Paano Malaman if Overload na ang Circuit Breaker at Wiring | Clamp Meter Test | Local Electrician

Поделиться
HTML-код
  • Опубликовано: 15 сен 2024
  • #wiring #overload
    #clampmeter #breaker
    Thank You for Watching Guys!
    Please Visit our Channel👇👇👇
    / localelectricianph
    For more Electrical Installation and Controls Video Tutorials.
    FB Page: Electricians Guide
    / localelectricianandmore
    Direct message on our FB Page for other Questions. Thanks!!
    OTHER USEFUL VIDEOS 👇
    24 HOUR CLOCK TIMER SETTING
    • Auto 24 Hour Clock Tim...
    REMOTE CONTROL Switch Wiring | Testing
    • Paano mg wire ng Digit...
    MANUAL OFF AUTO MOTOR CONTROL
    • MANUAL-OFF-AUTO Motor ...
    FLOAT SWITCH wiring and diagram
    • Float Switch wiring an...
    3GANG SWITCH wiring
    • 3 Gang Switch Wiring t...
    HOW TO USE MEGGER / insulation tester
    • HOW to use MEGGER Insu...
    3-WAY SWITCH Wiring Tutorial
    • 3 Way Switch - tagalog...
    WYE DELTA MOTOR CONTROL
    • WYE DELTA STARTER Wiri...
    Stop Start Wiring Control Circuit and Diagram
    • Stop Start Magnetic Co...
    FORWARD REVERSE STEP BY STEP
    • FORWARD REVERSE Motor ...
    On Delay Timer Wiring Diagram
    • ON Delay Timer Diagram...
    FLOATLESS RELAY WIRING
    • Floatless Relay Wiring...
    Stop Start with Overload Relay Connection
    • Magnetic Contactor Sto...
    • Overload Relay ( therm...
    OVERLOAD RELAY Function tutorials. tagalog
    OHMS LAW
    • OHMS LAW - Voltage Cur...
    24 HOUR TIMER FUNCTIONS
    • HOW TO SET 24 HOUR CLO...
    • Multimeter Paano guma...
    How to use MULTIMETER tagalog video
    STOP START w/ INDICATOR LAMP
    • STOP START w/ INDICATO...
    • HOW TO SPLICE A WIRE -...
    How to Splice a Wire video
    MAGNETIC CONTACTOR PARTS AND FUNCTIONS
    • Magnetic Contactor Par...
    VOLTAGE TESTER
    • VOLTAGE TESTER NEON SC...
    HOW TO COMPUTE ELECTRIC BILL
    • Electric Bill Computat...
    7 WAYS TO REDUCE ELECTRIC BILL
    • HOW TO LOWER ELECTRICI...
    POWER FORMULA
    • POWER CURRENT VOLTAGE ...
    HOUSE WIRING TUTORIAL
    • HOUSE WIRING TUTORIAL-...
    PHOTOCELL with Magnetic Contactor
    Wiring/Diagram-street lights
    • PHOTOCELL w/ Magnetic ...
    Magnetic Contactor VS Mechanical Relay
    Uses and Function
    • Magnetic Contactor VS ...
    SUBMETER INSTALLATION
    • SUBMETER INSTALLATION ...
    MECHANICAL RELAY WIRING
    • RELAY WIRING TUTORIAL ...
    Music:
    Tuff Data | Vans in Japan
    No Copyright claim.
    • Video
    Vans in Japan | Four More Weeks
    • Video
    No Copyright Claim
    Seasons - Telecasted
    No Copyright Claim
    • Seasons
    Breeze | Telecasted
    • Breeze TELECASTED 🎼 [ ...
    No Copyright Claim

Комментарии • 122

  • @xelpamintuan3953
    @xelpamintuan3953 2 года назад +3

    GOOD DAY PO SIR BOSSSING! ASK KO PO ANG GENERATOR PO MAY "RATED PKWER 2.8KW AT MAY MAXIMUM POWER 3.1KW" ILANG WATTS PO ANG GENERATOR? tnx po... NICE DEMO PO PAANO GAMITIN ANG CLAMP METER KUNG PAANO KUHANIN ANG AMPERE TNX AGAIN PO GOD BLESS

  • @KataTukuTV
    @KataTukuTV 2 года назад +2

    mabuhay po lahat ng manggagawang pinoy😃✌️

  • @dannyrosales3197
    @dannyrosales3197 Год назад +1

    Salamat po, sa demo,, malaking sa akin at dag dag ka alaman,, ty,😇😇😇

  • @JunPVlog
    @JunPVlog 2 года назад +2

    Nice sharing sir watching here sending full support.. Salamat sa pag share

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад

      Salamat po Sir. Tuloy2 lng po kayo sa pag upload ng quality vids

  • @samuelfernando9877
    @samuelfernando9877 2 года назад +2

    Pa Shout out po watching from Malaysia

  • @jednifsenarlo4786
    @jednifsenarlo4786 2 года назад +3

    You should always consider first the wire size para maiwasan mapunit sa sobrang stress.

  • @leonskiesugetarios2441
    @leonskiesugetarios2441 2 года назад +2

    Paanu nga plA malaman lods👍

  • @digztv-143
    @digztv-143 2 года назад +3

    Good day sir, nice tutorial. Ask ko lang sir Anu ang tamang breaker sa 1.5 hp na water pump?

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад

      Kaya n yan 20 A Sir.

    • @jednifsenarlo4786
      @jednifsenarlo4786 2 года назад +1

      30A breaker and use 5.5mm2 THHN wire kasi motorized na yan.

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад

      FLC x 250%po talaga dapat nyan Sir kaso mahirap mag hanap ng 25A na breaker sa market po..10A po FLC ng 1.5Hp.

    • @digztv-143
      @digztv-143 2 года назад +1

      Ok Sir, iyong service entrance ko Sir THHN #10 kaya pa ba Ng wire kung dagdagan ko ng 20 Ampers para sa water pump?

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад

      #8 po minimum ng service entrance Sir. Ano ano po mga load ng #10 nyo po

  • @EmelioMabilog
    @EmelioMabilog Год назад +2

    Master ano po problrm pag kumukurap kurap ang ilaw at mga appliances nagpalit na po kami mga new breakers.salamat po

  • @arhvinpedir9422
    @arhvinpedir9422 Год назад +3

    Sir pwd po ba mag loose connection sa extension wires? Na nakakabitan ng ilaw, salamat po sa tugon.

  • @anethemia7857
    @anethemia7857 Год назад +2

    Magandang araw jan sir electrician,my konting tanong ako sir.
    My computation ba sir sa pgkuha ng main brkr at branch brkr sir?,yung tamang size ng amper sir sa main at branch.

  • @franciscovargas7173
    @franciscovargas7173 Год назад +3

    Di ba magti trip naman ung breaker kung mag overload sya? So magkaka idea ka kung bkit nagti trip ung breaker, mean may problem, baka nga overload. Para san pa ung breaker?

    • @LocalElectricianPH
      @LocalElectricianPH  Год назад +1

      Yes Sir. Basta po sakto at standard ang wiring method at akma ang sizes ng wire sa ckt breaker..at 80% safety factor max load. Wala po magiging problema Sir.

    • @franciscovargas7173
      @franciscovargas7173 Год назад +2

      @@LocalElectricianPH kaya nga po! Ang tanong kc is paano maiwasan ang overload? Trabaho ng circuit brkr un. Ndi nya papayagan ung overload, magti trip sya. Ayun na! Naiwasan na ung overload. Assuming na tama ung mga breakers and wires.

    • @LocalElectricianPH
      @LocalElectricianPH  Год назад +3

      Yes Sir tama po kayo. Sa demo naman po ay sa mga concious consumers na gusto malaman ang kanilang current load Sir gamit ang clamp meter. Gagana parin po ang breaker as is po. Pra narin po mapatagal ang life span ng cb kasi the more na marami ang load. Example lagpas sa 80% pero d pa yan mg trip. Eh mas bababa ang buhay ng breaker kasi mas iinit po sya.

    • @michaeldollar2225
      @michaeldollar2225 Год назад +1

      Ito sana itatanong ko, buti nag read ako sa comment section, nasagot na agad yung dapat na itatanong ko. Salamat po mga Sir.

    • @LocalElectricianPH
      @LocalElectricianPH  Год назад

      Salamat po

  • @louiesarabia8850
    @louiesarabia8850 Год назад +2

    Paano po ang breaker na 150amp umiinit ang line side patibreaker ng apartmemt..kailanganba talaga ng transformer or pwede po ba palitan lang ng breaker na 250 amp..?sana matugunan niyo po aking tanong...tnx..

    • @LocalElectricianPH
      @LocalElectricianPH  Год назад +2

      Posible sa lose contact yan Sir. Wag basta2 mg palit ng amperahe ng breaker lasi may computation ang wire size at ampere rating po nyan

  • @windylumbab982
    @windylumbab982 Год назад +3

    Boss ano ba setting mo sa clampmetter ..pag magttest ka ng load ? Salamat

  • @gogleaccont3784
    @gogleaccont3784 2 года назад +2

    Good day boss tanong ko lang , pwede ba hindi na gagamit ng Main breaker at maglagay nalang ng Square Box sa Line side para duon nalang itatop ang tatong (2-3) brances ng breaker. Salamat.

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад +2

      Dapat po may main. For additional safety. At make sure d po overloaded ang main line nyo

  • @francisrull7054
    @francisrull7054 Год назад +2

    panu Po mag Megger testing boss gamit Po clamp meter tsaka Po digital multimeter

    • @LocalElectricianPH
      @LocalElectricianPH  Год назад +1

      Pag mag megger po kayo inaulation resistance tester po gamitin nyo Sir.

  • @vahnrondel
    @vahnrondel 9 месяцев назад +1

    tanong lang sir,
    sa analog tester kasi, ramdam na ramdam ang pagkakaiba ng magandang tester tulad ng sanwa versus sa mga mumurahin.
    sa clamp meter ba, ganun din? ano ba ang mgandang basehan bago bilin ang clamp meter?

    • @LocalElectricianPH
      @LocalElectricianPH  9 месяцев назад

      Accuracy lang naman po ng mamatter ang mga branded at d kilala brand sir..importante calibrated at stated f ilan ang tolerance sa kanyang specs.

  • @rogeliobaguio6768
    @rogeliobaguio6768 2 года назад +2

    Ask ko Lang Sir pwed bang mag add Ng breaker Kung mag dag dag tapos sa line side ko ikakabit oh SA load side talaga salamat.

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад +1

      Dependi po f kakayanin pa ng wire o breaker mo ang e dagdag nyo po.

  • @ryanmayo5669
    @ryanmayo5669 2 года назад +2

    First idol sir tanong lang baka alam mo kasi digital tester ko walang fuse ngayun nasa amp ang probe pero nailagay ko sa 220 ngaun pinalitan ko ang nasunog kaso para overload na ang sukat nya

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад

      Mahirap pag pumutok na yang fuse at magkamali ka sa setting lalo na yang mga masyadong mura na tester po..tingnan mo sa loob f merong nasunog na circuit o pyesa

    • @ryanmayo5669
      @ryanmayo5669 2 года назад +1

      @@LocalElectricianPH wala syang fuse sir pero may nasunog na pyesa pinalitan ko na lang din kaso ganun pa din

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад

      Mahirap napo yan maayos lalo nat napaka liit ng pyesa sa ilalim po..sayang naman...try nyo po ilapit sa mga electronics shop.

    • @ryanmayo5669
      @ryanmayo5669 2 года назад +1

      @@LocalElectricianPH pero nagagamit ko pa naman po pang measure ng voltage ohm buzzer accurate naman po doon lang talaga sa amp

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад

      Ahh ok po..atleast gumagana pa..

  • @samdelacerna7518
    @samdelacerna7518 11 месяцев назад +1

    Sir good afternoon...tanong ko lang po sir...sa no. 6 Na drop wire galing sa poste ilan po bang 60 main breaker ang makakaya? Kaya po ba 6 na 60amps. Main breaker at 8 na 40 amps. Na main breaker sir?

    • @LocalElectricianPH
      @LocalElectricianPH  11 месяцев назад

      No.6 aluminum clad isan 40A na main lang yan Sir. No.6 na copper isang 60A na main

  • @eugenes.68
    @eugenes.68 Год назад +1

    Taga saan po kayo?

  • @orlandosudario1045
    @orlandosudario1045 Год назад +2

    Ang 15ahmper Ilan bulb Ang pwdi magamit? Salamat Po.

  • @mp2345
    @mp2345 7 месяцев назад +1

    sir pano mag megger testing?

    • @LocalElectricianPH
      @LocalElectricianPH  7 месяцев назад

      Gamit po kayo neto ruclips.net/video/g2xYmSMy0sA/видео.html

  • @PeterUbongen-me2zs
    @PeterUbongen-me2zs Год назад +1

    Ser parang may ..malakas na pitik poohh ..parang kuryente Po talaga na pitik ..Anu pong Gawin..

    • @LocalElectricianPH
      @LocalElectricianPH  Год назад

      Pa check nyo po sa electrician baka may loose contact mgka sunog pa kayo...dilikado po yan

  • @JoselitoOpena-eb1vp
    @JoselitoOpena-eb1vp 3 месяца назад +1

    Boss .sa akin ang gikan sa meter ay 30A...tapos mag dagdag aku ng breker para sa ref at sa sounds ku..pwede ba 60A..ang ilagay ku.salamat fr,cebu.

    • @LocalElectricianPH
      @LocalElectricianPH  3 месяца назад +1

      20A lng sir 3.5mm wire

    • @JoselitoOpena-eb1vp
      @JoselitoOpena-eb1vp 3 месяца назад

      @@LocalElectricianPH sa akin boss hindi lang aku bibili..mayroon akung na tira dito na 60A. Bawal ba cya ilagay.salamat.

    • @LocalElectricianPH
      @LocalElectricianPH  3 месяца назад

      Kayo po bahala Sir. . Salamat po

  • @ramilhernandez9558
    @ramilhernandez9558 2 года назад +1

    ser.gd ev matanong lng po ser f kng ginamit kong breaker 15 amp.at 2.0 wire meron siyang lod na range at elaw at ginamitan ko ng clamp meter at h di naka abot ng12 amp.ok lng ba yan ser

  • @robertnava3956
    @robertnava3956 Год назад +2

    paano naman idol kong multi tester gamit sa pag check idol?
    saan i seset idol?

    • @LocalElectricianPH
      @LocalElectricianPH  Год назад +1

      D po tayo mka sukat ng ac amperahe sa multitester Sir. Dapat po clamp meter

  • @vincentmaglinte8279
    @vincentmaglinte8279 Год назад +1

    Boss hindi po ba i total yung amps kada wire ? For example Line 1 my 2 amps tapos sa line 2 amps din, hindi ba i total yan?

  • @ramilhernandez9558
    @ramilhernandez9558 2 года назад +1

    ser bumili po ako nga ganyang klasi na clamp meter ser hndi po ba madali masira ser yong wire cord niya ser at yong lalagyan ng wire cord niya yong butas

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад

      Hindi naman po...4 years napo itong sa akin...basta taman setting lng at wag mabasa

  • @WalterWhite-lu3bi
    @WalterWhite-lu3bi Год назад +1

    Boss what if 30amp yung main breaker tapos nag connect ako ng submeter for my freezer only pero 60amp yung breaker na kinonek ko. Okay lang po ba?

    • @LocalElectricianPH
      @LocalElectricianPH  Год назад +1

      20A lng po ilagay nyo Sir. For small appliances..ilang watts po ba freezer nyo

    • @WalterWhite-lu3bi
      @WalterWhite-lu3bi Год назад +1

      @@LocalElectricianPH hindi ko lang po alam. Pero 9cubic chest type inverter sya. 60A breaker lang po kasi avail kaya ginamit ko na. Ano po mangyayari nun?

    • @LocalElectricianPH
      @LocalElectricianPH  Год назад +1

      20 A po yan 9 ft Sir. D yan mag t trip f may problema ref nyo masyado po mataas ang 60A

    • @WalterWhite-lu3bi
      @WalterWhite-lu3bi Год назад +1

      @@LocalElectricianPH ganun po ba. Sige po palitan ko nlang

    • @WalterWhite-lu3bi
      @WalterWhite-lu3bi Год назад

      Thank u boss

  • @marvinbonsato8539
    @marvinbonsato8539 23 часа назад

    Ilang amp ang minimum para hnd ma overload bossing?

    • @LocalElectricianPH
      @LocalElectricianPH  2 часа назад

      Sa 20A na cb dapat di ka lalagpas sa 16A..the lesser the safer kasi may mga voltage drop pa yan at loss contacts

  • @retselasnoz8076
    @retselasnoz8076 2 года назад +1

    pag b electricpan 2 posible b mag overload un

  • @arnolddelacruz5026
    @arnolddelacruz5026 Год назад

    Sir ask lang po ano po possible reason bakit may tunog po o ugong ung mga connection sa junction box

  • @floridyroldan4005
    @floridyroldan4005 2 года назад +1

    paano po mag trouble shoot nyan lods

  • @conradtorres3063
    @conradtorres3063 2 года назад +1

    mgndang araw po sir ask ko lng po bkit po kya umiinit ung meterbase at metro ng kuryente ble my water station po kmi tpos 4 n aircon .75hp ung pinkmtaas the rest po .5 slmat poh..

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад

      Baka po overloaded Sir.

    • @conradtorres3063
      @conradtorres3063 2 года назад +1

      @@LocalElectricianPH ano po dpat gwin o plitan sir f overload nga poh???slmat poh..

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад

      Make sure lng kaya ng main feeder nyo ang mga load nyo po..or baka need napo kayo mg upgrade ng linya

    • @conradtorres3063
      @conradtorres3063 2 года назад +1

      @@LocalElectricianPH pno po b mllman f kya p ng main feeder ang load..cenxa n po sir wla po tlga lam pg dting s mga gnyan..klngan din po b mg plit ng mas mllking wire poh??mrming slmat po ulit...

    • @LocalElectricianPH
      @LocalElectricianPH  2 года назад

      Gamit kayo ng tester gaya ng nasa video po...or alamin nyo lahat ng specs or watts ng bawat load

  • @ramilhernandez9558
    @ramilhernandez9558 2 года назад +1

    ser matànong kulang ser pwdi po ba 2.0 wire sa ranga 15 amp gamit ko ser

  • @rogelmendoza69
    @rogelmendoza69 Год назад

    Bakit nag vibrate ang sircuit breaker