Fire door installation video

Поделиться
HTML-код
  • Опубликовано: 25 янв 2016
  • Hinge fire door installation video
  • НаукаНаука

Комментарии • 20

  • @manjunathanagaraju7469
    @manjunathanagaraju7469 5 лет назад +1

    Experts work done!

  • @neilmcmahon805
    @neilmcmahon805 Год назад

    Love the music !!

  • @rogiervantilburg3440
    @rogiervantilburg3440 2 года назад

    Thank you, guys!!

  • @Mickman007
    @Mickman007 Год назад

    Different fire board insulation required these days plus fire mastic both sides.

  • @pmmtb699
    @pmmtb699 Год назад

    That would be miles away from passing these days
    7 years ago wasn’t bad though

  • @SuperJammygit
    @SuperJammygit 3 года назад

    Tell me why is the door lock above the door handle mmm

  • @JonathonNeville
    @JonathonNeville Год назад +1

    Why were the screws hammered in? (Someone else asked this same question, and got no reply.) What are we not understanding?
    Thanks

    • @thrivedru
      @thrivedru Год назад

      I'm wondering the same thing... they also used snips to cut the trim... judging by the language of the title, it may be some cultural difference. We certainly do not do it like this in Canada. The shimming and leveling of the jamb, sure , but not screws and cheap casing. Plus, they dont even show feigning the shims off before fitting he casing. I'd say this is about a 6/10 video
      Edit: it's a fire door, and they're using a hammer drill. So that drywall is probably covering cinder blocks. Hence why they'd have to use a hammer drill to hammer the "screws" into the cement. I watched it twice and realized I wasn't seeing some things the first time.

    • @nemod3338
      @nemod3338 7 месяцев назад +2

      These are hammer in screws. They come with specialy designed plugs. You just hammer them in and can unscrew if needed.

  • @garvielloken3929
    @garvielloken3929 2 года назад

    NOOICE!

  • @googleuser6440
    @googleuser6440 2 года назад +2

    Using a hammer to install the screws? 🤣

  • @christopherjones6607
    @christopherjones6607 3 года назад +3

    No fire mastic over the fire bat ...

    • @JonathonNeville
      @JonathonNeville Год назад

      Is mastic only required where a long duration fire rating is required?

    • @TheJamienelson123
      @TheJamienelson123 Месяц назад

      Depends on the test evidence for the door, would expect minimum of mineral wool and mastic though but the architrave / trim could be a tested method suitable within the assessment

  • @richibalero5109
    @richibalero5109 4 года назад +2

    😂😂😂😂😂😂