How to Test the Relay in Franklin Electric Control Boxes

Поделиться
HTML-код
  • Опубликовано: 4 мар 2019
  • Chris quickly shows you how to test the relay that comes in Franklin Electric control boxes .33 to 15 HP.
    Subscribe & “Ring the Bell”: bit.ly/2CpXSsv
    Have a question or need help selecting equipment?
    Live chat with us on our website: www.rcworst.com
    Call our experts: 855.329.4519
    Email: Customer.Service@RCWorst.com
    ----------------------------------------------------------------------------------------
    Our Social Media
    Facebook: / rcworst
    Instagram: / rcworstcompany
    Twitter: / rcworst
    LinkedIn: / r-c--worst-&-co--inc-
    ----------------------------------------------------------------------------------------
    We are a distributor of pumps, packaged pumping systems, on-site wastewater treatment equipment, on-site wastewater treatment systems, and custom electrical control panels for water and wastewater applications, water well supplies, drilling supplies, and water treatment equipment.

Комментарии • 53

  • @cantankerouscurmudgeon2225
    @cantankerouscurmudgeon2225 5 лет назад +38

    Here's an idea, why don't show an example of a bad relay along with the good one.
    So some one will know what to look for in a bad one also.

  • @lights80088
    @lights80088 5 лет назад +6

    I have to tell you guys, hands down you have the best channel on these "well" subjects. Thank you for sharing your knowledge.

    • @RCworstwater
      @RCworstwater  5 лет назад

      Thanks!! That's what we strive for!

  • @ThisNorthernLife
    @ThisNorthernLife 4 года назад +3

    Thank you for the help. I bought a new one and compared the test and was put at ease to know it was that vs finding a deeper problem like the actual pump.

  • @Bredddi
    @Bredddi 3 года назад

    got 49 m ohms on CAP and B, trying to find a replacement now. thanks for the video! really!

  • @jamesrooney7689
    @jamesrooney7689 Год назад

    thank you thank you very well explained

  • @alanlevijoki5264
    @alanlevijoki5264 3 года назад +1

    I experienced an interesting problem with the control relay on a 3/4 HP submersible pump. A 1 year old pump started blowing the recommended 10 amp fuses every few weeks. Pin 5-2 measured 4.75 ohms. Run current draw measured with a Fluke clamp on meter was on spec and line voltage was correct though I did not measure transient voltage at start up. Changed the capacitor, no improvement. Installed 15 amp fuses and problem went away for a few months. Installed 20 amp fuses for a test only and they opened. Replaced the controller and returned to recommended fuses. No failures 4 years and counting.

  • @biztrak4436
    @biztrak4436 2 года назад +1

    In this vid, you show a 4.5 to 7.0 for a 230 reading for a 230 V system. My relay is a 27 year old GE 3ARR3. My reading shows 3.73 that after a dozen tries. I just going to buy a new relay but from your vid it seems like I should be getting the 4.5 - 7.0. The GE relay is identical at least with the 5-2-1 poles with the white one you show beside the Franklin control panel. I don't know if you read the comments but enjoy your videos.

    • @tkmad7470
      @tkmad7470 2 года назад

      I have the same relay with the same result. Did you replace yours?

  • @amandozarate8187
    @amandozarate8187 2 месяца назад

    Hola amigo, como funciona el QD RELAY En conjunto con el capacitor, en las bombas sumergibles, en Español. Por favor, me rs muy imteresante rl tema, gracias por la atencion brindada. Saludos desde mexico.

  • @johnhurtme
    @johnhurtme Год назад +1

    If I am getting a .3 reading on that last test between B and L1. Would that indicate replacement?

  • @junk6563
    @junk6563 2 года назад +2

    Please note. The relays are potential start relays. They should be replaced with the correct drop in and drop out voltage! The pump motor builds up back EMF which causes the relay to take the start capacitor out of the circuit. Please advise everyone to replace the relays with the correct drop in and drop out voltage. It's just not a simple relay!

    • @JeffHardie
      @JeffHardie 2 года назад

      Thank you. His videos are very good but a quick explanation like you just did would be great.

  • @Whoreshoer
    @Whoreshoer 3 года назад

    Hi there.... I got 9.8 ohms on a 1.5hp box. And it did not read k ohms on the meter. Any thoughts? Thanks!

  • @LongTran-ys6ze
    @LongTran-ys6ze Год назад

    Could you please provide a video explaining the internal schematic of the relay for 5 HP controller (305213961) and how it works? I am learning about my controller. Thanks

  • @biztrak4436
    @biztrak4436 2 года назад +1

    A quick comment about a previous video you made on testing a start capacitor. What you didn't mention is that even though the ohm check is good that doesn't mean the capacitor is good. My ohm test was fine until I did a mfd check. This is on a 27-year-old 230 VAC shallow well red jacket submersible pump with a start capacitor 64-77 mfd. The mfd test was a failure with the meter jumping around a bit but not even reaching 10 mfd eventually just going back to one. The control box also has a second York 10 mfd in which both the ohms and μF checks out fine. But I have a question about your another vid, so will post another comment. By the way, I have watched almost all of your vids, some several times, and I have learned a lot. I feel like I'm a quasi electrician now.

  • @robtheisen5844
    @robtheisen5844 5 лет назад +2

    Somebody find the easy button from Staples... That was easy! Served up with RC Worst’s Signature Awesome Sauce! What’s next on the agenda for your videos?

    • @RCworstwater
      @RCworstwater  5 лет назад +1

      Chlorine disinfection, PSA on local codes, followed by an exciting series we are putting together with the owner of SumpAlarm.

  • @rogogr5683
    @rogogr5683 3 года назад

    what about the test of the pin cap and the pin L1.?

  • @42billykid
    @42billykid Год назад +1

    water pump stopped working. Did the test and on Cap and terminal B it goes to 15.05 and then bottoms out at 13.0. Does that mean the relay is bad. In the video it says you shouldn't get anything. Thanks so much

  • @pamelaawour1606
    @pamelaawour1606 3 года назад +1

    Hi I have a problem with my water pump it keeps on tripping ,its a pressure kind of water pump how can I go a bout it

  • @billwheeler1213
    @billwheeler1213 3 года назад

    Thanks, & nice shirt! (Wearing almost the same one as I watch) no water but at least I can laugh

  • @israelmacias5680
    @israelmacias5680 5 лет назад

    Podrías agregar subtitulos en español ya que algunos celulares no tienen esa conversión inglés-español por favor saludos cordiales bendiciones!!! Desde Monterrey NL México

  • @danielomarrodriguez8662
    @danielomarrodriguez8662 9 месяцев назад

    Hi. Could I connect a bomb without relay? How can i do it?

  • @sarahlowney8720
    @sarahlowney8720 4 года назад +1

    Do you have a suggestion of where I can purchase the larger relay

    • @RCworstwater
      @RCworstwater  4 года назад

      Give our tech line a call: 855.329.4519

  • @twfoa2329
    @twfoa2329 2 года назад

    We had a 1 hp and our relay isn’t passing the test, so I’m shopping for another one, but finding it difficult to find only the relay (blue). So can we use any other size relay or if I get a new control box, do I definitely need to get another 1 hp, or is it interchangeable for a different hp size?

    • @RCworstwater
      @RCworstwater  2 года назад

      We can sell one to you, give us a call: 855.329.4519

  • @Earthcitizen4609
    @Earthcitizen4609 Год назад

    Is it normally open relay showing 0 cero right

  • @rogogr5683
    @rogogr5683 3 года назад +1

    couid you share the relay diagram?

  • @user-rg6io2yw6w
    @user-rg6io2yw6w Год назад

    Do the start relays have some type of liquid in them mine appears to be leaking at the cap wire connection

    • @RCworstwater
      @RCworstwater  Год назад

      It may have leaked down from the capacitor. Your probably need to replace the whole box

  • @ys-me6bw
    @ys-me6bw 3 года назад

    I have a big black relay that also has a #4 and 6 in it and it is testing 11.5 between 5 and 2 is the relay bad?

    • @RCworstwater
      @RCworstwater  3 года назад

      Give us a call with the control box part # and we can help: 855.329.4519

  • @user-lr1fe4bz7e
    @user-lr1fe4bz7e 2 года назад +1

    Where can I buy it?

  • @rhandymujer3851
    @rhandymujer3851 Год назад

    Hello sir, what is the value of the starting and running capacitor for 3hp goulds submersible pump? Thank you sir

  • @GalacticAdventures69
    @GalacticAdventures69 8 месяцев назад

    I will relay this to my tech friends yes lol

  • @chulew
    @chulew 3 года назад

    Where can I get a replacement relay for p/n 223415905 1/3HP 115V?

    • @RCworstwater
      @RCworstwater  3 года назад

      That part # is not popping up for me. Can you give us a call? 855.329.4519

  • @mikemianrazi4286
    @mikemianrazi4286 5 лет назад +1

    Hi i have a pump its turn and turn on i replaced capacitor but i have still problem the old cap was empty but it was 86-103 uf 220 vac please let me know what should i do

  • @horselover-ix2ig
    @horselover-ix2ig 4 года назад

    I need how to fix it bc my water stopped working but I need to know how to get it working bc rn it’s making a high pitch eeee noise

    • @RCworstwater
      @RCworstwater  4 года назад

      Please give us a call for help troubleshooting: 855.329.4519

    • @thinkingimpaired5663
      @thinkingimpaired5663 4 года назад +1

      So did you find out what was causing your non start? Was it the capacitor instead

  • @user-rg6io2yw6w
    @user-rg6io2yw6w Год назад +1

    Can relay work intermittently?

  • @elsandypants84
    @elsandypants84 2 года назад

    My relay just keeps short cycling very very fast.