Is video me aako pump operating ke sath sath pressure per bhi viewer ka dhyan kheechne ki bahut jaroorat thi...mana ki aapne main line walve band rakha tha taki water supply tank to tank ho ..
Most of the times it is observed that although seperate pumps are installed for sprinkler and riser but both the lines are connected to main hydrant line when the main pump starts water is circulated all over as all the butterfly valves are opened except the drain and recirculation valves.if seperate line from sprinkler pump to sprinkler riser is not provided then what is the use of seperate pumps pl explain.
Dear sir, Please discuss about all components of pump room which is use to water supply in building... I know all but I wants improve my deep education in pump room ...as like 1. hydrant line 2. Sprinklers line 3. Basic line 4. Nrv 5. How to use Jacky pump setting 6. How many types of valve in pump room 7. Butterfly valve 8. How many water tanks and what is capacity to it If you will discuss about it, very good for our
Bhai building area 4790 m2 hair air height 11 floor hai. Iske liye water tank capacity kitni honi chahiye aur pump set kitne hone chahiye. Plz reply me...
Its to simple, all dry rises have a fire pump that will put more enough pressure to run the sprinkler heads up on the top floors. The normal setting pressure is 160 - 180 psi from a smaller pump called as the jockey pump. All pumps have them. So when the jockey pump can't keep up with the demands it signals the fire pump come to alive . So the answer is 130 - 180 psi..
We have only one tank of 2 lack litters, and have 2 sets of diesel engine, main pump and jockey pump. 1 for sprinkler and another for hydrant system. Is that enough?
I need fire fighting equipments total kits such fire pump equipment, fire alaram ,smoke detectors , fire extinguishers,signanes also commor also sir our can please send us your company details
Bai apse gujarish hai k ap ek mic bhi apne pass rakhiye jisse humlog ko barabar se awaz aye Sorry to say but this is true, we are genuinely unable to listen your voice clear next time have a mic for clear voice
सर आपसे निवेदन है एक वीडियो डक्ट, फायर डेंपर, और ए एच यू पर बनाए ।और ये कैसे रिलेट करता है फायर पेनल से । बहुत रिक्वेस्ट है सर ।।। कभी कुछ नहीं मांगा सर आपसे । क्युकी आपने बिना बोले ही बहुत कुछ दिया है । बस इतनी हेल्प करदो सर । 🙏🙏🙏🙏🙏
Bahut hi badhiya video.👍👍🙏🙏
Well explained about fire pump we all need datails videos about fire fighting system...god bless you
Nice information
Nice fire vedo sir
Underground water tank ke bare me kuch bataye
Good description!!👍👍👍
Sob switch auto me rakhna padega na sir.....
This is a very very nice video
Hello sir good morning ji
Video kafi achha hai but camera angle sahi aur hona chahiye tha
Kafi Videos H Pump House Ke ap Dekh Sakte Ho
🙏🙏🙏
Very nice video
Ty ji
Thank you sir
Sir pump room size kitna hoga?
Super
Pl show how pressure switch is set
Nice vdo sir and thankq
Is video me aako pump operating ke sath sath pressure per bhi viewer ka dhyan kheechne ki bahut jaroorat thi...mana ki aapne main line walve band rakha tha taki water supply tank to tank ho ..
More Videos Avilable Sir it's First Time Vidoes No idea in This Way
Very Nice
Vi please make the video in Bangla language
Sprinkler discharge line me inlet - outlet, gong bell etc. Detail me boliye akbar please
Jokipump and main Sprinkle pump ka standard (G.P.M.) kitna hota hai
Hydrent main pump and D.G pupm ka ( G.P.M.)
Kitna hota hai
7:25
Most of the times it is observed that although seperate pumps are installed for sprinkler and riser but both the lines are connected to main hydrant line when the main pump starts water is circulated all over as all the butterfly valves are opened except the drain and recirculation valves.if seperate line from sprinkler pump to sprinkler riser is not provided then what is the use of seperate pumps pl explain.
Please explain setp by step which pumps is auto mode on and auto mode off, with pressure
I know the work of fire fitting I am in Kuwait
All type of pump
Jockey pump suction line should not have a butterfly valve, it must OS&Y type..I hope the next video you may consider right components.
DAYA SHANKAR KUMAR LEADING FIRE MAN JOINE
S.K.M.C MUZAFFARPUR
Good explanation young man. Keep it up
Thanx Boss always Your Spot Dedicated New Era
Sir ik auditor bnna chahta hu too sir kiya krna hoga sir puri detail btaye
Next Live Sessions Me Jude Kabhi Ap Us Time Apko Ache Se Answer De Paunga Dear
Firefighting specialist
Sir aap ka kaha institute hy
Dear sir,
Please discuss about all components of pump room which is use to water supply in building... I know all but I wants improve my deep education in pump room ...as like
1. hydrant line
2. Sprinklers line
3. Basic line
4. Nrv
5. How to use Jacky pump setting
6. How many types of valve in pump room
7. Butterfly valve
8. How many water tanks and what is capacity to it
If you will discuss about it, very good for our
I am not satisfied to your answer because I asked something and your reply sometimes
OK don't worry....
Good job. Thanks
Bhai building area 4790 m2 hair air height 11 floor hai. Iske liye water tank capacity kitni honi chahiye aur pump set kitne hone chahiye. Plz reply me...
1 Sprinkler
2 Jocky
1 Main Pump
2 Jocky
1 Diesel engine ( Emergency Pump)
Tank Capacity 2 Lakh Litter Main Fire Tank
Makeup Tank 50 K Litter
Sir may I use 100mm butterfly valve instead of 100mm gate valves in section and discharge line please inform me
Gate Way Valve & Butter fly valve Me Thoda Different isliye Usko Uske Krne Me Logic H
Sab kuch samjh me aa gya par bhai ji DG pump automatically start nhi kya apne na he usne warning whistle nhi di
D. G Auto Start H Warning Whesel Bhi Deta H Start Hone Se Phale
sir Pump Room me Pump kaise Foundation hota hai ? pl Details video chahiye sir
Can you make a videos on
1)fire diesel pump parts and it parts?
2) fire pump control panel inside components and its function
Visit Chanel Playlist Fire Pump House Avilable all Videos
Nice
Good efforts...keep it up
Thanx Sir
Hii
Presure reduse valve fire me kaha pass use hota hi ji
Diesel engine get not start when you ac power shutdown, so please
Its to simple, all dry rises have a fire pump that will put more enough pressure to run the sprinkler heads up on the top floors. The normal setting pressure is 160 - 180 psi from a smaller pump called as the jockey pump. All pumps have them. So when the jockey pump can't keep up with the demands it signals the fire pump come to alive . So the answer is 130 - 180 psi..
pump room me kon kon se inspection krte hai,or kitne time me...A,B,C Check ka b btaye?
PERV KA KAM .HOTAHE
We have only one tank of 2 lack litters, and have 2 sets of diesel engine, main pump and jockey pump. 1 for sprinkler and another for hydrant system. Is that enough?
Enough
Fire Fighter Vinod Choudhary thank you very much
Can you upload isometric or plan dwg of this pump room thanks
आप लोग जब विडियो बनाते है तो आवाज पर ध्यान दें
I need fire fighting equipments total kits such fire pump equipment, fire alaram ,smoke detectors , fire extinguishers,signanes also commor also sir our can please send us your company details
monorail use and it's capacity which ISMB use ?
Suction line, pump sensing line is not as per NFPA20 or 14., I mean NFPA standard..Please follow and use international standard
Pipe ka section kaise krte hai ki kaun sa dia kha lagega aur kab change Krna hai
Fire Safety Guide line NBC 2016
Bai apse gujarish hai k ap ek mic bhi apne pass rakhiye jisse humlog ko barabar se awaz aye
Sorry to say but this is true, we are genuinely unable to listen your voice clear next time have a mic for clear voice
Site Pe Ye Sab Allowed Nahi H Dear
Good video
Sir Nafs Nagpur kysa hai? Please bataye 🙏🙏🙏
Hiii
Sire hydrant and sprikelar pump ka pressure hold kaishe hoga sir ptane ka kasht kare
Videos Bnaye Hue H Ap Dekh Le
Bhai a video me generator ko auto me chalo, aap auto me nehi chalaya
Other Videos Me Chala Ke Dikhaya Gaya H Ap Dekh Sakte Ho
Please details jockey pump
सर आपसे निवेदन है एक वीडियो डक्ट, फायर डेंपर, और ए एच यू पर बनाए ।और ये कैसे रिलेट करता है फायर पेनल से । बहुत रिक्वेस्ट है सर ।।। कभी कुछ नहीं मांगा सर आपसे । क्युकी आपने बिना बोले ही बहुत कुछ दिया है । बस इतनी हेल्प करदो सर । 🙏🙏🙏🙏🙏
Okk Sure Today Hi Kosis Krunga
@@FireFightervinodkaswan । बहुत शुक्रिया सर । 🙏
Videos Dal Diya H
@@FireFightervinodkaswan thank you so much sir ।।
Welcome Kuch Dout Rah Gaya To Ap Bta Dena Baki New Videos Full information Ka Bna Dunga Jab Time Hoga Sunday Ko
Pani drain karte hai to kaha jata h itna pani
Harwasting Me
Disol engen rpm Kya hai
1705
Sir agar diesel pump nahi hai to diesel pump ki jagah konsa pump karegye
It's Emergency Pump
No Other pump
Aap ache se samjha nahi paa rahe 👍
it's Ok Jaruri Nahi Apko Sab Samjha Paye
Air vijal tank kaise feting karte hai
Sit name
Domestic water and flush water pump ke bare me video upload kijye
Ok Ji
Volume is too low
how to start pump with the system low pressure?
Pressure switch
Sir can anyone make vedio on occupancy load, exits width and exits no based on NBC
Ok
Mara bhi ya sabhi sluice valve ha BFV nahi ha
Good Bro
Bhai audio clarity sahi kro pehle
Okk
He did its best don't criticize,,
Lieser ka meaning Kya Hai Kya ka Hai lieser ka
Watch Full Videos Listion Dear
jay hind sir apna contect no sher me
sir app numbar send karna
Same Name Se Facebook Page H Mera Waha Ajoo Ap Msg Me
Pehle machar maar fir tree ko ratu tota ban or Bhai video ese no chalti
Ram Ram 🙏💐💐💐
Thank you sir
Thanks you sir
Sir firman me female ki hight kitni cahiye
Good video
Female height- 160 cm
Sir 145cm bta rhe h rajasthan nagr palika me jo vekesi niklti h usi me to