dekhiae hamare yahan Paisa jyada milta hai to use hisab se apne ko kam bhi professional karna padta hai sab ham personal war karte hain jija ka ISI ka aur Har room ka to aap dekh sakte ho samne wale party ke hisab se aap firing kar sakte ho nahin to 2.5 mm mein aapka itna load chal sakta hai
sar abhi kya ho raha hai mere pass ladki kam hai to uske Karan video banane mein let bhi ho raha hai aur ek baat main bhi Indore stadium ka kam liya ho to kafi sara kam hai aur usko jaldi khatm karna isiliye video edit nahin Ho pa raha hai
🙏 Technical Lover Love this video 🙏
Hi sr nice very video 👏🙏
Chini Mutti KE connector is very good INSTALLATION to joint copper and aluminium wire
Nice work done
Thanks sir 👍👍
most welcome
Good job 👍👌
Good
Super sir
Nice sir ❤️❤️❤️👍
thank you
@@kamleshelectrician0
Goodjob
❤🎉
Kamlesh bhai aap ka ghar kee video dalo na aap ka ghar kesa hai dekhna hai plz
Good sir
thank you
Nice
Sir ek video arthing per bhi laen copper plat arthing pr
ok
25 ka MCB lagaye hai phir over load hone pe line break hoo jayega.... 32 ka lagana chahiye tha dp mcb
bro vahan per itna load nahin hai usko bola gaya tha 32 empier ka lekar aana 25 lekar a Gaya isiliye usko raat ko lagana pada jaldi mein
*Sir 2.5 mm finolex wire se ham sare ghar ka load chalye to koi dikkat aayegi kya? Kyo ki ghar me ele. Gyeser freez or do fan etc.. laga huva hai??*
Ya Gyeser ke liye personal wire lagani padegi
dekhiae hamare yahan Paisa jyada milta hai to use hisab se apne ko kam bhi professional karna padta hai sab ham personal war karte hain jija ka ISI ka aur Har room ka to aap dekh sakte ho samne wale party ke hisab se aap firing kar sakte ho nahin to 2.5 mm mein aapka itna load chal sakta hai
@@kamleshelectrician *ok sir thank*
gud sir
thank you
भाई डायग्राम बना के बताया करो
Dono ka baat fumbling ho rahan hai
Kamlesh bhai aap kee shadi ho gayi kya
Fan 2way करणा है point कितना होता है
aapko to switch ke bare mein dekhna hai na to main photo Dala hua hai 6 per kar ka 2 switch ho jaega aapka
MCB DP kyu nahi lagae koe Karan he sir
sar uske yahan MCB DP ke Siva aur lagane ka jagah kuchh nahin hai isiliye SP lagaya Gaya
Kamlesh vayya mujhe Kam chaye vay mujhe Kam pe logi vay
17.10 के bad dubble avaj araha hai
Are bhai video banate ho badme edt me check koro
bhi meter to pass m he tha sida he lga dete wire kru connecter barbad kiya
aluminium wire ko direct MCB ko lagaenge to jal jaega
Achee se tight karne per bhi yesa hoga kya @@kamleshelectrician
Meter se direct line MCB mai. De dete koi problem hai kya
ek problem hai copper wire MCB per dalo aluminium per connector lagao
@@kamleshelectrician thank you sir for reply me 🥰
@@kamleshelectrician okay sir without any fuse direct MCB ko connect koi problem nahi ho ga na
sir ajj kl video bhut din baad a rahi hai koya baat tabiat to theek hai ji
sar abhi kya ho raha hai mere pass ladki kam hai to uske Karan video banane mein let bhi ho raha hai aur ek baat main bhi Indore stadium ka kam liya ho to kafi sara kam hai aur usko jaldi khatm karna isiliye video edit nahin Ho pa raha hai
@@kamleshelectrician theek hai ji
GAdbad hai guru wire ko MCB me lagana se Pahle copper thimble nahi lagana APKO DEKH KAR SABHI SEEKH RAHE HAI TO GALAT LEARN KARENGE , Bhai Sudharo
अपने ॐ गलत हाथ पर लिखवा रखा है ॐ अगर लिखवाना था तो राइट हाथ पर लिखवाना था !
yah baat to Main bhi socha galat ho gaya mere se
to kya karna chahie bataiye bro iska upay
Problam mat bola jau , sir
achcha aap bol rahe ho problem mat bolo fault bolo
@@kamleshelectricianbhai poblem nhi pro blem hota ha or video bohut achi ha👍👍
Kitna paisa lia. Is kaam ka
video dekhe nahin pura last Tak dekhiae ismein bataya Gaya kitne paise liye Ho samne wala
Dekha pura video dekha comment video dekhte dekhte hi kiya tha.. Fir last me bataya 700 lia..
Mare halp karo
kya problem hai
@@kamleshelectrician bol hy ap se
electric short circuit Ho Jane par light off Ho Jati Hai Lekin MCB trip nahin karta kyon?
MCB kharab hoga
Aap.whire.ko.cover.nikala.we.tools.kaya.h