VCB TRIP ALARM (VACUUM CIRCUIT BREAKER) | ETO TROUBLESHOOTING

Поделиться
HTML-код
  • Опубликовано: 21 окт 2024

Комментарии • 85

  • @manhucnguyen799
    @manhucnguyen799 Год назад +2

    I am starting a maintenance job and my work is related to this breaker repair category. It's great that you shared this with us, thank you very much for that. Wishing you and your family all the best

  • @charliegricalda3176
    @charliegricalda3176 2 года назад +1

    I'm a former Radio Operator and now I'm a OIC-NW license officer. I think some trouble shooting guide indicated on the block diagram. It's mean the trouble shooting will definitely in a particular place since the ship is almost new, so the solenoid (function is to amplified the required current in order to run the motor to open up.) Since the c/e and 1st/engr act a electrian onboard. But I think if the ship become old I think it's better to have an electrician who's knowledge in electronics techinical and we'll verse in such like computer, electronics, electrical and even knowledge in mechanical as well. Take care, God bless! Salute you sir. Peace

  • @kevinbalilu8790
    @kevinbalilu8790 7 месяцев назад

    good day ka lecky! thank you for sharing your idea in troubleshooting in VCB. laking tulong po to sa amin ka leckky....

  • @draw584
    @draw584 3 года назад +3

    Sir gud day... hndi ba sya delikado na mag testing nang VCB na nasa switchboard? Hndi ba pag mag Switch ON magsupply sya sa generator? Slamat..safe sailing....

  • @alanalanis1676
    @alanalanis1676 3 года назад +8

    Thanks for sharing your knowledge, your videos are precious for us the unexperienced ETOs , what other causes can trip a reverse power alarm?

    • @leckyjake
      @leckyjake  3 года назад

      Thank you.

    • @aamirawan7998
      @aamirawan7998 3 года назад +2

      The most probable and obvious cause is the failure of prime mover. But as shown in this video it was a false alarm due to VCB failure.

  • @InTransitGaming
    @InTransitGaming 3 года назад +1

    Hey jake, We had a similar situation onboard my vessel - during port state inspection the EMDG did not connect to the board(engineers swear they checked it before hand

    • @leckyjake
      @leckyjake  3 года назад +1

      Thank you for the support

  • @bithiludayakumar7300
    @bithiludayakumar7300 3 года назад +1

    Excellent video great work sir ! waiting for more vidoes

  • @hasibhasan8308
    @hasibhasan8308 2 года назад

    Can you please upload complete VCB rack out . Appreciate for all of your videos

  • @nafeesmd7
    @nafeesmd7 3 года назад +2

    Great video. Great explanations.

  • @Sdfghjiy
    @Sdfghjiy 3 года назад +1

    Jake you are doing great job, Pls keep it up.

  • @imamcahyoseptiawan
    @imamcahyoseptiawan Год назад

    Experience is the best teacher

  • @yusufmahmud5409
    @yusufmahmud5409 2 года назад

    Good Jobs lecky,, you share everything you know

  • @NaeemKhan-vq3gg
    @NaeemKhan-vq3gg 2 года назад

    More respect from 🇸🇦 🙏 👏 🙌 💯

  • @conedelacruz7779
    @conedelacruz7779 3 года назад +2

    I think there is a dedicated spring release mechanism in this kind of breaker. Also if you just close the breaker I think you just release the closing spring but the opening spring is still charged. Please correct me if I'm wrong Sir.. By the way I enjoy watching your videos they are very informative.

    • @leckyjake
      @leckyjake  3 года назад +1

      Nope it is the same spring for closing and opening. So if you close the breaker without the Motor connection or the Jack Cable then it will stay released unless you charge it

    • @inothome
      @inothome 3 года назад +3

      @@leckyjake Cone Dela Cruz, you are absolutely correct!! The closing spring / closing action charges the trip spring. That is why he was able to trip the breaker when the semaphore was showing the spring was discharged. The spring charged semaphore is just for the closing spring. To properly discharge all stored energy, on most spring close breakers, you need to disconnect spring charging motor, do a close operation to discharge closing spring, then do an open operation to discharge trip spring that was charged when the breaker was closed. Some breakers can even do two close operations on one spring charge cycle. So always close, open and try close again before sticking your fingers in the breaker mechanism.

  • @AminulIslam-hq7ot
    @AminulIslam-hq7ot 2 года назад

    Thank you so much for Sharing your knowledge

  • @josephpaulabapo4796
    @josephpaulabapo4796 2 года назад

    Thank you for sharing your knowledge and actual experience onboard. Godbless & more videos troubleshooting…

  • @lorrylumberto2023
    @lorrylumberto2023 3 года назад

    Very nice thank for sharing knowledge

  • @electronic3221
    @electronic3221 2 года назад

    May you please clarify a moment?
    If i press close on circuit breaker before rack out then it means that we take generator on bus bars. But generator not started. As a result redundant load on bus bar. Generator will act as an engine.

  • @cyrildelacruzjr6831
    @cyrildelacruzjr6831 3 года назад

    Keep SAFE 🙏 maraming salamat SA turo ninyo God bless 🙏

  • @mostafafalah4361
    @mostafafalah4361 Год назад

    How do you think that the issue with the VCB it is reversed power , so why you didnt think there is something wrong with the generator?

  • @muhamadrizaldi9635
    @muhamadrizaldi9635 2 года назад

    I like you video so usefully , if u have time please show me How to do the operated well of OWS (OIL WATER separator) on board and part of Name with funcion please..

  • @pelautina2029
    @pelautina2029 2 года назад

    Lecky thanks for this video, im Eto also but still learn

  • @fatihdanfatimah1838
    @fatihdanfatimah1838 3 года назад

    Thank you Sir, for explanation and never stop to share to us

  • @harindersingh1133
    @harindersingh1133 3 года назад

    your vedio is so informative thanks for sharing your knowledge 😊

  • @Tulfonatic-sarcasticsm
    @Tulfonatic-sarcasticsm 3 года назад

    astig sir... Thanks for sharing your knowledge... keep safe always

  • @blazvrhunec9920
    @blazvrhunec9920 3 года назад

    Hi,
    I'm surprised, that ships VCB's doesn't have Relay switch circuit, to check the coils.
    I work in a hydro power plant and all our main switces have these sort of control.

  • @michaelsilleza1635
    @michaelsilleza1635 3 года назад

    Sir jake thank u more power gob bless i love eletrical...

  • @engdominicnyaboga8684
    @engdominicnyaboga8684 Год назад

    I learned a lot from this video

  • @inothome
    @inothome 3 года назад

    And if it was mechanically sticking, it would have tripped when you had the control power removed from it. So what am I missing here? Is there a trip circuit monitor that was tripping it due to low resistance? Which normally only sends indication of an electrically open trip circuit. But I see an 85X device, which I am not familiar with. Thanks

    • @inothome
      @inothome 3 года назад

      Where did my first comment go? I was genuinely curious.

  • @25denzil
    @25denzil 3 года назад

    Great video. Lots to learn in this

  • @matega6485
    @matega6485 Год назад

    Hi..thank u for sharing...

  • @நிவிராஜ்மோகன்

    Refrigerator container does not cutoff set temperature please give some ideas
    Set temperature display side blinks al52 code

    • @leckyjake
      @leckyjake  2 года назад

      how much is the return and supply? as well as the pressures

  • @janehidalgo3724
    @janehidalgo3724 3 года назад

    Thanks for another knowledge, Sana wag kng magsawa na mag share ng mga idea leckyjake...

  • @brentmartinez7663
    @brentmartinez7663 3 года назад +1

    Thank you for sharing this Boss Jake!!! Godbless

  • @jeremiahlira1962
    @jeremiahlira1962 3 года назад

    Thank you sir for this very useful video

  • @ananda755200200
    @ananda755200200 Год назад

    Can you do a video of boiler and boiler alarm???

  • @eristikasihombing4715
    @eristikasihombing4715 Год назад +1

    hallo sir,how many persons electrician on your ship?

  • @bertapartv
    @bertapartv Год назад

    Very nice master

  • @adventgg7403
    @adventgg7403 3 года назад +1

    thank you for the knowledge sharing.. stay safe po god bless..

  • @donaldpatan930
    @donaldpatan930 3 года назад

    Salamat sa pag share lect God bless

  • @edwindaling782
    @edwindaling782 Год назад

    Galing mo nmn idol

  • @keything8487
    @keything8487 2 года назад

    we usually just send ours out, and install a spare...so we get 'warranty"

  • @ederandrade4302
    @ederandrade4302 3 года назад

    Very informative video, thanks for the share!!!

  • @kuyapetstv1233
    @kuyapetstv1233 3 года назад

    thanks for sharing sir God bless

  • @monzurhasan3583
    @monzurhasan3583 3 года назад +2

    Love you bro 🙏🙏

  • @HwaKanJung
    @HwaKanJung 3 месяца назад

    I love this video

  • @benzblogsVlogs
    @benzblogsVlogs 3 года назад

    Good job sir take care

  • @roldanocares8262
    @roldanocares8262 3 года назад

    Thank you Master

  • @junepar13
    @junepar13 2 года назад

    Thank you very helpful

  • @normansale1542
    @normansale1542 3 года назад

    Very informative sir jake.

  • @TanveerShah-z8v
    @TanveerShah-z8v Месяц назад

    Thanks boos

  • @edu4540
    @edu4540 2 года назад

    Thank you sir

  • @manojmadane700
    @manojmadane700 3 года назад

    God bless u sir🙏🙏

  • @manojmadane700
    @manojmadane700 3 года назад

    Thank u so much boss....

  • @edmaraninapon3987
    @edmaraninapon3987 3 года назад

    Sir pwide lokal laguage lng tayo ( TAGALOG)?

  • @jeromewelch7409
    @jeromewelch7409 3 года назад

    That was awesome

  • @syedkhajamohiuddin4121
    @syedkhajamohiuddin4121 2 года назад

    In this video u had not shown the trouble shoot very clearly

  • @brintstripgaming1991
    @brintstripgaming1991 Год назад

    ❤❤

  • @reymundbotalon4884
    @reymundbotalon4884 3 года назад +1

    Thanks sir leckyjake

    • @leckyjake
      @leckyjake  3 года назад

      Thank you for your support

  • @nazmulhassan7995
    @nazmulhassan7995 3 года назад

    How can you work MSB without blackout?

    • @toron8418
      @toron8418 3 года назад +1

      You isolate one generator usually you have 2 per side in case of one failure the other generator supply that line...

    • @bt9604
      @bt9604 Год назад

      Bus tie breaker

  • @harishsingh9961
    @harishsingh9961 3 года назад

    sirgood video

  • @reohsamjale6116
    @reohsamjale6116 3 года назад

    Slmt sir leckyjake😁

  • @ksantostitanos
    @ksantostitanos 3 года назад

    Cool.

  • @jeffreyheven1721
    @jeffreyheven1721 3 года назад +2

    Puru englesh wala bang chenis

  • @vijayshinde6320
    @vijayshinde6320 Год назад

    O no 😂

  • @SophyHarlan-l6s
    @SophyHarlan-l6s 27 дней назад

    Martin Mark Gonzalez William Anderson Elizabeth

  • @lucasojeda90
    @lucasojeda90 3 года назад

    for more videos

  • @liwinthomas4107
    @liwinthomas4107 3 года назад

    🙂

  • @zaitonyahya4768
    @zaitonyahya4768 Год назад

    Terjemah&doa