Aggregate Impact Value Test in Hindi || Impact Value (Crushing value) test in Site Laboratory
HTML-код
- Опубликовано: 17 апр 2022
- Aggregate Impact Value Test in Hindi || Impact Value (Crushing value) test in Site Laboratory
in this in this video I am telling about how to do the aggregate impact value test inside laboratory the whole process of aggregate impact value test will be explained in this video...
in simple and easy Language.
#impact_value,
#Aggregate_impact_value,
#Crusing_Value
8mm ki rod se tamping karte h sir esko ham
Sorry I know this is a mistake.
@@CivilEngineerShubhamGupta koi nhi sir jo kaam karta h use se mistake' hoti jo nhi karta use kbi mistake nhi Hoti
Big Respect sir ap ny jis tarha step by step samjya hai aur formula lagna sikhya hai kya bat hai sir apki ❤❤
Thank you 😊👍
very simple and easy explained .........thank u so much sir
Mere ko ye test malum nahi tha aapka video dekh ke aaj malum chala kaise karte hai ❤
Bhaiya apki calculation samjane ka tarika bahut accha hai
Knowledge full video thanks
Aapko bahut bahut dhanyawad sir
Dhanyawad sir ji 🙏
Thank you
Nice explanation
Thank you Sir & respect your assistant ❤❤❤❤
So nice of you
Very very nice 👍
Wao very nice sir🤔🤔🤔
Tq very helpful
Good sir💐💐👌
Thank you sir lab work s
Mast bata rahe hai sir
Gajab sir
Grate post sir
Sir jo 12.5 mm se pass 10 mm se retain ho usko oven me 4 hours ke liye dry hone ke liye rakhte hai sir
Helpful ..
Thank u sir ❤
Thanks you sir
Shukriya😇
Thik hai sir ...
Good 👍
Thik hai💯
Sir Very informative But i Have One Question...
Sir 3 Trials K liay Jo Cement Sample Lena Wo 3 Alag Bags Mein Sy Lena Ha Ya 1 E Bag Mein Sy?
Thanks 🙏
Good knowledge thank you sir
So nice of you
Good sir
Thanks bro
Ty
ये टेम्पिंग रॉड हम aiv में यूज नही करते सर
आप बनाते रहिए वीडियो सही है भाई साहब 👍👍
I know but mere paas yhi available tha
Thanks for your feedback
@@CivilEngineerShubhamGupta ya I know
excellent .Good job man
Ek course nikaliye low fees me sir 😊
is code kaun sa hai aggregate k liye?
❤
Sir sare test 10 mm aggregate ke liye hi karte h 20 mm ke liye impact test karke dikhaye plz
Mould ka size kya rahega
Yeh to cube casting ka tamping rad he sir
Yarr taymping rod kitna mm ka hai
Thank you sir ❤❤❤❤❤😂
Note 👉
Tamping road should be used as per is code 2386 part 4 clause 4.2 d which is written as below
•Tamping Rod-A straight metal tamping rod of circular cross-section
10 mm in diameter and 230 mm long, rounded at one end.
•The use of this small tamping road is to exert air from the cup and prevent aggregates coming out from the mould which is small in dimension.
Yes it's was a mistake.
Civing kase karte hai
Bhai mould kahte hai ese
Sir 10mm ka Kabhi test Hota hai
Nice video
But 2386(p-4) ke according tamping rod ki size - 230mm long & 10mm dia hogi.
Aapne crushing ka tamping rod use kiya hai
& balance 0.1 g accuracy ka use hoga
Iska is code kya hoga
Ye jo test kiya tha aggregate 10 mm thi ya 20 mm
20 mm
Name of instrument pls
Use correct tamping rod.. as per is code this tamping rod not acceptable..... Is code says the wait of sample min 350 to 370 gm
Empati 😀😄😁😁
Oven me dried nhi kiya 4 ghante ke liye
Oven mai drai thab hota h jab aggregate gila ho
15
sir soil test ka bhi video dalo sir and cement test ka bhi Quality ke sare test video dalo sir
Sir What is the IS code
Is code 2386 part 4
Iska tamping rood dusra aata hai Bhai ji
Right
Ap to golt dekhaya sir ji
16mm ki tamping rod impact value test me use Nahi Hoti Hai.
Right i know but I don't have any other
@@CivilEngineerShubhamGupta right sir is ky lyea alag hota hai tamping rod 16 mm ki rod concrete or slmp
Your tamping rod is wrong side
Ye wrong method h aiv ka temping rod alag hota hai...cube bharne Wale se temp kar rahe hai...
Right. Bro it was a great.
Tamping gat kiya gya hai sir
Very nice 🙂
Temping ko sidha pakdo
Bhai galat temping rod use kar rahe ho.
Sir but what's the main purpose for doing this test and sir what's the difference between sieve analysis test and impact value test
Sieve analysis for checking size of agg, an एग्रीगेट impact value for checking strength of aggregate
@@CivilEngineerShubhamGupta thank you sir
Temping hi galat hai 10mm chahiye
You used a wrong tamping rod
Yes
Hhj
Tamping nai hota he bhai
Kaise bhai
Tamping Galt h
Bhai glt mt batao jo tum taping glt hai
Is code no. Bataye
IS 2386 part 5
@@shubhmmishra9956 hiii
@@dheerajmishara1551 yes
sir Lab technician ka information dijiye please sir.......
Dear @@dheerajmishara1551 You should have 1:- Good Knowledge about testing (Construction Material:- concrete technology, Cement, Reinforcement, Aggregate-Fine & course Brick, Soil, Earth resistivity Etc.)
2:- good knowledge about lab testing equipment & formates.
Regards
Shubham Mishra
Asst. Manager-civil(QA/QC)
16mm
Sir apka mobile number mil skta hai kya
Good 👍