If we have four floors building and each having separate electricity connection with a common rooftop. Whether it is possible to have separate 2KW solar system for each having common earthing and common supporting structure connected with individual uses and supply. How much will be rating of each Inverter and other total space required on terrace for all 4 x2kw system. Where we can save?
Sir I Agree that both the inverters are premium and have very good performance. But in the residential sector, for size of 10 KW, both the inverters are not viable as the customer is not ready to spend these extra bucks. Can you please give insights of the benefits of using delta in place of Polycab/Growatt so that it can help in taking informed decisions.
Bhaiya ji Mery pass normal c20 150ah ki battery hi or ak 12v 150ah solar battery series mein mila kar solar me use kr sakti h kya Mery pass 24v 1100va ka solar inverter hi
Suppose there is a fault comes in one of the single 125kw inverter , then it means 125kw will not genrate that day , but if fault will be in 60kw then loss of genration for that day will be just the half
Despite all advantages of AC modules over String inverters, do we have any option to create a hybrid solar system using these AC modules ( Regular module+ Enphase Microinverter) to take care of our energy needs in case of power outages ? Is it that connecting the string from AC module to genset Port on another separate hybrid string inverter with a battery and grid connected to it, the only solution for this? This would be a costly affair as one has to purchase microinverter to take advantage of no dc arc, no dcdb requirements, no dc earthing etc but then to incur additional cost for hybrid string inverter with genset port. Request you to please make a dedicated video with a solution for this as absolutely no information available anywhere about this. Thanks 🙏
Thank you so much so sir You are talking about built in energy data logger, so, can we take data since it is installed. If yes, please tell us about that Thank you Thank you Thank you
Sir I connected 3 panels of 335 watt each with gamma plus(recently purchased). I checked all panels voltage and current and try a lot to get max output. But even after giving 80% load the "spv" ampere is only 16-17 ampere and the battery is discharging. Also the battery charging amp is zero. I have seen maximum ampere only while the battery is charging(19-20 batt charging amp). Please guide what may be the problem and how to solve it. Is the inverter is faulty?Looking forward to your reply 🙏
Would you recommend Zeversolar now that it has been acquired by a Chinese Consortium . Among Chinese brands which brand would you recommend for 10KW in India?
Sir i m very thankful 2 u bcos u explained root things in very easy language... Sir plz all explain pros and cons of AC solar module. Bcos baki solar inverter ki guarantee 5 yr ki hai but loom ac solar module ki 25 yrs ki. Aur dusre inverter ki efficiency time to time decrease hoti jati hai like after 5 yr efficiency kam ho jati hai but loom ac solar ki 25 yr tk same efficiency rahti hai. Kya sahi hai aur kya galt plz guide me sir. I hav to install 5kw ongrid system 4 domestic purpose. Plz apke right guide se mujhe genuine aur right system lagwa sakta hu nahi to mera money waste ho skta hai... Plz sir clear this confusion aur ye confusion bahut se logo ki hai jo ac solar module aur dusre solar system ko lagana chahte hai... Plz guide sir.. bcos aap hi isko achhi tarah se smjha sakte hai..... Plz video bana kr guide kijiye sir....
Sir delta ka kahi service thik nahi h isne to apna palla jhad liya bole spd ki wajah se jala h to under warranty khatam kardi aur 34000 mange advance me.
Sir agar apka tv under warranty h aur kharab ho jaye aur jab company walo ko bole thik karke do aur company wale bole ye to stabilizer ki wajah se jala h to warranty kis baat ki. Mudda ye h ki apna palla kyo dusre pe jhad rahe ho. Jab aapne warranty di h , kharab hoga to thik karne ke liye hi warranty di hogi n ki pumplet pe chapne ke liye dediya.
@@sanjivgour8786 SPD fails during over voltage condition , overvoltage in DC side can only come due to cable fault , cable fault will only come due to , poor cable management by installation team ,Now tell me who will be responsible for SPD Faliour
@@SustainableEveryDay I changed spd ac but when I on the Inverter mcb tripped . What is the fault then and no one comes there to detect the fault. In spd no earthing cable connect.
I am very confused and shucked in a huge problem of inverter sizing and solar panel sizing. Kindly answer to my Question. Question: We have 1 HP AC 3phase Motor and we want to calculate how much solar power and inverter size we required? 1 HP=746 Watt Current it draws during running condition 3.39 Ampere Starting current 1hp of motor requires 3.39*6=20.34 Ampere If we design Solar System at 746 watt with 3.39 Ampere then with safety factor of 1.35 we need almost 1100 watt of panels and these panel cannot provide 20.34 Starting current to Motor . Inverter may switched off flickered.... now to start Motor we need 20.34 Amperes . what to do in this case should we design and calculate our system on starting current ? Starting Power= 220*20.34=4474 watts Solar Panel we required =4474*1.35= 6040watts It is blowing my mind that to provide starting power to a motor we need to install 6500 watts of Solar system for just 746 watt of motor. If this is not So, Kindly tell me how motors achieve starting current of 20.34 Ampere with 1100 watt of solar panels. Kindly Answer this i know every thing about solar designing just this point is confusing me alot and I am shucked at all. And tell me which power starting or running power we will consider in designing phase of inverter and solar panel calculation? It is also blowing my mind that people are running smoothly 746 watt of motor on 1100 watt of solar panel without any problem but how ? The logic behind it is confusing me because AC, Refrigerator ..heavy loads required high amount of current
Sir there is very little information available for hybrid solar system and hybrid solar inverters. There is absolutely no information on DG +PV System available for us. Request you to please make a dedicated video on hybrid system and hybrid inverter options available in India. Please also make a detailed video on Panel level monitoring options available in India for small scale commercial customers and residential segment
With due respect Sir please compare the delta inverter with SMA present series Inverter. And if I compare the Delta inverter with SMA present series inverter it give more features and Benefits. Also please educate our community with SMA shade fix and opticool techniques Also please explain about today’s fastest communication technology which is Modbus TCP/Ip provided by SMA
Hi Niket bhai , this information is collected from SMA Technical date sheet , model no. Is mentioned you can download and cross check , I have just done a comparison between 2 make for domestic users below 10kw who has a limited budget yar , for large scale user SMA tripower series is the best , as my company personally use it over other Inverters , I hope I have not offended your feelings in any way , thanks for highlighting your concern , also why does SMA Inverter comes with a Inverter manager for communication?
@@SustainableEveryDay Sir sma new inverter comes with 50 % overloading. Only STP 60 and SHP 75 comes with Inverter manager as it is designed for commercial and utility plants. Also, to provide higher power to weight ratio, the control unit provided externally. Which called Inverter manager.
Sir i am installing 150kw on grid solar and my service provider is asking that which inverter i want so plz suggest me between these 2 inverters delta or growatt.
Bhai solar power generation ka kaam is highly secure Advance Electrical Design & Engineering Institute ,Institute for Electrical Design Training Course , Institute for Design in Substation Design Training, Designing Course for Solar Structure Design , Online Design Training Courses for Electrical System Design, Solar power Plant And Substation Design C-1, 2nd Floor, Near Nirman Vihar Metro Station, Laxmi Nagar, New Delhi, Delhi 110092 084670 24957 maps.app.goo.gl/vbkgDkm7sweTfVJw9
Hello sir meri firm ki sales b m khud dekhta hu ...meri poori working yahan online chalti h google promotion s..indiamart and just dial s promotions chalta h...m sales b job karta hu..sir plzzz meri saari baaton ko sunkar plzzz help me sir.....
Technical ya sales jisme b achha paisa mile m kr skta hu sir and agar aap chaahe toh aap mjhe work dde dena m product bech kr b dikha dunga dusre product k comparison m kr k customer ko apna product bech sakta hu sirr plzzz give me reply
Sir where does Voltronic Power stands as compared to these benchmark inverters? In Pakistan majorly voltronic Power inverters are used for hybrid systems.
Hi Asfak bhai , this information is collected from SMA Technical date sheet , model no. Is mentioned you can download and cross check , I have just done a comparison between 2 make for domestic users , for large scale user SMA tripower is the best , as my company personally use it over other Inverters , I hope I have not offended your feelings in any way , thanks for highlighting your concern
@@SustainableEveryDay Hi sir i have a question I work in indian railways We have Auxillary transformer at stations and LC gates to step down 25kv to 220v AC supply We have 4 types of Auxiliary transformer 5kva,10kva,25kva and 100kva as per load at different stations Sir in the transformer the output voltage is 220v but we get 247v or more at the sockets also the voltage between neutral and earth is 5-10 volts or more and it's never stable . Sir why this occurs and what can be the probable solutions please reply
Very great knowledgeable person you are himanshu bhai .
Thanks for the support Pranjal
Can we use three phase iverter for home appliance??
I am planning install Hitachi how is it ? Should I switch instead to Delta?
Very useful information Sir Thank you
I shared your video in our Solar Group 👍👍👍
Bhai thanks for the support
what is the use of MPPT Tracker in Solar inverter selection and how to decide no of strings required to select correct sizing of inverter??
What about Goodwe?
It's a good Inverter in budget
Very Good Comparison 👌
Thanks for the support
If we have four floors building and each having separate electricity connection with a common rooftop. Whether it is possible to have separate 2KW solar system for each having common earthing and common supporting structure connected with individual uses and supply. How much will be rating of each Inverter and other total space required on terrace for all 4 x2kw system. Where we can save?
Super explanation
Sir I Agree that both the inverters are premium and have very good performance.
But in the residential sector, for size of 10 KW, both the inverters are not viable as the customer is not ready to spend these extra bucks.
Can you please give insights of the benefits of using delta in place of Polycab/Growatt so that it can help in taking informed decisions.
Service support is very good , in delhi , mumbai , banglore they offer one day replacement.
Delta inverter main ac low volt kyu aa raha hain
Explain power one and Sun Grow, Growatt inverter also
sure soon
Bhaiya ji Mery pass normal c20 150ah ki battery hi or ak 12v 150ah solar battery series mein mila kar solar me use kr sakti h kya Mery pass 24v 1100va ka solar inverter hi
Bilkul use Kar sakte hai
@@SustainableEveryDay
Battery me overhiting ki problem ..
Sir 1mw ke solar plant meh kitne kilowatt ke inverters lgwayie
Use , 15 no. Of Inverter each of 60kw aur sab Inverter to 10% extra dc overload
@@SustainableEveryDay thank sir and for 2 MW
@@SustainableEveryDay Why not to go for 8 125Kw inverters ? Is there any extra merit of using 60kw ones?
Suppose there is a fault comes in one of the single 125kw inverter , then it means 125kw will not genrate that day , but if fault will be in 60kw then loss of genration for that day will be just the half
60kw 32no
Eapro 3200 mppt 24 volt kaisa hai
Sir i have some problems face in generation
Nice video sir
Thanks for the support
Despite all advantages of AC modules over String inverters, do we have any option to create a hybrid solar system using these AC modules ( Regular module+ Enphase Microinverter) to take care of our energy needs in case of power outages ? Is it that connecting the string from AC module to genset Port on another separate hybrid string inverter with a battery and grid connected to it, the only solution for this? This would be a costly affair as one has to purchase microinverter to take advantage of no dc arc, no dcdb requirements, no dc earthing etc but then to incur additional cost for hybrid string inverter with genset port. Request you to please make a dedicated video with a solution for this as absolutely no information available anywhere about this. Thanks 🙏
Sure let me plan for it
thanks sir
Thanks for the support
Thanks sir
Thank you so much so sir
You are talking about built in energy data logger, so, can we take data since it is installed.
If yes, please tell us about that
Thank you
Thank you
Thank you
Which is good for 5KW single phase. Delta, Sofar, Solis or Growatt
Growatt & Delta both are good
Sir I connected 3 panels of 335 watt each with gamma plus(recently purchased). I checked all panels voltage and current and try a lot to get max output. But even after giving 80% load the "spv" ampere is only 16-17 ampere and the battery is discharging. Also the battery charging amp is zero. I have seen maximum ampere only while the battery is charging(19-20 batt charging amp). Please guide what may be the problem and how to solve it. Is the inverter is faulty?Looking forward to your reply 🙏
Helpful
Sir nexus solar 5 kg watt solar inverter Indian made is good or bad
Actually I have never used it
How is Fronius for residential purpose.6KW Quality ? Service etc inindia ?
Budget Inverter but service is slow
@@SustainableEveryDay Fronius is one of the costliest inverters and easily the top ranking ones alongwith SMA. It is not a budget inverter.
Bro best solar inverter in India??
Would you recommend Zeversolar now that it has been acquired by a Chinese Consortium . Among Chinese brands which brand would you recommend for 10KW in India?
Sir SOLIS kesa he
It's ok for domestic purpose
Goodwe single phase inverter kaisa hai sir?
Delta से अच्छा है या बराबर?
Delta is better
How is saj inverter
I have never used it
Sir i m very thankful 2 u bcos u explained root things in very easy language... Sir plz all explain pros and cons of AC solar module. Bcos baki solar inverter ki guarantee 5 yr ki hai but loom ac solar module ki 25 yrs ki. Aur dusre inverter ki efficiency time to time decrease hoti jati hai like after 5 yr efficiency kam ho jati hai but loom ac solar ki 25 yr tk same efficiency rahti hai. Kya sahi hai aur kya galt plz guide me sir. I hav to install 5kw ongrid system 4 domestic purpose. Plz apke right guide se mujhe genuine aur right system lagwa sakta hu nahi to mera money waste ho skta hai... Plz sir clear this confusion aur ye confusion bahut se logo ki hai jo ac solar module aur dusre solar system ko lagana chahte hai... Plz guide sir.. bcos aap hi isko achhi tarah se smjha sakte hai..... Plz video bana kr guide kijiye sir....
Sir delta ka kahi service thik nahi h isne to apna palla jhad liya bole spd ki wajah se jala h to under warranty khatam kardi aur 34000 mange advance me.
Bhai SPD is a consumable part , for every company , SPD Faliour is due to external fluctuations , not a fault of inverter manufacturer
Sir agar apka tv under warranty h aur kharab ho jaye aur jab company walo ko bole thik karke do aur company wale bole ye to stabilizer ki wajah se jala h to warranty kis baat ki. Mudda ye h ki apna palla kyo dusre pe jhad rahe ho. Jab aapne warranty di h , kharab hoga to thik karne ke liye hi warranty di hogi n ki pumplet pe chapne ke liye dediya.
@@sanjivgour8786 SPD fails during over voltage condition , overvoltage in DC side can only come due to cable fault , cable fault will only come due to , poor cable management by installation team ,Now tell me who will be responsible for SPD Faliour
@@SustainableEveryDay I changed spd ac but when I on the Inverter mcb tripped . What is the fault then and no one comes there to detect the fault. In spd no earthing cable connect.
Sir what should I connect with ongrid solar inverter output for High voltage coming from govt supply other than spd.
Sir off grid me konsa inverter best hai 5 kw
Sukam
Waree ka inverter kaisa hai
It's good
Hi Could YOU please suggest which is a better and cost effective Inverter between DELTA/POLYCAB/K SOLAR FOR A 10KW ROOFTOP PLANT ?
Delta
Sir, what is maximum amd normal efficiency of solar inverter?
for which make & model ? because its different for different company
@@SustainableEveryDay ,kehua company and rating has 3.125 MW ac.
I am very confused and shucked in a huge problem of inverter sizing and solar panel sizing.
Kindly answer to my Question.
Question: We have 1 HP AC 3phase Motor and we want to calculate how much solar power and inverter size we required?
1 HP=746 Watt
Current it draws during running condition 3.39 Ampere
Starting current 1hp of motor requires 3.39*6=20.34 Ampere
If we design Solar System at 746 watt with 3.39 Ampere then with safety factor of 1.35 we need almost 1100 watt of panels
and these panel cannot provide 20.34 Starting current to Motor . Inverter may switched off flickered....
now to start Motor we need 20.34 Amperes . what to do in this case should we design and calculate our system on starting current ?
Starting Power= 220*20.34=4474 watts
Solar Panel we required =4474*1.35= 6040watts
It is blowing my mind that to provide starting power to a motor we need to install 6500 watts of Solar system for just 746 watt of motor.
If this is not So, Kindly tell me how motors achieve starting current of 20.34 Ampere with 1100 watt of solar panels.
Kindly Answer this i know every thing about solar designing just this point is confusing me alot and I am shucked at all.
And tell me which power starting or running power we will consider in designing phase of inverter and solar panel calculation?
It is also blowing my mind that people are running smoothly 746 watt of motor on 1100 watt of solar panel without any problem but how ? The logic behind it is confusing me because AC, Refrigerator ..heavy loads required high amount of current
Bhaya can you explain Oversizing of inverter
Sir there is very little information available for hybrid solar system and hybrid solar inverters. There is absolutely no information on DG +PV System available for us. Request you to please make a dedicated video on hybrid system and hybrid inverter options available in India. Please also make a detailed video on Panel level monitoring options available in India for small scale commercial customers and residential segment
Sure
Sir,
Please make a video on how to protect our off grid system from solar storm.
With due respect Sir please compare the delta inverter with SMA present series Inverter.
And if I compare the Delta inverter with SMA present series inverter it give more features and Benefits.
Also please educate our community with SMA shade fix and opticool techniques
Also please explain about today’s fastest communication technology which is Modbus TCP/Ip provided by SMA
Yes definitely true mr niketji sma is good brand
Hi Niket bhai , this information is collected from SMA Technical date sheet , model no. Is mentioned you can download and cross check ,
I have just done a comparison between 2 make for domestic users below 10kw who has a limited budget yar , for large scale user SMA tripower series is the best , as my company personally use it over other Inverters , I hope I have not offended your feelings in any way , thanks for highlighting your concern , also why does SMA Inverter comes with a Inverter manager for communication?
@@SustainableEveryDay Sir sma new inverter comes with 50 % overloading.
Only STP 60 and SHP 75 comes with Inverter manager as it is designed for commercial and utility plants.
Also, to provide higher power to weight ratio, the control unit provided externally. Which called Inverter manager.
files.sma.de/downloads/STP8-10-3AV-40-DS-en-20.pdf
link to downlod new sma 10kW inverter
Sir i am installing 150kw on grid solar and my service provider is asking that which inverter i want so plz suggest me between these 2 inverters delta or growatt.
Delta
Sir mere ko solar mai career banana hai isme future secure hai kya
Jaipur se hu koi acha institute nahi mil raha
Electrical engineer
Help me
Bhai solar power generation ka kaam is highly secure
Advance Electrical Design & Engineering Institute ,Institute for Electrical Design Training Course , Institute for Design in Substation Design Training, Designing Course for Solar Structure Design , Online Design Training Courses for Electrical System Design, Solar power Plant And Substation Design
C-1, 2nd Floor, Near Nirman Vihar Metro Station, Laxmi Nagar, New Delhi, Delhi 110092
084670 24957
maps.app.goo.gl/vbkgDkm7sweTfVJw9
@@SustainableEveryDay 🙏
Zabardast
Hello sir meri firm ki sales b m khud dekhta hu ...meri poori working yahan online chalti h google promotion s..indiamart and just dial s promotions chalta h...m sales b job karta hu..sir plzzz meri saari baaton ko sunkar plzzz help me sir.....
I hope you can help me
Please help me choose b/w waree , goodwee & Solis 5KW 3 phase inverter on grid....My solar installation will happen this month.. City is Lucknow
I am also based in Lucknow. Did you go ahead with Solar Installation?
Technical ya sales jisme b achha paisa mile m kr skta hu sir and agar aap chaahe toh aap mjhe work dde dena m product bech kr b dikha dunga dusre product k comparison m kr k customer ko apna product bech sakta hu sirr plzzz give me reply
Sir I am interested work in Dubai and I have two year experience
You have to try with over seas job consultant
Sir where does Voltronic Power stands as compared to these benchmark inverters? In Pakistan majorly voltronic Power inverters are used for hybrid systems.
Actually I have not used Voltronic till now
Sir I want to install 3kv grid system at Haryana jind should I go with delta or polycab? And how's the service of delta in haryana jind city?
Go for Luminous और delta... Polycab fail hai
Informative video, keep it up
Hello peoples this info sharing by this persons is wrong . Sma is working from last 35 yrs and they have their proof . nobody can claim their products
Hi Asfak bhai , this information is collected from SMA Technical date sheet , model no. Is mentioned you can download and cross check ,
I have just done a comparison between 2 make for domestic users , for large scale user SMA tripower is the best , as my company personally use it over other Inverters , I hope I have not offended your feelings in any way , thanks for highlighting your concern
@@SustainableEveryDay what is the proof.
That delta data sheet is actual.
Download the sheet & match the data model is RPI-M10A , prove me wrong
10 kw is overkill for most Indian homes mate!
Off gird invter
Hello sir
Sir I send you message on instagram please reply I had a doubt
Please reach me out on LinkedIn , instagram is for photo sharing
@@SustainableEveryDay Hi sir i have a question
I work in indian railways
We have Auxillary transformer at stations and LC gates to step down 25kv to 220v AC supply
We have 4 types of Auxiliary transformer 5kva,10kva,25kva and 100kva as per load at different stations
Sir in the transformer the output voltage is 220v but we get 247v or more at the sockets also the voltage between neutral and earth is 5-10 volts or more and it's never stable . Sir why this occurs and what can be the probable solutions please reply
Hi sir can you help me out what's the issue is
Call me sir I'm from delta
Sure let's connect over LinkedIn
🍉
Sir please Help me🙏
Solar system install krne ke liye स्टेक्चर कैसे बनाते है कोई फॉर्मूला है किया सर जी please मेरी हेल्प करना सर जी
7073434894