This explanatory video encompass important and fundamental topics regarding to automation of electrical systems and digital substations, such as: - SCL Files (SSD, SCD, ICD, CID) - GOOSE and MMS IEC 61850 protocols for horizontal and vertical communications between IEDs and to the supervisory system - Top down engineering process: SCD --> CID - Maintenance procedures and routines for a digital substation - Specific competences required by professional engaged in design, installation, commissioning and maintenance services for an IEC 61850 based digital substation - The importance of IEC 61850 Series for achieving the Smart Grid Congratulations to Niclas Wetterstrand and Andrea Bonetti for sharing such informative, normative and fundamentals information on IEC 61850 applications!
For guidelines on a engineering process for a digital substation, based on International Standards IEC 61850 Series, reference should always be made to IEC TR 61850-90-4:2020: Communication networks and systems for power utility automation - Part 90-4: Network engineering guidelines. 1 - IEC TR 61850-90-4 focuses on engineering a local area network limited to the requirements of IEC 61850-based substation automation. 2 - IEC TR 61850-90-4 also outlines the advantages and disadvantages of different approaches to network topology, redundancy, clock synchronization, etc. so that the network designer can make educated decisions. In addition, this document outlines possible improvements to both substation automation and networking equipment. 3 - IEC TR 61850-90-4 also addresses data transfer over the network in IEC 61850, such as transmitting tripping commands for protection via GOOSE messages, and in particular the multicast data transfer of large volumes of sampled values (SV) from merging units (MUs). 4 - IEC TR 61850-90-4 also considers seamless redundancy to increase the network availability under failure conditions and the high precision clock synchronization that is central to the process bus and synchrophasor operation. 👍 webstore.iec.ch/publication/64801
IEC 61850 Standard Series: A fundamental and internationally agreed pilar of the path towards SmartGrid. 👍
This explanatory video encompass important and fundamental topics regarding to automation of electrical systems and digital substations, such as:
- SCL Files (SSD, SCD, ICD, CID)
- GOOSE and MMS IEC 61850 protocols for horizontal and vertical communications between IEDs and to the supervisory system
- Top down engineering process: SCD --> CID
- Maintenance procedures and routines for a digital substation
- Specific competences required by professional engaged in design, installation, commissioning and maintenance services for an IEC 61850 based digital substation
- The importance of IEC 61850 Series for achieving the Smart Grid
Congratulations to Niclas Wetterstrand and Andrea Bonetti for sharing such informative, normative and fundamentals information on IEC 61850 applications!
Good start up
For guidelines on a engineering process for a digital substation, based on International Standards IEC 61850 Series, reference should always be made to IEC TR 61850-90-4:2020: Communication networks and systems for power utility automation - Part 90-4: Network engineering guidelines.
1 - IEC TR 61850-90-4 focuses on engineering a local area network limited to the requirements of IEC 61850-based substation automation.
2 - IEC TR 61850-90-4 also outlines the advantages and disadvantages of different approaches to network topology, redundancy, clock synchronization, etc. so that the network designer can make educated decisions. In addition, this document outlines possible improvements to both substation automation and networking equipment.
3 - IEC TR 61850-90-4 also addresses data transfer over the network in IEC 61850, such as transmitting tripping commands for protection via GOOSE messages, and in particular the multicast data transfer of large volumes of sampled values (SV) from merging units (MUs).
4 - IEC TR 61850-90-4 also considers seamless redundancy to increase the network availability under failure conditions and the high precision clock synchronization that is central to the process bus and synchrophasor operation. 👍
webstore.iec.ch/publication/64801