/UCH7nXSievFlbRKzKzEySbkwjoin

  • @nreependrakumar395
    @nreependrakumar395 3 года назад

    Sir pls help me with another video how to Known st and sd value in MPA from different different sections.pls clarify about It sir 🙏

    • @WeldingandNDT
      @WeldingandNDT  3 года назад

      Thank you. Please join my channel to watch all the videos. Joining link: ruclips.net/channel/UCH7nXSievFlbRKzKzEySbkwjoin

  • @AshuSingh-zt5xb
    @AshuSingh-zt5xb 4 года назад

    Sir where I will get ASME book

  • @deepeshraghwani3443
    @deepeshraghwani3443 4 года назад

    Sir plz continue RT session.. we r waiting from long period..

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you, but so far the numbers are not encouraging so I have dropped the plan. I may plan in future, if the watch time will improved.
      Please visit my website www.weldingandndt.com/

    • @deepeshraghwani3443
      @deepeshraghwani3443 4 года назад

      @@WeldingandNDT k. We got it.. we were started a whatsapp group at international level for welding and ndt purpose. If u want to join plz msg me personally

    • @mohammadshahalamhussain.ss3767
      @mohammadshahalamhussain.ss3767 2 года назад

      @@deepeshraghwani3443 brother any telegram channels?

  • @saddamhussain-br9gz
    @saddamhussain-br9gz 4 года назад

    When will come part 2 video sir

  • @chakradharpradhan357
    @chakradharpradhan357 4 года назад

    Sir different stainless electrode ki video banaea with sample

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @engineersoutlook7
    @engineersoutlook7 4 года назад

    Nice

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website for notes, videos and other important informations www.weldingandndt.com/

  • @kausarraza8448
    @kausarraza8448 4 года назад

    Sir where could I get the ST/SD
    Data
    Please explain

  • @khurshedansari9598
    @khurshedansari9598 4 года назад

    Sir please Gas pipe line ka hydro test aur calculation aur water removing ka full details video bnaiye plz

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website www.weldingandndt.com/

  • @pradeeps9152
    @pradeeps9152 4 года назад

    How to find Test water temp

    • @arunr3695
      @arunr3695 4 года назад

      We can check temperature using thermometer at the pump area or at vent line

  • @rc7147
    @rc7147 4 года назад

    Sir first comment 😎

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Super

    • @sahebhussain8503
      @sahebhussain8503 4 года назад

      @@WeldingandNDT sir can you explain according to API 1104.because in pipeline hydrotst is very important ..it's request kindly go through pipeline

  • @souravbohrays4189
    @souravbohrays4189 4 года назад

    non flamable,non toxic liquid,weld joint should be free of any kind of masking,temprature of metal,temprature should be monitor ,pressure guage should pe as per spec,only 1 required which should be clearly visible and readible to inspector,pressure guage should be callibrated with master guage should be callibrated from nabl approved lab,manifold should be callibrated,vent should be at top and drain at bottom, air pessage should be check during draining,guage should be placed at top most position of equipment,all welding ,fitup,heat treatment ,ndt should be done before hydro test,for vertical pressure additional static head pressure should be add ,hydro area should be isolated,hydrostatic test to check aginst stress due to internal pressure for external pressure vaccum testing to be done,for ss chloride content is must

    • @souravbohrays4189
      @souravbohrays4189 4 года назад +1

      now this video is complete.

    • @abdullaar3590
      @abdullaar3590 4 года назад

      Sir can I get your WhatsApp number

    • @WeldingandNDT
      @WeldingandNDT  4 года назад

      Thank you. Please visit my website www.weldingandndt.com/

    • @ketankanojiya9891
      @ketankanojiya9891 2 года назад

      @@souravbohrays4189 can you share your contact details pls

  • @TheAlamshamshad
    @TheAlamshamshad 3 года назад

    Bro can you send me pdf of LSR

  • @abdullaar3590
    @abdullaar3590 4 года назад

    Sir where can I get ASME book

    • @WeldingandNDT
      @WeldingandNDT  4 года назад +1

      It's not free. But you can download pirated version from telegram.
      Thank you. Please visit my website www.weldingandndt.com/