how to repair automatic pump control

Поделиться
HTML-код
  • Опубликовано: 20 окт 2024

Комментарии • 11

  • @charlesasante1439
    @charlesasante1439 Месяц назад

    Where did you order the replacement
    board?

    • @IT-AEA
      @IT-AEA  26 дней назад

      in the Internet store

  • @dalejones2108
    @dalejones2108 11 месяцев назад

    I see a slotted screw adustment is this for pressure adjustment this thing is not that old?

    • @IT-AEA
      @IT-AEA  11 месяцев назад +1

      this screw serves for venting - air access, pressure is not regulated in these designs

  • @dalejones2108
    @dalejones2108 11 месяцев назад

    Ok how does sense pressure when ball valve closes. The messure current draw?

    • @IT-AEA
      @IT-AEA  11 месяцев назад

      Inside is a spring that compressed and uncompressed under water pressure. Reed switch (magnets) that close or open the contacts on the board

    • @dalejones2108
      @dalejones2108 11 месяцев назад +1

      @@IT-AEA thank you

    • @dalejones2108
      @dalejones2108 11 месяцев назад

      @@IT-AEA are they field adustable For shutoff pressure?

    • @IT-AEA
      @IT-AEA  11 месяцев назад

      Reed switch reacts to the spring. The pressure on the spring is created by the motor. Usually the pressure is 1.5 bar

  • @weilongxia
    @weilongxia 7 месяцев назад

    Manufacture of this controller is my customer😅

    • @IT-AEA
      @IT-AEA  2 месяца назад

      funny